Skip to content
Features
Stainless Steel Sensor
Nominal pressure: 0 ... 1 mH2O up to 0 ... 100 mH2O
Accuracy: 0.35 % (opt. 0.25 %) FSO
Diameter 35 mm
Cable and sensor section detachable
Excellent linearity
Small thermal effect
Integrated lightning protection and increased over voltage protection; 8 kA gas discharge tube (8/20 μsec); 4 kV surge l-l/l-e according to EN61000-4-5
Optional Features
SIL 2 (safety integrity level) according to IEC 61508 / 61511
different kinds of cable and elastomeres
customer specific versions e.g. special pressure ranges
Areas of Application
Energy Industry
Environmental Industry
Features
Stainless Steel Sensor
Nominal pressure: 0 ... 400 mbar up to 0 ... 40 bar
Accuracy: 0.1 % FSO
Thermal error in compensated range -20 … 80 °C: 0.2 % FSO TC 0.02 % FSO / 10 K
Turn-down 1:10
Communication interface for adjusting of offset, span and damping
Optional Features
IS-version (Ex ia = intrinsically safe for gases and dusts)
Adjustment of nominal pressure gauges (factory-provided)
Areas of Application
Chemical Industry
Environmental Industry
Features
Stainless Steel Sensor
Nominal pressure: 0 ...4 mH2O up to 0...200 mH2O
Accuracy: 0.1 % FSO
Diameter 35 mm
Cable and sensor section detachable
Thermal error in compensated range -20...70°C: 0.2 FSO TC 0.02% FSO/10K 0,02 % FSO / 10K
High Accuracy
Communication connection
turn-down 1:10
Optional Features
IS-version (Ex ia = intrinsically safe for gases and dusts)
SIL 2 application according to IEC 61508 / IEC 61511
Different electrical connections
Customer specific versions e.g. special pressure range
Areas of Application
Mechanical and Plant Engineering
Energy Industry
Environmental Industry
Features
Stainless Steel Sensor
Nominal pressure range from 0 ... 4 mH2O up to 0 ... 200 mH2O
Accuracy: 0.1 % FSO
Diameter 35 mm
Cable and sensor section detachable
Thermal error in compensated range -20...70°C: 0.2 FSO TC 0.02% FSO/10K 0,02 % FSO / 10K
High accuracy
Communication connection
Turn-down 1:10
Optional Features
IS-version (Ex ia = intrinsically safe for gas and dust)
Mounting accessories as cable gland and terminal clamp in stainless steel
Different kinds of cables
Different kinds of seal materials
Areas of Application
Energy Industry
Environmental Industry
Features
Stainless Steel Sensor
Nominal pressure range from 0 ... 1 mH2O up to 0 ... 250 mH2O
Accuracy: 0.35 % (opt. 0.25% / 0.1 %) FSO
Diameter 35 mm
Cable and sensor section detachable
Excellent long term stability
High accuracy
Optional Features
IS-version (Ex ia = intrinsically safe for gas and dust)
SIL 2 (Safety integrity level)
Customer specific versions
Mounting accessories as cable gland and terminal clamp of stainless steel
Different kinds of cables
Different kinds of seal materials
Areas of Application
Energy Industry
Environmental Industry
Features
Nominal pressure: 0 ... 1 mH2O up to 0 ... 250 mH2O
Nominal temperature from 0 ... 30 °C up to 0 ... 70 °C
Accuracy: 0.35 % (opt. 0.25 %) FSO
Diameter 26.5 mm
Separate output signals for pressure and temperature ranges
Easy handling
low maintenance and wiring costs
Optional Features
Drinking water certificate acc. to DVGW and KTW
Different kinds of cables
Different kinds of elastomers
Customer specific versions
Areas of Application
Energy Industry
Environmental Industry
Features
Nominal pressure: 0 ... 4 mH2O up to 0 ... 200 mH2O
Accuracy: 0,1 % FSO
Diameter 26,5 mm
Small thermal effect
Excellent accuracy
Excellent long term stability
Optional Features
IS-version (Ex ia = intrinsically safe for gas and dust)
Drinking water certificate according to DVGW and KTW
Different kinds of cables
Different kinds of seal materials
Areas of Application
Energy Industry
Oil and Gas Industry
Environmental Industry
Features
Stainless Steel Sensor, Stainless Steel Probe
Nominal pressure: 0 ... 1 mH2O up to 0 ... 250 mH2
Accuracy: 0.35 % (opt. 0.25% / 0.1 %) FSO
Diameter 26.5 mm
Small thermal effect
Excellent long term stability
High Accuracy
Features
Stainless Steel Sensor
Nominal pressure: 0 ... 1 mH2O up to 0 ... 250 mH2O
Accuracy: 0.35 % (opt. 0.25 %) FSO
