- Dual Beam NDIR technology is used to measure CO2 concentration
- Audible Alarm
- Data Logging with SD Card
- RS485 Communication Interface
- Rechargeable Battery
-
Feature- 4-in-1 Monitor PM2.5, CO2, temperature & humidity via RS-485 at the same time.
- High Brightness LED Easily recognize measuring types and values.
- 6-segment CO2 Emoticon As the local situation and refer to CO2 indication standards to transfer the suitable emoticon
- 6-segment PMV Indication Refer to PMV indication to display the real-time body sensing.
- Bargain Set eYc Multifunction PM2.5 Indoor Air Quality Monitor ( type : eYc TGP03 )
-
Features- Measuring input type : DC current / DC voltage
- More output type:Analog output / Relay / RS-485
- Extraction of square root(Input : voltage, current)
- Option RS-485 communication function can do 10-point linear calibration function
- Signal isolation, preventing noise, filtering function : Provide safe and stable measuring
- Power supply : AC 85 .. 253 V, 50 ... 60 Hz;Auxiliary supply output(DC 18 ... 26 V / 50 mA ) : Use for 2-wire & 3-wire transmitter
- User-friendly, interactive operation interface
- Panel installation, high light red LED display panel, 14.1 mm height of character, 5 digits, -9.9.9.9 ... +9.9.9.9.9, 7-segment display
- Programmable, high safety & stability, fire-proof case, moisture-proof cover
- Plug-in installation design for easy maintenance
-
Features- High accuracy ±0.1% F.S. ±1 digit
- 2" LCD display, 5-digit display, decimal point configurable.
- Input signals: Current / Voltage
- Output signals: Current / Voltage / Relay / RS-485
- Power supply: AC 90 ... 250 V / DC 24 V
- Auxiliary power: DC 18 ... 26 V / 50 mA
- Square root function for analog signals
- Relay output can be configured for corresponding action modes (Hi / Lo), hysteresis, delay time, and reset delay.
- The linear interpolation function enables the adjustment of non-linear analog input.
-
Features- High accuracy ±0.1% F.S. ±1 digit
- 2" LCD display, Instantaneous flow : 5-digit, Cumulative flow : 8-digit, decimal point configurable.
- Input signals: Current / Voltage / Frequency / Pulse
- Output signals: Current / Voltage / Relay / RS-485
- Power supply: AC 90 ... 250 V / DC 24 V
- Auxiliary power: DC 18 ... 26 V / 50 mA
- Square root function for analog signals
- Relay output can be configured for corresponding action modes (Hi / Lo), hysteresis, delay time, and reset delay.
- The linear interpolation function enables the adjustment of non-linear analog input.
-
Features- LED display : Instantaneous flow : 5-digit, Cumulative flow : 8-digit, accuracy ±0.2% F.S.
- Temperature and pressure compensation : Utilizes temperature and pressure measurements for precise density compensation and high accuracy flow calculations, with built-in formulas for various applications.
- RS-485 communication support : Adopts the standard Modbus RTU communication protocol.
- Auxiliary power supply : Provides two sets of DC 24V power supplies to simplify field wiring.
- Isolation design : Ensures mutual isolation between input, output, power, and communication interfaces.
-
Features- Measuring input type : DC current / DC voltage
- Multiple output type : RELAY / RS-485 (Option)
- Filtering function, provide safe and stable measuring
- Power supply : AC 90 ... 250 V / 50 ... 60 Hz, DC 24 V±10% Auxiliary supply output (DC 18 ... 26 V / 50 mA), use for 2-wire transmitter
- Panel installation, high light red LED display panel, 14.1 mm height of character, 4 digits(-1999 ... +9999), 7-segment display
- Programmable, high safety & stability, fire-proof case, moisture-proof cover
- Plug-in installation design for easy maintenance
-
Features- Precise Measurement : Utilizes a unique Venturi tube structure
- 2″ LCD Screen : Easily configurable with buttons
- Display Features : Shows instant and cumulative measurements; screen rotates 90 degrees for easy viewing
- Multiple Pipe Diameters Available : (DN15 / DN25 / DN40 / DN50) for easy installation
- Accuracy : ±2.0% F.S., pipeline withstand pressure of 16 bar
- Multiple Outputs: Analog output / Relay / RS-485
-
Features- Non-contact measurement.
- Suitable for flow inspection.
- Work with clamp-on sensors.
- Velocity range : 0 ... ±10 m/s
- Pipe size : DN15 ... DN6000 mm
- Liquid temperature : -30 ... 160°C
- Accuracy : ±1%
- Liquid type : Water, sea water, waste water, alcohol, beer, various kinds of oil etc which can conduct ultrasound single uniform liquid