Skip to content
-
Features
- Nominal pressure: 0 ... 10 mbar up to 0 ... 1000 mbar
- Accuracy: 0.35 % FSO
- Indication of measured values on a 4-digit LED display
- Rotatable and configurable display module
- 1, 2 or 4 independent PNP contacts, freely configurable
Optional Features
- IS-version: Ex ia = intrinsically safe for gases
- Customer specific versions
Areas of Application
- Mechanical and Plant Engineering
- HVAC
- Laboratory
-
Features
- Nominal pressure: 0 ... 600 bar up to 0 ... 2200 bar
- Accuracy: 0,35 % FSO
- Indication of measured values on a 4-digit LED display
- Rotatable and configurable display module
- 1, 2 or 4 independent PNP contacts, freely configurable
- Pressure sensor welded
- Extremely robust and excellent longterm stability
Optional Features
- Adjustability of span and offset (4 ... 20 mA / 3-wire)
- Customer specific versions
Areas of Application
- Mechanical and Plant Engineering
- Utility Vehicles / Mobile Hydraulics
-
Features
- Nominal pressure: 0 ... 6 bar up to 0 ... 600 bar
- Accuracy: 0.5 % FSO
- 1 analog output and up to 2 contacts
- Display and housing rotatable
- Perfect for oxygen applications
Areas of Application
- Mechanical and Plant Engineering
- Energy Industry
- Refrigeration Engineering
- Medical Technology
- Utility Vehicles / Mobile Hydraulics
-
Features
- Nominal pressure: 0 ... 2 bar up to 0 ... 400 bar
- Accuracy: 1.5 % FSO
- Display and housing rotatable
- Up to 2 contacts
- Configurable via display
Optional Features
Areas of Application
- Mechanical and Plant Engineering
- Energy Industry
-
Features
- Nominal pressure: 0 ... 6 mbar up to 0 ... 1000 mbar
- Accuracy: 0,35 % FSO
- Aluminum housing
- Rotatable and configurable display module
- 4-digit LED display
- Suited for non-aggressive gases and compressed air
Optional Features
- 1 / 2 PNP contacts
- customer specific versions
Areas of Application
- Mechanical and plant engineering
- HVAC
-
Features
- Nominal pressure: 0 ... 100 mbar up to 0 ... 600 bar
- Accuracy: 0,35 % FSO
- Analog output (optional): 4 ... 20 mA or 0 ... 10 V
- Indication of measured values on a 4-digit LED display
- Parametrization by IO-Link or set menu system (VDMA-conform)
- Rotatable and configurable display
- 2 contacts
Optional Features
- different mechanical connections
- customer specific versions
Areas of Application
- Mechanical and Plant Engineering
- Hydraulics
- Packaging and Paper Industry
-
Characteristics
- nominal pressure ranges from 0 ... 1 bar up to 0 ... 10 bar also -1 ... 0 bar
- 1 or 2 contacts
- Compact design
- Configurable via PC or programming device P6
Applications
- Pneumatic
- Vacuum technology
-
Features
- Nominal pressure: 0 ... 100 mbar up to 0 ... 600 bar
- Accuracy: 0.35 % (opt. 0.25 %) FSO
- Indication of measured values on a 4-digit LED display
- Rotatable and configurable display module
- 1 or 2 independent PNP contacts, freely configurable
Optional Features
- IS-version - Ex ia = intrinsically safe for gases and dust
- Pressure sensor welded
- Customer Specific Versions
Areas of Application
- Mechanical and plant engineering
- HVAC
- Environmental industry
-
Features
- Nominal pressure: 0 ... 100 mbar up to 0 ... 40 bar
- Accuracy: 0.35 % (opt. 0.25 %) FSO
- 1 or 2 independent PNP contacts, freely configurable
- Indication of measured values on a 4-digit LED display
- Rotatable and configurable display module
- Hygienic process connections with flush stainless steel diaphragm
- Configurable contacts (switch on / switch off points, hysteresis / window mode, switch on / switch off delay)
Optional Features
- IS-version - Ex ia = intrinsically safe for gases
- Analog Output - 2-wire: 4 ... 20 mA, 3-wire: 4 ... 20 mA with Turn Down 1:5, 0 ... 10
- Customer Specific Versions
Areas of Application
- Medical Technology
- Food and Beverage
-
Features
- nominal pressure: 0 ... 400 mbar up to 0 ... 600 bar
- accuracy: 0.5 % FSO
- rotatable and configurable display module
- indication of measured values on a 4-digit LED display
- 1 or 2 independent PNP contacts, freely configurable
Optional Features
- IS-version
Ex ia = itrinsically safe for gases
- pressure port PVDF
- customer specific versions
Areas of Application
- Mechanical and plant engineering mechanical and plant engineering
- Environmental industry environmental industry
-
Features
- Nominal pressure: 0 ... 2 bar up to 0 ... 400 bar
- Accuracy: 1 % FSO
- 1 or 2 contacts
- Configurable via PC or programming device P6
- Diaphragm ceramic (96 %)
Optional Features
- Oil- and grease free application
Areas of Application
- Mechanical and plant engineering
- Energy Industry
-
Features
- App integration via Bluetooth for fast and convenient monitoring and reporting on site
- Refrigerant update in the instrument via App
- Calculation of superheating/subcooling in real time with up to two external temperature probes
- 2-way valve block with three connections, three hose parkers and sight glass
- 250 hours‘ battery life
-
Characteristics
- Ceramic Sensor
- Nominal pressure ranges from 0 ... 160 mbar up to 0... 20 bar
- Accuracy according to IEC 60770: 0.1 % FSO
- Preferred areas of use for Flush, Hygienical Application
-
Characteristics
- Stainless Steel Sensor
- Nominal pressure ranges from 0 ... 400 mbar up to 0 ... 40 bar
- Accuracy according to IEC 60770: 0.1 % FSO
- Preferred areas of use for Flush, Hygienical Application
-
Characteristics
- Ceramic Sensor
- Nominal pressure ranges from 0 ... 160 mbar up to 0... 20 bar
- Accuracy according to IEC 60770: 0.1 % FSO
- Preferred areas of use for Process, Oil And Gas Industry
-
Characteristics
- Stainless Steel Sensor
- Nominal pressure ranges from 1 mbar up to 20 bar
- Accuracy according to IEC 60770: 0.075 % FSO
- Preferred areas of use are Process, Oil And Gas Industry
Page load link