    • Measures temperature range of -40°C to +125°C (-40°F to +257°F)Lascar
    • Stores over 250,000 readings
    • Logging rates between 2 seconds and 1 hour
    • On screen menu and graphing to start, stop, review and restart the logger in the field
    • Triggered logging mode to start recording data once a user defined level is met
    • High contrast, greyscale, backlit, graphic LCD screen to denote status and alarm level
    • User-programmable audible alarm thresholds with highly visible confidence/alarm LEDs
    • EasyLog software available as a free download
     
  • Features
    • Compatible with K, J and T-type with miniature thermocouple plug connection
    • Stores over 250,000 readings
    • EasyLog software available as a free download
    • Logging rates between 2 seconds and 1 hour
    • Supplied with 1.5m K-type thermocouple with 0 to 200°C (32 to 392°F)
    • Immediate, delayed, push-button or temperature triggered start mode
     
  • Features
    • Compatible with K, J and T-type with miniature thermocouple plug connection
    • Stores over 250,000 readings
    • EasyLog software available as a free download
    • Logging rates between 2 seconds and 1 hour
    • Supplied with 1.5m K-type thermocouple with 0 to 200°C (32 to 392°F)
    • Immediate, delayed, push-button or temperature triggered start mode
     
  • Features
    • -30 to 80°C (-22 to +176°F) measurement range
    • Stores over 250,000 readings
    • Logging rates between 10 seconds and 1 hour
    • On screen menu and graphing to start, stop, review and restart the logger in the field
    • Triggered logging mode to start recording data once a user defined level is met
    • User-programmable audible alarm thresholds with highly visible confidence/alarm LEDs
     
  • Features
    • 3 data loggers for monitoring Chilled Goods, Frozen Goods and Ripening Goods
    • No set-up required. One button press-to-start logging
    • Pre-configured with appropriate sample rates and alarm thresholds for each application
    • Reusable with 12+ months battery life
    • Various export options including PDF, Microsoft Excel and JPEG
     
  • Features
    • 3 data loggers for monitoring Chilled Goods, Frozen Goods and Ripening Goods
    • No set-up required. One button press-to-start logging
    • Pre-configured with appropriate sample rates and alarm thresholds for each application
    • Reusable with 12+ months battery life
    • Various export options including PDF, Microsoft Excel and JPEG
     
  • Features
    • 3 data loggers for monitoring Chilled Goods, Frozen Goods and Ripening Goods
    • No set-up required. One button press-to-start logging
    • Pre-configured with appropriate sample rates and alarm thresholds for each application
    • Reusable with 12+ months battery life
    • Various export options including PDF, Microsoft Excel and JPEG
     
  • Features
    • -40 to +125°C (-40 to +257°F) measurement range
    • Stores over 32,000 readings
    • EasyLog software available as a free download
    • Logging rates between 1 second and 12 hour
    • Immediate, delayed and push-to-start logging
    • User-programmable alarm thresholds
     
  • Features
    • -40 to +125°C (-40 to +257°F) measurement range
    • Stores over 32,000 readings
    • EasyLog software available as a free download
    • Logging rates between 1 second and 12 hour
    • Immediate, delayed and push-to-start logging
    • User-programmable alarm thresholds
     
  • Features
    • Compatible with K, J and T-tyoe thermocouple with miniature thermocouple plug connection
    • Stores over 32,000 readings
    • Logging rates between 1 second and 12 hours
    • Immediate and delayed logging start
    • EasyLog software available as a free download
    • Supplied with 1.5m K-type thermocouple probe with 0 to 200°C (32 to 392°F) measurement range
     
  • Features
    • Compatible with K, J and T-type thermocouple with miniature thermocouple plug connection
    • Stores over 32,000 readings
    • Logging rates between 1 second and 12 hours
    • Immediate and delayed logging start
    • EasyLog software available as a free download
    • Supplied with 1.5m K-type thermocouple probe with 0 to 200°C (32 to 392°F) measurement range
     
  • Features
    • -10 to +50°C (-14 to +122°F) measurement range
    • Stores over 4,000 readings
    • EasyLog software available as a free download
    • 30 minutes logging rate
    • Immediate and delayed logging start
    • User-programmable alarm thresholds
     
  • Features
    • -20 to +60°C (-4 to +140°F) measurement range
    • Stores over 32,000 readings
    • EasyLog software available as a free download
    • Logging rates between 2 seconds and 1 hour
    • Immediate and delayed logging start
    • User-programmable alarm thresholds
    • Stainless steel (316 grade) case
  • Features
    • -40 to +125°C (-40 to +257°F) measurement range
    • Stores over 32,000 readings
    • EasyLog software available as a free download
    • Logging rates between 2 seconds and 1 hour
    • Immediate and delayed logging start
    • User-programmable alarm thresholds
    • Stainless steel (316 grade) case
     
