Skip to content
Features
Single-use temperature monitor ideal for vaccine transport and storage
Monitors and records up to 85 days of data
Large, easy to ready LCD display
No software required to download data
Built-in USB connector, no special reading devices needed
Automatically creates secure PDF report and CSV file
Trip history statistics available on LCD
Patented Shadow Log feature guarantees data even if the shipper fails to start the logger
Recorded data automatically scales to graph
Features
Single channel, external Cryo probe
Automatically generates PDF report and CSV file
Large easy-to-read LCD
Multi-language FlashLink Program Manager software
Summary analysis of data, with alarm information
Audible and/or visual alarms
Degree Minutes and MKT calculations
Low battery indicator on LCD
Features
Monitor ultra low temperature during storage and transport using dry ice or liquid nitrogen
External sensor tracks temperature of products
No need to open shipping box or vehicle door to read data
Location data plotted on Google Maps
Data is automatically uploaded to 24/7 cloud service
On-board memory records data every 10 minutes
Option to download PDF report to PC with USB cable
Optional Bluetooth printer provides paper chart on demand
Features
Monitor vaccines in ultra-low temperatures
Ideal for storage and transport with dry ice
Compatible with CDC guidelines
21 CFR Part 11 compliant software
Single channel, external sensor
Automatically generates PDF, CSV and Daily Log reports
Audible and/or visual alarms
Low battery indicator on LCD
Quick disconnect cable to download logger
Scroll through recorded data on LCD
Features
Compact single-use electronic indicator
Monitor vaccines during storage and transport
Refrigerated vaccine alarms: low 2°C / high 8°C
Frozen vaccine alarms: low -25°C / high -15°C
Immediate visual pass/fail indicator
Mounted on high-visibility locator card
Post-trip evaluation service available
Features
WHO Prequalified E006 Temperature Monitoring Device
Compatible with CDC guidelines
Ideal for monitoring vaccines and liquid medicines during storage
21 CFR Part 11 compliant software
Single channel, external sensor in glycol bottle
Glycol buffered sensor emulates products and prevents false alarms
Automatically generates PDF, CSV and Daily Log reports
Audible and/or visual alarms
Low battery indicator on LCD
Quick disconnect cable to download logger
Easy reset to start a new logging period without using FlashLink software
User programmable: manual or auto start, logging intervals, hi/low alarms
Scroll through statistics on LCD
Features
Display of indoor-outdoor temperatures
Outdoor temperature via cable
Also for the monitoring of freezer / aquarium
Max.-min. values
Extra-large display
Features
Two channel logging capability
Includes one sensor with blunt tip probe
Optional second sensor: 20963 (blunt tip) or 20964 (glycol bottle)
Data transmitted through cellular connections or Wi-Fi
Cloud-based application for system administration, data collection and analysis
Features
Single-use, irreversible temperature indicator
Monitor refrigerated environments during shipping, storage, handling
Immediate visual confirmation of exposure to temperature excursions
Easy interpretation of results by receiver or end user
Assists with shelf life, quality, and efficacy decisions
Identify cold chain problems
Features
Measurement range -100 to +100°C (-148 to +212°F)
T-type probe on 1m cable
Stores over 32,000 readings
Logging rates between 1 second and 12 hours
Immediate and delayed logging start
User-programmable alarm thresholds
Status indication via red and green LEDs
EasyLog software available as a free download
Features
Measurement range -100 to +100°C (-148 to +212°F)
T-Type probe on 1m cable
Stores over 32,000 readings
High contrast LCD, with four digit temperature display function
Logging rates between 1 second and 12 hours
Immediate, delayed and push-to-start logging
User-programmable alarm thresholds
Status indication via red and green LEDs
EasyLog software available as a free download
Features
Measurement range -100 to +100°C (-148 to +212°F)
T-Type probe on 1m cable
Stores over 32,000 readings
High contrast LCD, with four digit temperature display function
Logging rates between 1 second and 12 hours
Immediate, delayed and push-to-start logging
User-programmable alarm thresholds
Status indication via red and green LEDs
EasyLog software available as a free download
Features
Measurement range -100 to +100°C (-148 to +212°F)
High accuracy T-Type probe on 2m cable
Stores over 32,000 readings
High contrast LCD, with four digit temperature display function
Logging rates between 1 second and 12 hours
Immediate, delayed and push-to-start logging
