  • Features
    • A measuring instrument for all climate-related parameters
    • Smart, intuitive measurement programs including HVAC grid measurement as per EN ISO 12599 and ASHRAE 111, PMV/PPD and turbulence as per EN ISO 7730 and ASHRAE 55
    • High-precision, location-independent and integrated differential pressure sensor
    • Extendible with a wide range of probes
    • Analytical software for creating professional reports and measurement data management
    • Digital probes eliminate any additional measurement uncertainty of the measuring instrument
  • Features
    • Simple, fast and particularly precise temperature measurement with NTC or Pt100 probes (optionally available)
    • Fast in-app configuration, graph history, second screen and measurement data memory in the testo Smart App
    • HACCP-compliant, certified according to EN 13485 for use in the food sector
    • High-precision measurement results and high system accuracy with digital Pt100 sensors (calibration without measuring instrument)
       
  • Features
    • Pressure range: up to 1,000 psi (70 bar)
    • Dual stage piston: Higher pressure with less effort
    • Multi-position versatility for on-site use
    • Lever pressurization: Efficient and quick stabilization
    • Portable: Weighs 3.5 lb (1.6 kg)
    • Low maintenance
         
  • Features
    • Pressure range: up to 10,000 psi (700 bar)
    • Dual stage piston: Higher pressure with less effort
    • Multi-position versatility for on-site use
    • Lever pressurization: Efficient and quick stabilization
    • Portable: Weighs 4.19 lb (1.9 kg)
    • High durability with low maintenance
         
  • Features
    • Extremely high sensitivity of ˂3g/a enables detection of even the smallest leaks
    • Visual and acoustic alarm for optimum leakage detection
    • Permanent sensor check, ensuring that your work is both safe and fast
    • Earplug connection for safe leakage detection in loud environments
  • Features
    • Extremely high sensitivity of ˂3g/a enables detection of even the smallest leaks
    • Visual and acoustic alarm for optimum leakage detection
    • Permanent sensor check, ensuring that your work is both safe and fast
    • Earplug connection for safe leakage detection in loud environments
  • Features
    • ATEX approval (94/9/EC)
    • ppm and vol.% display
    • Flexible probe for inaccessible areas
    • 3 different types of gas can be detected: methane, propane and hydrogen
  • Features
    • CNC processed casing, rigid and durable
    • Washable coarse air filter, easy to maintain
    • Panasonic compressor, CFC free refrigerant
    • Vibration proof tube system
    • Enhanced coil, longer lifetime
    • Support external pump, RS485
    • Class F fan motor, Low/High Speed
    • Auto-restart, timer on/off, defrost, RH offset etc
    • Lack/ Wrong Phase protection, lo pressure protection etc.
  • Features
    • Non-contact measurement.
    • Suitable for flow inspection.
    • Work with clamp-on sensors.
      Specification
    • Velocity range : 0 ... ±10 m/s
    • Pipe size : DN15 ... DN6000 mm
    • Liquid temperature : -30 ... 160°C
    • Accuracy : ±1%
    • Liquid type : Water, sea water, waste water, alcohol, beer, various kinds of oil etc which can conduct ultrasound single uniform liquid
  • Features
    • High accuracy ±0.1% F.S. ±1 digit
    • 2" LCD display, Instantaneous flow : 5-digit, Cumulative flow : 8-digit, decimal point configurable.
    • Input signals: Current / Voltage / Frequency / Pulse
    • Output signals: Current / Voltage / Relay / RS-485
    • Power supply: AC 90 ... 250 V / DC 24 V
    • Auxiliary power: DC 18 ... 26 V / 50 mA
    • Square root function for analog signals
    • Relay output can be configured for corresponding action modes (Hi / Lo), hysteresis, delay time, and reset delay.
    • The linear interpolation function enables the adjustment of non-linear analog input.
  • Features
    • LED display : Instantaneous flow : 5-digit, Cumulative flow : 8-digit, accuracy ±0.2% F.S.
    • Temperature and pressure compensation : Utilizes temperature and pressure measurements for precise density compensation and high accuracy flow calculations, with built-in formulas for various applications.
    • RS-485 communication support : Adopts the standard Modbus RTU communication protocol.
    • Auxiliary power supply : Provides two sets of DC 24V power supplies to simplify field wiring.
    • Isolation design : Ensures mutual isolation between input, output, power, and communication interfaces.