  • Features
    • -35 to +80°C (-31 to +176°F) measurement range
    • Stores over 16,000 readings
    • EasyLog software available as a free download
    • Logging rates between 2 seconds and 1 hour
    • Immediate and delayed logging start
    • User-programmable alarm thresholds
    • Status indication via red/green and amber LEDs
     
  • Features
    • -35 to +80°C (-31 to +176°F) measurement range
    • Stores over 16,000 readings
    • EasyLog software available as a free download
    • Logging rates between 2 seconds and 1 hour
    • Immediate and delayed logging start
    • User-programmable alarm thresholds
    • Status indication via red/green and amber LEDs
     
  • Features
    • Stainless Steel Sensor
    • Nominal pressure: 0 ...4 mH2O up to 0...200 mH2O
    • Accuracy: 0.1 % FSO
    • Diameter 35 mm
    • Cable and sensor section detachable
    • Thermal error in compensated range -20...70°C: 0.2 FSO TC 0.02% FSO/10K 0,02 % FSO / 10K
    • High Accuracy
    • Communication connection
    • turn-down 1:10
    Optional Features
    • IS-version (Ex ia = intrinsically safe for gases and dusts)
    • SIL 2 application according to IEC 61508 / IEC 61511
    • Different electrical connections
    • Customer specific versions e.g. special pressure range
    Areas of Application
    • Mechanical and Plant Engineering
    • Energy Industry
    • Environmental Industry
  • Features
    • Stainless Steel Sensor
    • Nominal pressure: 0 ... 400 mbar up to 0 ... 40 bar
    • Accuracy: 0.1 % FSO
    • Thermal error in compensated range -20 … 80 °C: 0.2 % FSO TC 0.02 % FSO / 10 K
    • Turn-down 1:10
    • Communication interface for adjusting of offset, span and damping
    Optional Features
    • IS-version (Ex ia = intrinsically safe for gases and dusts)
    • Adjustment of nominal pressure gauges (factory-provided)
    Areas of Application
    • Chemical Industry
    • Environmental Industry
  • Features
    • Nominal pressure: 0 ... 400 mbar up to 0 ... 60 bar
    • Accuracy: 0.5 % FSO
    • Pressure port G 3/4" flush
    • Ceramic Sensor, Plant And Mechanical Engineering
    Optional Features
    • IS-version (only for 4... 20 mA / 2-wire): Ex ia = intrinsically safe for gases and dusts
    • SIL 2 application according to IEC 61508 / IEC 61511
    • Pressure port PVDF for aggressive media
    • Different electrical and mechanical connections
    • Customer specific versions
    Areas of Application
    • Mechanical and Plant Engineering
    • Energy Industry
    • Medical Technology
    • Environmental Industry
  • Features
    • Nominal pressure: 0 ... 40 mbar up to 0 ... 20 bar
    • Accuracy: 0.35 % (opt. 0.25 %) FSO
    • Pressure port G 1 1/2" for pasty and polluted media
    • Ceramic Sensor
    Optional Features
    • IS-version (Ex ia = intrinsically for gases and dusts)
    • Pressure port PVDF for aggressive media
    • Diaphragm pure ceramic (99,9 % Al2O3)
    • Customer specific versions
    Areas of Application
    • Mechanical and plant engineering
    • Laboratory
    • Environmental Industry
  • Features
    • Stainless Steel Sensor
    • Nominal pressure: 0 ... 1 mH2O up to 0 ... 100 mH2O
    • Accuracy: 0.35 % (opt. 0.25 %) FSO
    • Diameter 35 mm
    • Cable and sensor section detachable
    • Excellent linearity
    • Small thermal effect
    • Integrated lightning protection and increased over voltage protection; 8 kA gas discharge tube (8/20 μsec); 4 kV surge l-l/l-e according to EN61000-4-5
    Optional Features
    • SIL 2 (safety integrity level) according to IEC 61508 / 61511
    • different kinds of cable and elastomeres
    • customer specific versions e.g. special pressure ranges
    Areas of Application
    • Energy Industry
    • Environmental Industry
  • Features
    • Stainless Steel Sensor
    • Nominal pressure range from 0 ... 1 mH2O up to 0 ... 250 mH2O
    • Accuracy: 0.35 % (opt. 0.25% / 0.1 %) FSO
    • Diameter 35 mm
    • Cable and sensor section detachable
    • Excellent long term stability
    • High accuracy
    Optional Features
    • IS-version (Ex ia = intrinsically safe for gas and dust)
    • SIL 2 (Safety integrity level)
    • Customer specific versions
    • Mounting accessories as cable gland and terminal clamp of stainless steel
    • Different kinds of cables
    • Different kinds of seal materials
    Areas of Application
    • Energy Industry
    • Environmental Industry
     
