Features
- Digital sensor applied for MEMS technology
- Embedded RS485 communication port based on MODBUS RTU/ASCII
- Excellent long term stability and self-digital correction
- Quick counter reaction speed (within 4 second)
- Slim size - 310(L) x 280(H) x 45(D) mm
-
Features
- Humidification (heating)
- Dehumidification (cooling) output
- High/Low alarm output
- Min. on/off maintaining time setup
- Selection on/off output when sensor error occurs
- Sensor correction
- Sensor error detection
- Relay output manual control
- Transmission output
- RS485 communication (MODBUS)
-
Main Function
- Humidification/dehumidification output
- High/Low alarm output
- Min. on/off maintaining time setup
- Selection on/off output when sensor error occurs
- Sensor correction
- Sensor error detection
- Selection of displaying decimal point
-
Main Function
- Output controllable based on measured pressure value (increase and decrease)
- Alternative operation available between freezing exclusive model and booster
- Pump unit control model
- RS485 MODBUS
-
Main Function
- 3 stage fan speed controllable
- 4 kind (stop / high / middle / low) airflow choosable
- Unification of temperature control function
- Data backup
- Self diagnostic
- RS485 communication (MODBUS)
-
Main Function
- Embedded run/stop switch, motor on/off, load run, auto-stop, manual stop, operation delay, load delay, embedded timer
- Pressure / temperature high level
- Temperature low level (standby for starting)
- Interlock input signal (emergency switch, OCR reverse phase)
- Usable thermometer and manometer
- RS485 communication (MODBUS)
-
Main Function
- Embedded run/stop switch, motor on/off, load run, auto-stop, manual stop, operation delay, load delay, embedded timer
- Pressure / temperature high level
- Temperature low level (standby for starting)
- Interlock input signal (emergency switch, OCR reverse phase)
- Usable thermometer and manometer
- RS485 communication (MODBUS)
-
Main Function
- Defrosting (auto / manual)
- Defrosting stop delay
- 2 air inlet/outlet sensors
- One sensor for defrost recovery
- High / Low alarm output
- Indicator (FixView) connection
- RS485 communication (MODBUS)
-
Main Function
- Defrosting (auto / manual)
- Defrosting stop delay
- Evaporation fan control
- Air inlet/outlet sensor: 2EA
- Defrost recovery sensor: 1EA
- Virtual temperature sensor computing
- Door open alarm
- Emergency call
- Night operation
- High (low) temperature alarm output
- RS485 communication (MODBUS)
-
Main Function
- Uniform step control
- Operation with intelligent shift high / low alarm output
- Sensor correction / Sensor error detection
- Transmission output
- RS485 communication (MODBUS)
-
Main Function
- Efficient defrosting in geothermy heat pump system
- Defrosting execution by measuring of ambient humidity and temperature
-
Main Function
- Defrosting (auto / manual)
- Fan control
- Efficient delay
- Room temperature sensor: 1EA
- Defrost sensor: 1EA
- High (low) temperature alarm output
- Room temperature transmission output (4~20 mA)
- RS485 communication (MODBUS)
-
Main Function
- PID degree of superheat control through defense and safety compensation
- Degree of superheat control for various refrigerant
- PMW (opening ratios control)
- Remote operation
- Transmission output
- RS485 communication (MODBUS)
-
Main Function
- Total control and detection (protection) for freezers
- Function of start, restart, pump down, alarm delay timer
- Discharge gas detection (high & low temperature)
- Individual alarm message (OC, HP, LP, OP, INT)
- RS485 communication (MODBUS)
-
Main Function
- Heating / cooling output
- Independent timer output
- High / Low alarm output
- Precise temperature control
- Sensor correction
- Sensor error detection
- Data back up
- Minimum on/off maintaining time setup
- RS485 communication (MODBUS)
- Transmission output
-
Main Function
- Heating/cooling output
- High / Low alarm output
- Precise temperature control.
- Sensor correction, sensor error detection
- Sensor error detection
- Data backup
- Min. on/off maintaining time setup
- Transmission output
- RS485 communication (MODBUS)
-
Main Function
- Heating / cooling output
- Precise temperature control
- Sensor correction
- Sensor error detection
- Data back up
- Minimum on/off maintaining time setup
- Auto-output operation cycle settable in case of sensor error
-
Main Function
- Heating / cooling output
- High / Low alarm output
- Precise temperature control
- Sensor correction
- Sensor error detection
- Data back up
- Minimum on/off maintaining time setup
- RS485 communication (MODBUS)
- Transmission output
-
Main Function
- Heating / cooling output
- Independent timer output
- High / Low alarm output
- Defrost output
- Precise temperature control
- Sensor correction
- Sensor error detection
- Data back up
- Minimum on/off maintaining time setup
- RS485 communication (MODBUS)
- Transmission output
- Auto-output operation cycle settable in case of sensor error
-
Main Function
- Heating / cooling output
- Independent timer output
- High / Low alarm output
- Defrost output
- Precise temperature control
- Sensor correction
- Sensor error detection
- Data back up
- Minimum on/off maintaining time setup
- RS485 communication (MODBUS)
- Transmission output
- Auto-output operation cycle settable in case of sensor error