  • Features
    • Measuring input type : DC current / DC voltage
    • Multiple output type : RELAY / RS-485 (Option)
    • Filtering function, provide safe and stable measuring
    • Power supply : AC 90 ... 250 V / 50 ... 60 Hz, DC 24 V±10% Auxiliary supply output (DC 18 ... 26 V / 50 mA), use for 2-wire transmitter
    • Panel installation, high light red LED display panel, 14.1 mm height of character, 4 digits(-1999 ... +9999), 7-segment display
    • Programmable, high safety & stability, fire-proof case, moisture-proof cover
    • Plug-in installation design for easy maintenance
  • Features
    • Measuring input type : DC current / DC voltage
    • More output type:Analog output / Relay / RS-485
    • Extraction of square root(Input : voltage, current)
    • Option RS-485 communication function can do 10-point linear calibration function
    • Signal isolation, preventing noise, filtering function : Provide safe and stable measuring
    • Power supply : AC 85 .. 253 V, 50 ... 60 Hz;Auxiliary supply output(DC 18 ... 26 V / 50 mA ) : Use for 2-wire & 3-wire transmitter
    • User-friendly, interactive operation interface
    • Panel installation, high light red LED display panel, 14.1 mm height of character, 5 digits, -9.9.9.9 ... +9.9.9.9.9, 7-segment display
    • Programmable, high safety & stability, fire-proof case, moisture-proof cover
    • Plug-in installation design for easy maintenance
  • Features
    • High accuracy ±0.1% F.S. ±1 digit
    • 2" LCD display, 5-digit display, decimal point configurable.
    • Input signals: Current / Voltage
    • Output signals: Current / Voltage / Relay / RS-485
    • Power supply: AC 90 ... 250 V / DC 24 V
    • Auxiliary power: DC 18 ... 26 V / 50 mA
    • Square root function for analog signals
    • Relay output can be configured for corresponding action modes (Hi / Lo), hysteresis, delay time, and reset delay.
    • The linear interpolation function enables the adjustment of non-linear analog input.
  • Features
    • Volume flow hood weighing less than 2.9 kg
    • Volume flow hood for larger swirl outlets for measuring volume flow, temperature and relative humidity
    • Volume flow straightener for precise measurements at swirl outlets
    • Smartphone/tablet as a second display per App
    • App for creating on-site reports
  • Features
    • Rugged and durable
    • Explosion-proof circuit design, safe and reliable
    • Multiple security protection
    • Simultaneous measurement of multiple gases, multiple numerical display
    • Large screen display, flexible detection system, multiple filtering devices
    • Powerful function, more user-friendly operation
  • Features
    • Quickly configure, start and stop tests on the 1555 remotely, a safe distance away from any operating, energized equipment, using Fluke Connect® and a smart phone
    • Real time trending gives you easy-to-see visual cues, rather than hard to read, rapidly changing values
    • Report creation using Fluke Connect desktop saves time and makes test results easier to understand
    • Fluke Connect saves test results to the cloud for analysis and preventive maintenance
  • Features
    • 3- and 4-pole Fall-of-Potential, earth resistance loop testing
    • 4-pole Soil Resistivity testing
    • Selective earth ground rod testing using 1 clamp
    • Stakeless earth ground rod testing using 2 clamps
    • IP56 rated for outdoor use
    • Rugged carrying case
    • USB data storage and transfer
  • Features
    • Includes "Insulation Pre-test" that detects when appliances are connected to the system and stops the test
    • Runs seven installation tests automatically in one sequence with a single connection through Auto Test
    • Allows you to share test results in real time over your smartphone via Fluke Connect Measurements
    • 6 mA RDC-DD testing for EV charging stations
  • Features
    • Test the safety and functionality of AC electrical vehicle charging stations with the all-in-one solution
    • Pass/fail test results
    • Auto control pilot (CP) with waveform analysis
    • Compatible with TruTest™ Data Management Software
  • Features
    • Automatically Measure Power And Power Quality Parameters
    • Intuitive User Interface
    • High-Speed Voltage Transient Capture
    • Analysis And Reporting
    • Energy Loss Calculator
  • Features
    • Calibration of both temperature and pressure transmitters
    • Measure/source/simulate mA loop parameters
    • Measure and source mA, Volts DC, frequency, and resistance
    • Built-in 24 V loop power supply
    • Store and recall frequently used calibration set ups
  • Features
    • State-of-the-art readout accuracy of 0.01%
    • V, mA output, V, mA measurement, mA simulation, mA measurement/24V loop power supply
    • 2.8 inches TFT color screen, intuitive user interface, quick setting knob, easy to use
    • Built-in optional resistance of 2500 for HART communication
    • 1 uA current resolution, 1 mV voltage resolution
    • Source DC voltage to test input devices that can receive 0-SV, 1-SV or 0-1av signals
    • All measurement outputs adopt simple two-wire connection