  • Features
    • Stainless Steel Sensor
    • Nominal pressure range from 0 ... 4 mH2O up to 0 ... 200 mH2O
    • Accuracy: 0.1 % FSO
    • Diameter 35 mm
    • Cable and sensor section detachable
    • Thermal error in compensated range -20...70°C: 0.2 FSO TC 0.02% FSO/10K 0,02 % FSO / 10K
    • High accuracy
    • Communication connection
    • Turn-down 1:10
    Optional Features
    • IS-version (Ex ia = intrinsically safe for gas and dust)
    • Mounting accessories as cable gland and terminal clamp in stainless steel
    • Different kinds of cables
    • Different kinds of seal materials
    Areas of Application
    • Energy Industry
    • Environmental Industry
  • Features
    • Nominal pressure: 0 ... 1 mH2O up to 0 ... 250 mH2O
    • Nominal temperature from 0 ... 30 °C up to 0 ... 70 °C
    • Accuracy: 0.35 % (opt. 0.25 %) FSO
    • Diameter 26.5 mm
    • Separate output signals for pressure and temperature ranges
    • Easy handling
    • low maintenance and wiring costs
    Optional Features
    • Drinking water certificate acc. to DVGW and KTW
    • Different kinds of cables
    • Different kinds of elastomers
    • Customer specific versions
    Areas of Application
    • Energy Industry
    • Environmental Industry
  • Features
    • Stainless Steel Sensor, Stainless Steel Probe
    • Nominal pressure: 0 ... 1 mH2O up to 0 ... 250 mH2
    • Accuracy: 0.35 % (opt. 0.25% / 0.1 %) FSO
    • Diameter 26.5 mm
    • Small thermal effect
    • Excellent long term stability
    • High Accuracy
  • Features
    • Nominal pressure: 0 ... 4 mH2O up to 0 ... 200 mH2O
    • Accuracy: 0,1 % FSO
    • Diameter 26,5 mm
    • Small thermal effect
    • Excellent accuracy
    • Excellent long term stability
    Optional Features
    • IS-version (Ex ia = intrinsically safe for gas and dust)
    • Drinking water certificate according to DVGW and KTW
    • Different kinds of cables
    • Different kinds of seal materials
    Areas of Application
    • Energy Industry
    • Oil and Gas Industry
    • Environmental Industry
  • Features
    • Stainless Steel Sensor
    • Nominal pressure: 0 ... 1 mH2O up to 0 ... 250 mH2O
    • Accuracy: 0.35 % (opt. 0.25 %) FSO
    • Diameter 19 mm for cramped areas e.g. 1" observation well
    • Small thermal effect
    • Excellent linearity
    • Excellent long term stability
    Optional Features
    • Different kinds of cable
    • Customer specific versions e.g. special pressure ranges
    Areas of Applications
    • Energy Industry
    • Environmental Industry
  • Features
    • Ceramic Sensor
    • Nominal pressure: 0 ... 40 cmH2O up to 0 ... 100 mH2O
    • Accuracy: 0.35 % (opt. 0.25 %) FSO
    • Diameter 45 mm
    • Cable and sensor section detachable
    • Chemical resistance
    • Housing PP-HT
    • Integrated lightning protection and increased overvoltage protection; 8 kA gas discharge tube (8/20 μsec); 4 kV surge l-l/l-e according to EN61000-4-5
    Optional Features
    • Cable protection (on request)
    • Diaphragm pure ceramic (99,9 % AI2O3)
    • Different kinds of cables
    • Different kinds of elastomeres
    Areas of Application
    • Chemical Industry
    • Environmental Industry
  • Features
    • High Purity Ceramic Sensor
    • Nominal pressure: 0 ... 40 cmH2O up to 0 ... 100 mH2O
    • Accuracy: 0.35 % (opt. 0.25 %) FSO
    • Diameter 45 mm
    • Chemical resistance
    • High over pressure capability
    • Pure ceramic sensor
    • Especially for tank level measurement of viscous and aggressive media
    • Housing material PP-HT or PVDF
    • Diaphragm ceramics Al2O3 (99.9 %)
    Optional Features
    • Different kinds of cable and seal materials
    • Prepared for mounting with pipe
    Areas of Application
    • Chemical Industry
    • Environmental Industry
  • Features
    • Ceramic Sensor
    • Nominal pressure: 0 ... 1 mH2O up to 0 ... 100 mH2O
    • Accuracy: 0.35 % (opt. 0.25 %) FSO
    • Diameter 35mm
    • Diaphragm ceramics Al2O3 (99.9 %)
    • Cable and sensor section detachable
    • Excellent long term stability
    • Integrated lightning protection 8 kA gas discharge tube (8/20µsec); 4 kV surge l-l/l-e according to EN61000-4-5
    Optional Features
    • Mounting accessories
    • Different kinds of elastomer
    • Customer specific versions e. g. special pressure ranges
    Areas of Application
    • Chemical Industry
    • Environmental Industry
  • Features
    • Nominal pressure: 0 ... 4 mH2O up to 0 ... 100 mH2O
    • Accuracy: 0.5 % FSO
    • Diameter 35 mm
    • Excellent long term stability
    • Easy handling
    Optional Features
    • SIL 2 (safety integrity level) according to IEC 61508 / IEC 61511
    • Different kinds of cables and elastomeres
    • Customer specific version e.g. special pressure ranges
    Areas of Application
    • Chemical Industry
    • Environmental Industry
  • Features
    • Ceramic Sensor, Flush, Plastic Probe
    • Nominal pressure: from 0 ... 6 mH2O up to 0 ... 200 mH2O
    • Diameter 21 mm
    • Excellent linearity
    • Excellent long term stability
    • Accuracy: 0,5% FSO
    • Suitable for hydrostatic level measurement e.g. 3/4" pipes
    Optional Features
    • Different cable materials
    • Customer specific versions, e.g. special pressure rang
    Areas of Applications
    • Chemical Industry
    • Environmental Industry
    • Ceramic Sensor, Probe
    • Nominal pressure range from 0 ... 1 mH2O up to 0 ... 100 mH2O
    • Accuracy according to IEC 60770: 0.25 % FSO
     
