Loading...
  • Features
    • Nominal pressure range 0 ... 60 cmH2O up to 0 ... 100 mH2O
    • Accuracy: 0.1 %
    • Diameter 39.5 mm
    • HART®-communication (setting of offset. span and damping)
    • Permissible temperatures up to 85 °C
    • High long term stability
    Optional Features
    • IS-version (Ex ia = intrinsically safe for gas and dust)
    • Mounting with stainless steel pipe
    • Flange version
    • Diaphragm 99.9 % AI2O3
    • Accessories e.g. transmitter and mounting flanges and terminal clamp
    Areas of Application
    • Water Industry
    • Sewage Industry
    • fuel and Oil Industry
  • Features
    • Nominal pressure: 0 ... 40 cmH2O up to 0 ... 100 mH2O
    • Accuracy: 0,25 % / 0.35 % FSO
    • Diameter 39.5 mm
    • Especially for sewage, viscous and pasty media
    Areas of Application
    • Chemical Industry
    • Energy Industry
    • Environmental Industry
  • Features
    • Nominal pressure range 0 ... 60 cmH2O up to 0 ... 100 mH2O
    • Accuracy: 0.1 %
    • Diameter 39,5 mm
    • Cable and sensor section detachable
    • HART®-communication (setting of offset. span and damping)
    • Permissible temperatures up to 85 °C
    • High long term stability
    Optional Features
    • IS-version (Ex ia = intrinsically safe for gas and dust)
    • Cable protection via corrugated pipe
    • Diaphragm (AI2O3 99,9 %)
    • Accessories e.g. mounting flange with cable gland and terminal clamp
    Areas of Application
    • Chemical Industry
    • Energy Industry
    • Environmental Industry
  • Features
    • Nominal pressure: 0 ... 40 cmH2O up to 0 ... 100 mH2O
    • Accuracy: 0.35 % (opt. 0.25 %) FSO
    • Diameter 39.5 mm
    • Cable and sensor section detachable
    • Ceramic Sensor
    • Especially for sewage, viscous and pasty media
    Optional Features
    • IS-protection (Ex ia = intrinsically safe for gas and dust)
    • Cable protection via corrugated pipe
    • Diaphragm pure ceramic (99,9 % AI2O3)
    • Different kinds of cable
    • Different kinds of elastomeres
    Areas of Application
    • Chemical Industry
    • Energy Industry
    • Environmental Industry
     
  • Features
    • Nominal pressure: from 0 ... 4 mH2O up to 0 ... 250 mH2O
    • Nominal temperature from 0 ... 30 °C up to 0 ... 70 °C
    • Accuracy: 0,5 % FSO
    • Diameter 26,5 mm
    • Separate output signals for pressure and temperature ranges
    • Excellent accuracy
    • Easy handling
    • Low maintenance and wiring costs
    Optional Features
    • Different kinds of cables
    • Different kinds of seal materials
    • Customer specific versions
    Areas of Application
    • Energy Industry
    • Environmental Industry
  • Features
    • Ceramic Sensor, Stainless Steel Probe, Ø27mm,
    • Nominal pressure range from 0 ... 4 mH2O up to 0 ... 250 mH2O
    • Accuracy according to IEC 60770: 0.5 % FSO
  • Features
    • Ceramic Sensor, Ø17mm
    • Different cable material
    • Customer specific versions e.g. special pressure ranges
    • Nominal pressure range from 0 ... 6 mH2O up to 0 ... 200 mH2O
    Areas of Application
    • Energy Industry
    • Environmental Industry
  • Features
    • Supports multi-users and network environments
    • Calibration and asset management
    • Simple user interface
    • Scanning and printing of QR codes
    • User definable permissions and access levels
    • Support various units
    • Can calibrate variety pressure and temperature instruments
    • Can calibrate several instruments at a time
    • Calibration planning and scheduling
    • Certificate management and creation
    • Certificate customization
     
  • Features •Portable, only 3.7 lb • Minimal maintenance • Increase and decrease pressure smoothly • Hand-tight quick connectors Applications The Additel 925 Hydraulic Pressure Test Pump is designed to generate pressure from 85% vacuum to 6000 psi (400 bar) for the application requiring accurate pressure testing and calibration. It can be used in calibrating pressure gauges, transmitters, or other pressure measuring instruments.
  • Features
    • 5 feet of flexible hose
    • Rated 8,000 psi (550 bar) or 15,000 psi (1,000 bar)
    • Male NPT, BSP, or Metric to a variety of Female Quick Connectors
  • Features
    • Pneumatic range -15 to 1000 psi (-1.0 to 70 bar)
    • Hydraulic range -15 to 10,000 psi (-1.0 to 700 bar)
    • Easy to maintain
    • Configured with common pressure connections
       