    • Auto shutdown function to extend battery life (adjustable shutdown time up to 30 minutes)
    • Adjustable step and ramp time (seconds)
    • Adjustable span selection (0-20 mA or 4-20 mA)
    • Electronic valve test (use the step ramp key to simulate the defined mA value)
    • 4-20mA current clamp measurement function (optional)
    • HART communication function
  • Features
    • Pressure ranges to 60,000 psi (4,200bar)
    • 0.02%, 0.05%, 0.1% or 0.2% FS or 0.1% RD accuracy
    • % pressure indication with fan-shaped graph scale for visual reference
    • Fully temperature compensated accuracy
    • Panel mount gauges are available (optional)
    • Intrinsically safe version 681IS (optional)
    • Data logging (optional)
    • IP67 rated (681IS)
    • ISO 17025-accredited calibration w/data included
  • Features
    • Pressure range: up to 1,000 psi (70 bar)
    • Dual stage piston: Higher pressure with less effort
    • Multi-position versatility for on-site use
    • Lever pressurization: Efficient and quick stabilization
    • Portable: Weighs 3.5 lb (1.6 kg)
    • Low maintenance
  • Features
    • Pressure range: up to 10,000 psi (700 bar)
    • Dual stage piston: Higher pressure with less effort
    • Multi-position versatility for on-site use
    • Lever pressurization: Efficient and quick stabilization
    • Portable: Weighs 4.19 lb (1.9 kg)
    • High durability with low maintenance
  • Features
    • Portable, rugged, and quick to temperature
    • Metrology-level performance in stability, uniformity, accuracy and loading effect
    • Dual-zone control
    • Full HART field communicator
    • Process calibrator option provides a multi-channel readout for a reference thermometer, RTDs and TCs, task documentation, and HART Communication
    • Color touch screen display
    • Choose your own range option
    • Set point control by reference
    • Self-calibration feature
    • ISO 17025-accredited calibration w/data included
  • Features
    • Engineered for exceptional portability and performance
    • Extended temperature range: -30°C to 250°C
    • High-precision accuracy: ±0.1°C
    • Compatible with a wide range of probe types and sizes
    • Optional built-in multifunction process calibrator
    • Quick to temperature
    • Delivers outstanding stability and uniformity
    • Fast thermal response for efficient operation
    • Features advanced dual-zone heating technology
    • One touch self-calibration
    • Designed with robust electromagnetic interference protection
  • Feature
    • Quick and easy determination of Delta T in the thermal image using application-specific measurement functions DeltaHeat and DeltaCool
    • Ultra-sharp thermal images thanks to high infrared resolution (256 x 192 pixels)
    • Everything is simple with the Testo Smart App: easy to use and effortless documentation sent on site
    • Flexible to use with its wireless function or one-handed when directly attached to a smartphone
    • Highly practical and durable with IP54 protection and drop resistance up to 1.5 m
  • Feature
    • Very good image quality: IR resolution of 160 x 120 pixels, via integrated testo SuperResolution Technology 320 x 240 pixels
    • Very good measuring accuracy of ±2°C
    • Visualizing temperature differences from 0.1°C
    • Automatic detection of hot and cold spots
  • Feature
    • Very good image quality: IR resolution of 160 x 120 pixels, via integrated testo SuperResolution Technology 320 x 240 pixels
    • Very good measuring accuracy of ±2°C
    • Visualizing temperature differences from 0.1°C
    • Automatic detection of hot and cold spots
  • Feature
    • Very good image quality: IR resolution of 240 x 180 pixels, via integrated testo SuperResolution Technology 480 x 360 pixels
    • Wireless networking: wireless transmission of readings from the testo 770-3 clamp meter and the testo 605i thermohygrometer (both available separately)
    • Smart: the free testo Thermography App enables you to write and send reports on site, as well as saving them online, and lots more.
    • Large temperature measuring range from -30°C to +650°C
  • Feature
    • Highest image quality: IR resolution of 320 x 240 pixels, via integrated testo SuperResolution Technology 640 x 480 pixels
    • Precise measurement: thermal sensitivity of 0.05°C
    • Smart and wireless: use your mobile device with the free testo Thermography App and wirelessly transmit readings from the testo 770-3 clamp meter and the testo 605i humidity measuring instrument (both available separately)
    • Integrated laser marker – can also be precisely visualized as a measuring point in the thermal image
  • Feature
    • Best image quality: IR resolution of 320 x 240 pixels (with SuperResolution 640 x 480 pixels); NETD < 40 mk
    • Useful features: testo SiteRecognition intelligent image management and testo ScaleAssist automatic contrast adjustment
    • Extensive analysis and documentation: With the intuitive professional software testo IRSoft
    • Full control: Manual focus and interchangeable lenses
Go to Top