- Information display instrument
- 24-hour continuous operating mode
- Data transfer to the PC
- Audible and light threshold alarms
-
Features
- Numerical and graphical color display for up to 3 parameters
- IP65 metal housing
- Support for one Indigo compatible probe
- Tool-free locking wheel for the probe
- 24 V AC/DC power supply input
- 3 pre-configured analog outputs (mA or V)
- Service port on the front for connecting to Vaisala Insight PC software or Indigo80 handheld indicator
-
Features
- Generates stable humidity and temperature conditions (<+-0.1% RH, <+-0.01 Degree Celsius)
- Calibration solution for the laboratory and on-site
- Humidity equilibrium typically in only 5 minutes for HG2-S, 15 minutes for HG2-XL
- Calibrate multiple probes simultaneously
- << Auto >> Automated calibration optional
- << Remote API >>logging and control with third party software (optional)
- Integrated FDA 21 CFR part 11 compliant Rotronic HW4 software
-
Features
- Intrinsically safe (Exi) for operation in up to Zone 0 / 20
- Measures RH and T and outputs an extensive range of calculated parameters: for a full list, see Technical data (page 5).
- Designed for harsh conditions
- Temperature range between −70 … +180 °C (−94 … +356 °F) depending on the probe option
- Vaisala HUMICAP sensor features high accuracy, excellent long-term stability, and negligible hysteresis
- Display options: graphical LCD display and non-display model
- Traceable calibration (certificate included)
- Compatible with Vaisala Insight PC software
-
Features
-
Six models for demanding industrial applications
-
Full 0 ... 100 %RH measurement, wide temperature range -40...+180 °C (-40...+356 °F)
-
Pressure tolerance up to 100 bar
-
Excellent performance in harsh conditions; good chemical tolerance
-
Corrosion-resistant IP65/IP66 housing
-
5-point calibration (certificate included)
-
Two analog outputs, calibrated (certificate included)
-
RS232, ASCII output
-
-
Features
- Miniature probe head with low thermal mass for superior response time
- RH accuracy up to 0.8 %RH
- Temperature accuracy up to 0.1 °C (0.18 °F)
- Temperature measurement range −40 … +120 °C (−40 … +248 °F)
- Sensor purge provides superior chemical resistance
- Modbus RTU over RS-485
- Compatible with Indigo transmitters and Insight PC software
- Traceable calibration certificate: 6 points for humidity, 1 point for temperature
- M10×1.5 cable gland included for mounting the probe head
-
Features
- RH accuracy up to 0.8 %RH, Temperature accuracy up to 0.1 °C (0.18 °F)
- Temperature measurement range -70 ... +180 °C (-94 ... +356 °F)
- Vapor and pressure proof construction
- Probe and sensor warming functions minimize condensation on probe
- Sensor purge provides superior chemical resistance
- Plug & play compatible with Indigo series of transmitters
- Modbus RTU over RS-485
- Traceable calibration certificate: 6 points for humidity, 1 point for temperature
-
Features
- RH accuracy up to 0.8 %RH, Temperature accuracy up to 0.1 °C (0.18 °F)
- Temperature measurement range -70 ... +180 °C (-94 ... +356 °F)
- 250 mm (9.84 in) probe allows easy process installation through insulation
- Sensor purge provides superior chemical resistance
- Modbus RTU over RS-485
- Plug & play compatible with Indigo series of transmitters
- Traceable calibration certificate: 5 points for humidity, 1 point for temperature
- Sintered AISI316L filter standard in delivery
-
Features
- RH accuracy up to 0.8 %RH, Temperature accuracy up to 0.1 °C (0.18 °F)
- Temperature measurement range -70 ... +180 °C (-94 ... +356 °F)
- Operating pressure 0 ... 10 MPa (0 ... 100 bar)
- Sensor purge provides superior chemical resistance
- Modbus RTU over RS-485
- Plug & play compatible with Indigo series of transmitters
- Traceable calibration certificate: 5 points for humidity, 1 point for temperature
-
Features
- Compact size
- RH accuracy up to ±1.0 %RH
- Temperature accuracy up to ±0.2 °C (0.36 °F)
- Temperature measurement range −40 … +60 °C (−40 … +140 °F)
- Chemical purge provides superior chemical resistance
- Modbus RTU over RS-485
- Compatible with Indigo series transmitters and Insight PC software
- Traceable calibration certificate: 6 points for humidity, 1 point for temperature
-
Features
- Non-contact measurement.