  • Features
    • nominal pressure: 0 ... 400 mbar up to 0 ... 600 bar
    • accuracy: 0.5 % FSO
    • rotatable and configurable display module
    • indication of measured values on a 4-digit LED display
    • 1 or 2 independent PNP contacts, freely configurable
     Optional Features
    • IS-version Ex ia = itrinsically safe for gases
    • pressure port PVDF
    • customer specific versions
    Areas of Application
    • Mechanical and plant engineering mechanical and plant engineering
    • Environmental industry environmental industry
     
  • Features
    • Nominal pressure: 0 ... 100 mbar up to 0 ... 40 bar
    • Accuracy: 0.35 % (opt. 0.25 %) FSO
    • 1 or 2 independent PNP contacts, freely configurable
    • Indication of measured values on a 4-digit LED display
    • Rotatable and configurable display module
    • Hygienic process connections with flush stainless steel diaphragm
    • Configurable contacts (switch on / switch off points, hysteresis / window mode, switch on / switch off delay)
    Optional Features
    • IS-version - Ex ia = intrinsically safe for gases
    • Analog Output - 2-wire: 4 ... 20 mA, 3-wire: 4 ... 20 mA with Turn Down 1:5, 0 ... 10
    • Customer Specific Versions
    Areas of Application
    • Medical Technology
    • Food and Beverage
  • Features
    • Nominal pressure: 0 ... 100 mbar up to 0 ... 600 bar
    • Accuracy: 0.35 % (opt. 0.25 %) FSO
    • Indication of measured values on a 4-digit LED display
    • Rotatable and configurable display module
    • 1 or 2 independent PNP contacts, freely configurable
    Optional Features
    • IS-version - Ex ia = intrinsically safe for gases and dust
    • Pressure sensor welded
    • Customer Specific Versions
    Areas of Application
    •  Mechanical and plant engineering
    •  HVAC
    • Environmental industry
  • Features
    • Nominal pressure: 0 ... 100 mbar up to 0 ... 600 bar
    • Accuracy: 0,35 % FSO
    • Analog output (optional): 4 ... 20 mA or 0 ... 10 V
    • Indication of measured values on a 4-digit LED display
    • Parametrization by IO-Link or set menu system (VDMA-conform)
    • Rotatable and configurable display
    • 2 contacts
    Optional Features
    • different mechanical connections
    • customer specific versions
    Areas of Application
    • Mechanical and Plant Engineering
    • Hydraulics
    • Packaging and Paper Industry
     