Diameter 19 mm for cramped areas e.g. 1" observation well
Small thermal effect
Excellent linearity
Excellent long term stability
Optional Features
Different kinds of cable
Customer specific versions e.g. special pressure ranges
Areas of Applications
Energy Industry
Environmental Industry
Features
Ceramic Sensor
Nominal pressure: 0 ... 40 cmH2O up to 0 ... 100 mH2O
Accuracy: 0.35 % (opt. 0.25 %) FSO
Diameter 45 mm
Cable and sensor section detachable
Chemical resistance
Housing PP-HT
Integrated lightning protection and increased overvoltage protection; 8 kA gas discharge tube (8/20 μsec); 4 kV surge l-l/l-e according to EN61000-4-5
Optional Features
Cable protection (on request)
Diaphragm pure ceramic (99,9 % AI2O3)
Different kinds of cables
Different kinds of elastomeres
Areas of Application
Chemical Industry
Environmental Industry
Features
High Purity Ceramic Sensor
Nominal pressure: 0 ... 40 cmH2O up to 0 ... 100 mH2O
Accuracy: 0.35 % (opt. 0.25 %) FSO
Diameter 45 mm
Chemical resistance
High over pressure capability
Pure ceramic sensor
Especially for tank level measurement of viscous and aggressive media
Housing material PP-HT or PVDF
Diaphragm ceramics Al2O3 (99.9 %)
Optional Features
Different kinds of cable and seal materials
Prepared for mounting with pipe
Areas of Application
Chemical Industry
Environmental Industry
Features
Ceramic Sensor
Nominal pressure: 0 ... 1 mH2O up to 0 ... 100 mH2O
Accuracy: 0.35 % (opt. 0.25 %) FSO
Diameter 35mm
Diaphragm ceramics Al2O3 (99.9 %)
Cable and sensor section detachable
Excellent long term stability
Integrated lightning protection 8 kA gas discharge tube (8/20µsec); 4 kV surge l-l/l-e according to EN61000-4-5
Optional Features
Mounting accessories
Different kinds of elastomer
Customer specific versions e. g. special pressure ranges
Areas of Application
Chemical Industry
Environmental Industry
Features
Nominal pressure: 0 ... 4 mH2O up to 0 ... 100 mH2O
Accuracy: 0.5 % FSO
Diameter 35 mm
Excellent long term stability
Easy handling
Optional Features
SIL 2 (safety integrity level) according to IEC 61508 / IEC 61511
Different kinds of cables and elastomeres
Customer specific version e.g. special pressure ranges
Areas of Application
Chemical Industry
Environmental Industry
Features
Ceramic Sensor, Flush, Plastic Probe
Nominal pressure: from 0 ... 6 mH2O up to 0 ... 200 mH2O
Diameter 21 mm
Excellent linearity
Excellent long term stability
Accuracy: 0,5% FSO
Suitable for hydrostatic level measurement e.g. 3/4" pipes
Optional Features
Different cable materials
Customer specific versions, e.g. special pressure rang
Areas of Applications
Chemical Industry
Environmental Industry
Ceramic Sensor, Probe
Nominal pressure range from 0 ... 1 mH2O up to 0 ... 100 mH2O
Accuracy according to IEC 60770: 0.25 % FSO
Features
Nominal pressure: 0 ... 60 cmH2O up to 0 ... 200 mH2O
Accuracy: 0.1 % FSO
Shipping approvals: American Bureau of Shipping (ABS), Bureau Veritas (BV), China Classification Society (CCS), Det Norske Veritas (DNV), Germanischer Lloyd (GL), Lloyd's Register (LR)
Diameter 39.5 mm
HART®-communication (setting of offset,span and damping)
High overpressure capability
High long term stability
Optional Features
IS-version; Ex ia = intrinsically safe for gases and dusts
Diaphragm 99,9 % AI2O3
Different housing materials (stainless steel, CuNiFe)
Screw-in and flange version
Accessories e.g. assembling and probe flange, mounting clamp
Areas of Application
Marine Industry
Shipbuilding/ Offshore Industry
Features
Nominal pressure: from 0 ... 40 cmH2O up to 0 ... 200 mH2O
Diameter 39.5 mm
LR-certificate (Lloyd´s Register)
DNV ▪ GL Approval (Det Norske Veritas ▪ Germanischer Lloyd)
ABS-certificate (American Bureau of Shipping)
CCS-certificate (China Classification Society)
High overpressure resistanc
High long-term stability
Optional Features
Diaphragm Al2O3 99.9 %
Different housing materials (stainless steel, CuNiFe)
IS-version, Ex ia = intrinsically safe for gas
Screw-in and flange version
Accessories e.g. assembling and probe flange, mounting clamp
Areas of Application
Water Industry
Shipbuilding/ Offshore Industry
Features
