- RH accuracy up to 0.8 %RH, Temperature accuracy up to 0.1 °C (0.18 °F)
- Temperature measurement range -70 ... +180 °C (-94 ... +356 °F)
- 250 mm (9.84 in) probe allows easy process installation through insulation
- Sensor purge provides superior chemical resistance
- Modbus RTU over RS-485
- Plug & play compatible with Indigo series of transmitters
- Traceable calibration certificate: 5 points for humidity, 1 point for temperature
- Sintered AISI316L filter standard in delivery
-
Features
-
Features
- RH accuracy up to 0.8 %RH, Temperature accuracy up to 0.1 °C (0.18 °F)
- Temperature measurement range -70 ... +180 °C (-94 ... +356 °F)
- Vapor and pressure proof construction
- Probe and sensor warming functions minimize condensation on probe
- Sensor purge provides superior chemical resistance
- Plug & play compatible with Indigo series of transmitters
- Modbus RTU over RS-485
- Traceable calibration certificate: 6 points for humidity, 1 point for temperature
-
Features
- Miniature probe head with low thermal mass for superior response time
- RH accuracy up to 0.8 %RH
- Temperature accuracy up to 0.1 °C (0.18 °F)
- Temperature measurement range −40 … +120 °C (−40 … +248 °F)
- Sensor purge provides superior chemical resistance
- Modbus RTU over RS-485
- Compatible with Indigo transmitters and Insight PC software
- Traceable calibration certificate: 6 points for humidity, 1 point for temperature
- M10×1.5 cable gland included for mounting the probe head
-
Features
-
Six models for demanding industrial applications
-
Full 0 ... 100 %RH measurement, wide temperature range -40...+180 °C (-40...+356 °F)
-
Pressure tolerance up to 100 bar
-
Excellent performance in harsh conditions; good chemical tolerance
-
Corrosion-resistant IP65/IP66 housing
-
5-point calibration (certificate included)
-
Two analog outputs, calibrated (certificate included)
-
RS232, ASCII output
-
-
Features
- Intrinsically safe (Exi) for operation in up to Zone 0 / 20
- Measures RH and T and outputs an extensive range of calculated parameters: for a full list, see Technical data (page 5).
- Designed for harsh conditions
- Temperature range between −70 … +180 °C (−94 … +356 °F) depending on the probe option
- Vaisala HUMICAP sensor features high accuracy, excellent long-term stability, and negligible hysteresis
- Display options: graphical LCD display and non-display model
- Traceable calibration (certificate included)
- Compatible with Vaisala Insight PC software
-
Features
- Generates stable humidity and temperature conditions (<+-0.1% RH, <+-0.01 Degree Celsius)
- Calibration solution for the laboratory and on-site
- Humidity equilibrium typically in only 5 minutes for HG2-S, 15 minutes for HG2-XL
- Calibrate multiple probes simultaneously
- << Auto >> Automated calibration optional
- << Remote API >>logging and control with third party software (optional)
- Integrated FDA 21 CFR part 11 compliant Rotronic HW4 software
-
Features
- Numerical and graphical color display for up to 3 parameters
- IP65 metal housing
- Support for one Indigo compatible probe
- Tool-free locking wheel for the probe
- 24 V AC/DC power supply input
- 3 pre-configured analog outputs (mA or V)
- Service port on the front for connecting to Vaisala Insight PC software or Indigo80 handheld indicator
-
Features
- New & improved petroleum resistant scale, makes it easier to read.
- Choose 10 liter capacity fuel test measure cans.
- Provides a calibrated measure for testing the accuracy of fuel dispensing equipment.
- Stainless steel construction.
- Suitable for use with diesel proving can, biodiesel, petrol & AdBlue
- 304 stainless steel construction.
- Filling the measure to the “zero” mark will ensure an accurate amount of liters has been dispensed allowing the dispenser to be calibrated accordingly
- Full range of spares available on request
-
Features
- Online service for monitoring of measurement parameters such as humidity and temperature
- Secure cloud storage of data
- Management of measurement locations using an intuitive system of sites and locations
- Connect using a web browser on your mobile phone, tablet or computer
- Add devices and users based on your needs
- No device pairing needed, as devices are associated with a specific cloud account when they are purchased
-
Features
- LED digital display and operation panel
- Washable coarse air filter, easy to maintain
- PGMCC (R410a) brand compressor
- Both bucket and continuous hose drain
- Low temperature auto-defrost
- 1-24 hours timer on and timer off
- Automatic water full alarm and stop
- Universal castors, eave to move around
-
Product Features
- LED Digital display, timer on and off, auto-restart function
- 304 stainless steel mist maker, durable and efficient
- Low noise water proof fan, shield protected
- Superior transformer, ensure long time
- Water lack protection, manual/ auto water supply
- Compact design. easy to install and maintain
- Bottom castors, easy to move about
-
Features
- Low running and maintenance costs
- High evaporation efficiency, low pressure drop
- Now water treatment required, no water carry-over
- Compact design, no risk or over-saturation
- Self-clean function, low scaling safe and hygiene
- LGE digital display timer on and off, auto-restart function
- Water-lack protection, manual/ auto water supply
-
Features
- Nominal pressure: from 0 ... 4 mH2O up to 0 ... 250 mH2O
- Nominal temperature from 0 ... 30 °C up to 0 ... 70 °C
- Accuracy: 0,5 % FSO
- Diameter 26,5 mm
- Separate output signals for pressure and temperature ranges
- Excellent accuracy
- Easy handling
- Low maintenance and wiring costs
- Different kinds of cables
- Different kinds of seal materials
- Customer specific versions
- Energy Industry
- Environmental Industry
-
Features
- Nominal pressure: 0 ... 400 mbar up to 0 ... 60 bar
- Accuracy: 0.5 % FSO
- Pressure port G 3/4" flush
- Ceramic Sensor, Plant And Mechanical Engineering
- IS-version (only for 4... 20 mA / 2-wire): Ex ia = intrinsically safe for gases and dusts
- SIL 2 application according to IEC 61508 / IEC 61511
- Pressure port PVDF for aggressive media
- Different electrical and mechanical connections
- Customer specific versions
- Mechanical and Plant Engineering
- Energy Industry
- Medical Technology
- Environmental Industry
-
Features
- Nominal pressure: 0 ... 40 mbar up to 0 ... 20 bar
- Accuracy: 0.35 % (opt. 0.25 %) FSO
- Pressure port G 1 1/2" for pasty and polluted media
- Ceramic Sensor
- IS-version (Ex ia = intrinsically for gases and dusts)
- Pressure port PVDF for aggressive media
- Diaphragm pure ceramic (99,9 % Al2O3)
- Customer specific versions
- Mechanical and plant engineering
- Laboratory
- Environmental Industry