  • Features
    • Nominal pressure: 0 ... 60 cmH2O up to 0 ... 200 mH2O
    • Accuracy: 0.1 % FSO
    • Shipping approvals: American Bureau of Shipping (ABS), Bureau Veritas (BV), China Classification Society (CCS), Det Norske Veritas (DNV), Germanischer Lloyd (GL), Lloyd's Register (LR)
    • Diameter 39.5 mm
    • HART®-communication (setting of offset,span and damping)
    • High overpressure capability
    • High long term stability
    Optional Features
    • IS-version; Ex ia = intrinsically safe for gases and dusts
    • Diaphragm 99,9 % AI2O3
    • Different housing materials (stainless steel, CuNiFe)
    • Screw-in and flange version
    • Accessories e.g. assembling and probe flange, mounting clamp
    Areas of Application
    • Marine Industry
    • Shipbuilding/ Offshore Industry
  • Features
    • Nominal pressure: from 0 ... 40 cmH2O up to 0 ... 200 mH2O
    • Diameter 39.5 mm
    • LR-certificate (Lloyd´s Register)
    • DNV ▪ GL Approval (Det Norske Veritas ▪ Germanischer Lloyd)
    • ABS-certificate (American Bureau of Shipping)
    • CCS-certificate (China Classification Society)
    • High overpressure resistanc
    • High long-term stability
    Optional Features
    • Diaphragm Al2O3 99.9 %
    • Different housing materials (stainless steel, CuNiFe)
    • IS-version, Ex ia = intrinsically safe for gas
    • Screw-in and flange version
    • Accessories e.g. assembling and probe flange, mounting clamp
    Areas of Application
    • Water Industry
    • Shipbuilding/ Offshore Industry
  • Features
    • Nominal pressure: from 0 ... 4 mH2O up to 0 ... 100 mH2O
    • Acuracy: 0,35 % FSO
    • Diameter 22 mm
    • Excellent long term stability
    • Highly appropriated for wastewater, sludge and viscous media
    Optional Features
    • Diaphragm ceramics 99,9% Al2O3 (on request)
    • IS-version (in preparation), Ex ia = intrinsically safe for gases and dust
    • Mounting with stainless steel tube
    • Different kinds of cable
    • Different kinds of elastomer
    Areas of Application
    • Chemical Industry
    • Energy Industry
    • Environmental Industry
Go to Top