User-programmable alarm thresholds
Status indication via red and green LEDs
EasyLog software available as a free download
Features
-40 to +125°C (-40 to +257°F) measurement range
Stores over 32,000 readings
EasyLog software available as a free download
Logging rates between 1 second and 12 hours
High contrast LCD, with four digit temperature display function
Immediate, delayed and push-to-start logging
User-programmable alarm thresholds
Status indication via red and green LEDs
Supplied with a thermistor glycol probe
Features
Measurement range -100 to +100°C (-148 to +212°F)
T-type probe on 1m cable
Wirelessly stream and view data on the EasyLog Cloud, App or on a PC
View and analyse multiple sensors, including graphing of historic data
Configurable high and low alarms with indicator
Easy sensor set-up using free PC software or App
Features
-Measurement range -100 to +100°C (-148 to +212°F)
High accuracy T-type probe on 2m cable
Wirelessly stream and view data on the EasyLog Cloud, App or on a PC
View and analyse multiple sensors, including graphing of historic data
Configurable high and low alarms with indicator
Easy sensor set-up using free PC software or App
Features
WiFi datalogger with external thermistor probe in a glycol bottle to mimic a vaccine
Temperature measurement range -40 to +60°C (-40 to +140°F)
Wirelessly stream and view temperature data on the EasyLog Cloud, App or on a PC
Easy sensor set-up using free PC software application
Configurable high and low alarms with indicator
Sensor memory stores all data even if WiFi is temporarily disconnected
Calibration certificate supplied at 2 and 8°C
Features
Dual channel WiFi datalogger with two external thermistor probes in glycol bottles to mimic vaccines
Temperature measurement range -40 to +60°C (-40 to +140°F)
Wirelessly stream and view temperature data on the EasyLog Cloud, App or on a PC
Easy sensor set-up using free PC software application
Configurable high and low alarms with indicator
Sensor memory stores all data even if WiFi is temporarily disconnected
Calibration certificate supplied at 2 and 8°C
Features
Temperature measurement range -40 to +60 °C (-40 to +140 °F)]
Configurable alarm levels with on-board warning light and sounder
Digital calibratable probe with 3m cable
No need to remove from service for recalibration, just replace the probe
Wirelessly stream and view data on the EasyLog Cloud, and configure alarm email notifications
View and analyze multiple devices, including graphing of historic data
Easy device setup using free PC software or mobile app
Device memory stores all data even if Wi-Fi is temporarily disconnected
Traceable calibration certificate supplied at 2°C and 8°C
Features
Measurement range -100 to +100°C (-148 to +212°F)
T-type probe on 1m cable
Dual channel recording through two external thermocouple probes
Wirelessly stream and view data on the EasyLog Cloud, App or on a PC
View and analyze multiple sensors, including graphing of historic data
Configurable high and low alarms with indicator
Easy sensor set-up using free PC software or App
Features
Measurement range -100 to +100°C (-148 to +212°F)
High accuracy T-type probe on 2m cable
Dual channel recording through two external thermocouple probes
Wirelessly stream and view data on the EasyLog Cloud, App or on a PC
View and analyze multiple sensors, including graphing of historic data
Configurable high and low alarms with indicator
Easy sensor set-up using free PC software or App
Features
Can be installed as part of a 21CFR compliant system with additional controls including permission-based use, authority level sign-off and full system audit
Measurement range -100 to +100°C (-148 to +212°F)
T-type probe on 1m cable
Wirelessly stream and view data on the EasyLog 21CFR Cloud
Configurable high and low alarms with indicator
Easy sensor set-up using free 21CFR WiFi Sensor Software
Features
Can be installed as part of a 21CFR compliant system with additional controls including permission-based use, authority level sign-off and full system audit
Measurement range -100 to +100°C (-148 to +212°F)
T-type probe on 1m cable
Wirelessly stream and view data on the EasyLog 21CFR Cloud
Configurable high and low alarms with indicator
Easy sensor set-up using free 21CFR WiFi Sensor Software
Features
Can be installed as part of a 21CFR compliant system with additional controls including permission-based use, authority level sign-off and full system audit
Measurement range -100 to +100°C (-148 to +212°F)
T-type probe on 1m cable
Wirelessly stream and view data on the EasyLog 21CFR Cloud
Configurable high and low alarms with indicator
Easy sensor set-up using free 21CFR WiFi Sensor Software
Features