  • Features
    • Nominal pressure: 0 ... 6 mbar up to 0 ... 1000 mbar
    • Accuracy: 0,35 % FSO
    • Aluminum housing
    • Rotatable and configurable display module
    • 4-digit LED display
    • Suited for non-aggressive gases and compressed air
    Optional Features
    • 1 / 2 PNP contacts
    • customer specific versions
    Areas of Application
    • Mechanical and plant engineering
    • HVAC
  • Features
    • Nominal pressure: 0 ... 2 bar up to 0 ... 400 bar
    • Accuracy: 1.5 % FSO
    • Display and housing rotatable
    • Up to 2 contacts
    • Configurable via display
    Optional Features
    • Analog output
    Areas of Application
    • Mechanical and Plant Engineering
    • Energy Industry
  • Features
    • Nominal pressure: 0 ... 6 bar up to 0 ... 600 bar
    • Accuracy: 0.5 % FSO
    • 1 analog output and up to 2 contacts
    • Display and housing rotatable
    • Perfect for oxygen applications
    Areas of Application
    • Mechanical and Plant Engineering
    • Energy Industry
    • Refrigeration Engineering
    • Medical Technology
    • Utility Vehicles / Mobile Hydraulics
  • Features
    • Nominal pressure: 0 ... 600 bar up to 0 ... 2200 bar
    • Accuracy: 0,35 % FSO
    • Indication of measured values on a 4-digit LED display
    • Rotatable and configurable display module
    • 1, 2 or 4 independent PNP contacts, freely configurable
    • Pressure sensor welded
    • Extremely robust and excellent longterm stability
    Optional Features
    • Adjustability of span and offset (4 ... 20 mA / 3-wire)
    • Customer specific versions
    Areas of Application
    • Mechanical and Plant Engineering
    • Utility Vehicles / Mobile Hydraulics
  • Features
    • Nominal pressure: 0 ... 10 mbar up to 0 ... 1000 mbar
    • Accuracy: 0.35 % FSO
    • Indication of measured values on a 4-digit LED display
    • Rotatable and configurable display module
    • 1, 2 or 4 independent PNP contacts, freely configurable
    Optional Features
    • IS-version: Ex ia = intrinsically safe for gases
    • Customer specific versions
    Areas of Application
    • Mechanical and Plant Engineering
    • HVAC
    • Laboratory
  • Features
    • Nominal pressure: 0 ... 6 bar up to 0 ... 600 bar
    • Accuracy: 0.5 % FSO
    • Indication of measured values on a 4-digit LED display
    • Rotatable and configurable display module
    • 1, 2 or 4 independent PNP contacts, freely configurable
    Optional Features
    • IS-version: Ex ia = intrinsically safe for gases
    • Oxygen application
    • Customer specific versions
    Areas of Application
    • Mechanical and Plant engineering
    • Energy Industry
    • Refrigeration Engineering
    • Medical Technology
    • Utility Vehicles / Mobile Hydraulics
  • Features
    • Nominal pressure: 0 ... 60 bar up to 0 ... 400 bar
    • Accuracy: 0.5 % FSO
    • 1, 2 or 4 independent PNP contacts, freely configurable
    • Rotatable and configurable display module
    • Indication of measured values on a 4-digit LED display
    Optional Features
    • IS-version - Ex ia = intrinsically safe for gases
    • Cooling element up to 300°C
    • Customer specific versions
    Areas of Application
    • Mechanical and Plant Engineering
    • Food and Beverage
  • Features
    • Nominal pressure: 0 ... 400 mbar up to 0 ... 600 bar
    • Accuracy: 0.5 % FSO
    • Indication of measured values on a 4-digit LED display
    • Rotatable and configurable display module
    • 1, 2 or 4 independent PNP contacts, freely configurable
    Optional Features
    • IS-version: Ex ia = intrinsically safe for gases
    • Pressure port PVDF
    • Customer specific versions
    Areas of Application
    • Mechanical and Plant Engineering
    • Environmental Industry
  • Features
    • Nominal pressure: 0 ... 100 mbar up to 0 ... 40 bar
    • Accuracy: 0.35 % (opt. 0.25 %) FSO
    • Rotatable and configurable display module
    • Indication of measured values on a 4-digit LED display
    • 1, 2 or 4 independent PNP contacts, freely configurable
    • Configurable contacts (switch on / switch off points, hysteresis / window mode, switch on / switch off delay)
    Optional Features
    • IS-version : Ex ia = intrinsically safe for gases
    • Customer specific versions
    • Analogue output
    Areas of Application
    • Medical Technology
    • Food and Beverage
  • Characteristics:
    • Stainless Steel Sensor
    • nominal pressure ranges from 0 ... 100 mbar up to 0 ... 600 bar
    • Accuracy according to IEC 60770: Standard: 0.35 % FSO option: 0.25 % FSO
  • Features
    • Nominal pressure: 0 ... 2 bar up to 0 ... 400 bar
    • Accuracy: 1 % FSO
    • 1 or 2 contacts
    • Configurable via PC or programming device P6
    • Diaphragm ceramic (96 %)
    Optional Features
    • Oil- and grease free application
    Areas of Application
    • Mechanical and plant engineering
    • Energy Industry
  • Characteristics:
    • Stainless Steel Sensor, Test Engineering, Machine And Plant Engineering
    • Differential pressure ranges from from 10 mbar up to 20 bar
    • Accuracy according to IEC 60770: 0.35 % FSO
  • Characteristics:
    • Silicon Sensor, HVAC Medical
    • Differential pressure ranges from 0 ... 1.6 mbar up to 0 ... 1000 mbar
    • Accuracy according to IEC 60770: 0.5% FSO BFSL
  • Characteristics
    • Piezoresistive silicon sensor
    • Differential pressure range 6 ... 1000 mbar
    • Application for for HVAC-applications
  • Characteristics:
    •  2 piezoresistive stainless steel sensors
    • Differential pressure from 0 ... 1 bar up to 0 ... 70 bar
    • Display and pressure port rotatable
  • Characteristics:
    • Silicon Sensor, Plant And Mechanical Engineering
    • Differential l pressure ranges from 0 ... 6 mbar up to 0 ... 1000 mbar
    • accuracy according to IEC 60770: 0.35 % / 1% / 2%
     
  • Characteristics:
    • Stainless Steel Sensor, Plant And Mechanical Engineerin
    • Differential pressure ranges from 0 ... 20 mbar up to 0 ... 16 bar
    • Accuracy according to IEC 60770: 0.5 % FSO
  • Characteristics
    • Stainless Steel Sensor
    • Nominal pressure ranges from 1 mbar up to 20 bar
    • Accuracy according to IEC 60770: 0.075 % FSO
    • Preferred areas of use are Process, Oil And Gas Industry
  • Characteristics
    • Ceramic Sensor
    • Nominal pressure ranges from 0 ... 160 mbar up to 0... 20 bar
    • Accuracy according to IEC 60770: 0.1 % FSO
    • Preferred areas of use for Process, Oil And Gas Industry
Go to Top