- Suitable for flow inspection.
- Work with clamp-on sensors.
- Velocity range : 0 ... ±10 m/s
- Pipe size : DN15 ... DN6000 mm
- Liquid temperature : -30 ... 160°C
- Accuracy : ±1%
- Liquid type : Water, sea water, waste water, alcohol, beer, various kinds of oil etc which can conduct ultrasound single uniform liquid
-
Features
- Visual Range Up to 20 Meters
- High Accuracy
- Display temperature and humidity
- Reliable and stable sensors
- Calibration Function
- External Power and Wall Hanging
- Optional Accessories: Light, Sound, GSM Alarms
- PC Software ToMonitor + ToClient Software Management System
- 4 keys, could set deviation, Set upper and lower limits of the alarm
-
Features
- Stainless steel #304 interior and painted galvanized steel exterior for long life and beautiful appearance.
- Fitting the large number or volume testing.
- Power all linking control to provide the best safety.
- The internal volume may be randomly enlarged and contracted which design is depending on the environmental requirement of the user.
- And the move would be many fast when customer want to changer to another factory
- Adopt the Japanese Micro-Computer control system of English/ Chinese display with big size LCD (320*240 dots(. High function and simple to operate.
- Provide with RS-232 communication interface device, capable of linking with a computer to control, edit, record, and connect timer signal delay
-
Features
- Strong counter-rotating mixture of high and low temperatures.
- Features automatic positioning in both horizontal and vertical axes, plus pre warming, pre-cooling and recording of shock results.
- Uses the Garden DO2ts heating oil in hot and cold chambers to minimize the costs of oil changes.
- Large LCD (320 x 240 dots) with Chinese / English display of temperatures, with programmable mini-computer control system.
- This system is suitable for on-site use with choice of water cooling or air cooling.
-
Features
- 2-Zone/ 3-Zone Stationary Specimen, Exposure By Cooling Air/ Hot Air Changeover.
- The machine is divide into three sections: the high temperature chamber, the low temperature chamber and the testing chamber.
- The color touch panel control system was made in Japan can display Chinese / English. The big size liquid-crystal LCD (320X240) has been adopted.
- High formula memory capacity may be set to 100 patterns. the maximum cycle setting is 9999 cycles. The maximum setting of each section is 999Hrs 59Mins.
- Provided with RS-232C communication interface device, capable of controlling/ editing/ editing recording in line linkage with the computer and two set dynamic connection point (TIMER SIGNAL REPLAY) and convenient application.
-
Features
- This equipment features independent systems with vibration control and cross-temperature and cross-humidity controls. It can be set to test and display results for high temperatures, low temperatures, cross temperatures and humidity and vibration, either individually or at the same time.
- Moveable guide rails for easy testing separately or simultaneously.
- Large LCD display in Chinese or English plus 100-program memory and standard RS-232C computer interface.
-
Features
- The design mode of these sets is one body affords convenient application and less space occupation.
- It can separately test high temperature and constant temperature and humidity.
- All systems are individual and independent. The three sets type of the refrigstion system and three sets of the type heating and humidifying systems are adopted. The three set type systems afford stable control and high accuracy, prolonging the service life machine parts.
- All programmed instructions are microprocessor-controlled, with PID and automatic calculation to ensure precise and stable temperature and humidity control.
-
Features
- On desk design affords small volume with occupying space
- All programmed instructions are microprocessor-controlled. with PID and automatic calculation to ensure precise and stable temperature and humidity control.
- In the case of thermostat breakdown, a warning light switches on and temperature setting is changed to standard
- Heat is evenly distributed throughout the testing chamber to ensure a uniform testing temperature
-
Features
- System capacity: It could sign in 150 programs x 1500 partitions, partitions can be optionally divided and program can link up to each other.
- Loop configuration: 9999 x 999 looping time, can be divided into 5 independent sub-loops
- Output: Intelligent PID + SSR/ SCR two-way synchronous output, built-in advanced slope control logic
- Data: Touch panel dialogue box display, easy operation, built-in managemnet system of data content
- Curves drawing: When temperature, humidity and times are set up, the data can be immediately transferred into curves, actual operating curves can be attained during operations