Nominal pressure: from 0 ... 4 mH2O up to 0 ... 100 mH2O
Acuracy: 0,35 % FSO
Diameter 22 mm
Excellent long term stability
Highly appropriated for wastewater, sludge and viscous media
Optional Features
Diaphragm ceramics 99,9% Al2O3 (on request)
IS-version (in preparation), Ex ia = intrinsically safe for gases and dust
Mounting with stainless steel tube
Different kinds of cable
Different kinds of elastomer
Areas of Application
Chemical Industry
Energy Industry
Environmental Industry
Features
Nominal pressure range 0 ... 60 cmH2O up to 0 ... 100 mH2O
Accuracy: 0.1 %
Diameter 39.5 mm
HART®-communication (setting of offset. span and damping)
Permissible temperatures up to 85 °C
High long term stability
Optional Features
IS-version (Ex ia = intrinsically safe for gas and dust)
Mounting with stainless steel pipe
Flange version
Diaphragm 99.9 % AI2O3
Accessories e.g. transmitter and mounting flanges and terminal clamp
Areas of Application
Water Industry
Sewage Industry
fuel and Oil Industry
Features
Nominal pressure: 0 ... 40 cmH2O up to 0 ... 100 mH2O
Accuracy: 0,25 % / 0.35 % FSO
Diameter 39.5 mm
Especially for sewage, viscous and pasty media
Areas of Application
Chemical Industry
Energy Industry
Environmental Industry
Features
Nominal pressure range 0 ... 60 cmH2O up to 0 ... 100 mH2O
Accuracy: 0.1 %
Diameter 39,5 mm
Cable and sensor section detachable
HART®-communication (setting of offset. span and damping)
Permissible temperatures up to 85 °C
High long term stability
Optional Features
IS-version (Ex ia = intrinsically safe for gas and dust)
Cable protection via corrugated pipe
Diaphragm (AI2O3 99,9 %)
Accessories e.g. mounting flange with cable gland and terminal clamp
Areas of Application
Chemical Industry
Energy Industry
Environmental Industry
Features
Nominal pressure: 0 ... 40 cmH2O up to 0 ... 100 mH2O
Accuracy: 0.35 % (opt. 0.25 %) FSO
Diameter 39.5 mm
Cable and sensor section detachable
Ceramic Sensor
Especially for sewage, viscous and pasty media
Optional Features
IS-protection (Ex ia = intrinsically safe for gas and dust)
Cable protection via corrugated pipe
Diaphragm pure ceramic (99,9 % AI2O3)
Different kinds of cable
Different kinds of elastomeres
Areas of Application
Chemical Industry
Energy Industry
Environmental Industry
Features
Nominal pressure: 0 ... 40 mbar up to 0 ... 20 bar
Accuracy: 0.35 % (opt. 0.25 %) FSO
Pressure port G 1 1/2" for pasty and polluted media
Ceramic Sensor
Optional Features
IS-version (Ex ia = intrinsically for gases and dusts)
Pressure port PVDF for aggressive media
Diaphragm pure ceramic (99,9 % Al2O3)
Customer specific versions
Areas of Application
Mechanical and plant engineering
Laboratory
Environmental Industry
Features
Nominal pressure: 0 ... 400 mbar up to 0 ... 60 bar
Accuracy: 0.5 % FSO
Pressure port G 3/4" flush
Ceramic Sensor, Plant And Mechanical Engineering
Optional Features
IS-version (only for 4... 20 mA / 2-wire): Ex ia = intrinsically safe for gases and dusts
SIL 2 application according to IEC 61508 / IEC 61511
Pressure port PVDF for aggressive media
Different electrical and mechanical connections
Customer specific versions
Areas of Application
Mechanical and Plant Engineering
Energy Industry
Medical Technology
Environmental Industry
Features
Nominal pressure: from 0 ... 4 mH2O up to 0 ... 250 mH2O
Nominal temperature from 0 ... 30 °C up to 0 ... 70 °C
Accuracy: 0,5 % FSO
Diameter 26,5 mm
Separate output signals for pressure and temperature ranges
Excellent accuracy
Easy handling
Low maintenance and wiring costs
Optional Features
Different kinds of cables
Different kinds of seal materials
Customer specific versions
Areas of Application
Energy Industry
Environmental Industry
Features
Ceramic Sensor, Stainless Steel Probe, Ø27mm,
Nominal pressure range from 0 ... 4 mH2O up to 0 ... 250 mH2O
Accuracy according to IEC 60770: 0.5 % FSO
Features
Ceramic Sensor, Ø17mm
Different cable material
Customer specific versions e.g. special pressure ranges
Nominal pressure range from 0 ... 6 mH2O up to 0 ... 200 mH2O
Areas of Application
Energy Industry
Environmental Industry
Page load link