Measurement range -100 to +100°C (-148 to +212°F)
High accuracy T-type probe on 2m cable
Dual channel recording through two external thermocouple probes
Wirelessly stream and view data on the EasyLog Cloud, App or on a PC
View and analyze multiple sensors, including graphing of historic data
Configurable high and low alarms with indicator
Easy sensor set-up using free PC software or App
Features
Can be installed as part of a 21CFR compliant system with additional controls including permission-based use, authority level sign-off and full system audit
-40°C to +60°C (-40°F to +140°F) temperature measurement range
Wirelessly stream and view data on the 21CFR Cloud
Configurable high and low alarms with indicator
Easy sensor set-up using free PC software application
Calibration certificate supplied at 2 and 8°C
Features
Can be installed as part of a 21CFR compliant system with additional controls including permission-based use, authority level sign-off and full system audit
-40°C to +60°C (-40°F to +140°F) temperature measurement range
Wirelessly stream and view data on the 21CFR Cloud
Configurable high and low alarms with indicator
Easy sensor set-up using free PC software application
Calibration certificate supplied at 2 and 8°C
Features
Measurement range -100 to +100°C (-148 to +212°F)
T-type probe on 1m cable
Records and uploads temperature data to the EasyLog Cloud
Access live temperature data via any Internet Browser or the EasyLog Cloud App
Set up alarm options for temperature zone breaches – email alerts, beeper alarms or LED flash alerts
Battery life of up to 2 years
Features
Measurement range -100 to +100°C (-148 to +212°F)
High accuracy T-type probe on 2m cable
Records and uploads temperature data to the EasyLog Cloud
Access live temperature data via any Internet Browser or the EasyLog Cloud App
Set up alarm options for temperature zone breaches – email alerts, beeper alarms or LED flash alerts
Battery life of up to 2 years
Features
Measurement range -100 to +100°C (-148 to +212°F)
T-type probe on 1m cable
Records and uploads temperature data to the EasyLog Cloud
Access live temperature data via any Internet Browser or the EasyLog Cloud App
Set up alarm options for temperature zone breaches – email alerts, beeper alarms or LED flash alerts
Battery life of up to 2 years
Features
Measurement range -100 to +100°C (-148 to +212°F)
High accuracy T-type probe on 2m cable
Records and uploads temperature data to the EasyLog Cloud
Access live temperature data via any Internet Browser or the EasyLog Cloud App
Set up alarm options for temperature zone breaches – email alerts, beeper alarms or LED flash alerts
Battery life of up to 2 years
Features
Measurement range -100 to +100°C (-148 to +212°F)
T-type probe on 1m cable
Stores over 32,000 readings
Logging rates between 1 second and 12 hours
Immediate and delayed logging start
User-programmable alarm thresholds
Status indication via red and green LEDs
Use as part of a 21CFR Part 11 compliant system
EasyLog 21CFR software available as a free download
Features
Measurement range -100 to +100°C (-148 to +212°F)
High accuracy T-type probe on 2m cable
Stores over 32,000 readings
Logging rates between 1 second and 12 hours
Immediate and delayed logging start
User-programmable alarm thresholds
Status indication via red and green LEDs
Use as part of a 21CFR Part 11 compliant system
EasyLog 21CFR software available as a free download
Features
-40 to +125°C (-40 to +257°F) measurement range
Stores over 32,000 readings
EasyLog software available as a free download
Logging rates between 1 second and 12 hours
High contrast LCD, with four digit temperature display function
Immediate, delayed and push-to-start logging
User-programmable alarm thresholds
Status indication via red and green LEDs
Supplied with a thermistor glycol probe
Features
-40 to +125°C (-40 to +257°F) measurement range
Stores over 250,000 readings
Logging rates between 2 seconds and 1 hour
On screen menu and graphing to start, stop, review and restart the logger in the field
Triggered logging mode to start recording data once a user defined level is met
High contrast, greyscale, backlit, graphic LCD screen to denote status and alarm levels
User-programmable audible alarm thresholds with highly visible confidence/alarm LEDs
EasyLog software available as a free download
Features
High and low temperature alarm level notifications
Daily, weekly or monthly summary SMS messages
Setup using the free EasyLog SMS Apps available from Google Play and the App Store
-40 to 60°C (-40 to 140°F) measurement range using supplied probe
Glycol bottle probe mimics vaccine in storage for accurate temperature monitoring.
Powered by four Alkaline AA batteries
Page load link