Loading...
  • Features
    • Nominal pressure: 0 ... 400 mbar up to 0 ... 60 bar
    • Accuracy: 0.5 % FSO
    • Pressure port G 3/4" flush
    • Ceramic Sensor, Plant And Mechanical Engineering
    Optional Features
    • IS-version (only for 4... 20 mA / 2-wire): Ex ia = intrinsically safe for gases and dusts
    • SIL 2 application according to IEC 61508 / IEC 61511
    • Pressure port PVDF for aggressive media
    • Different electrical and mechanical connections
    • Customer specific versions
    Areas of Application
    • Mechanical and Plant Engineering
    • Energy Industry
    • Medical Technology
    • Environmental Industry
  • Features
    • Nominal pressure: 0 ... 40 mbar up to 0 ... 20 bar
    • Accuracy: 0.35 % (opt. 0.25 %) FSO
    • Pressure port G 1 1/2" for pasty and polluted media
    • Ceramic Sensor
    Optional Features
    • IS-version (Ex ia = intrinsically for gases and dusts)
    • Pressure port PVDF for aggressive media
    • Diaphragm pure ceramic (99,9 % Al2O3)
    • Customer specific versions
    Areas of Application
    • Mechanical and plant engineering
    • Laboratory
    • Environmental Industry
  • Features
    • Nominal pressure: 0 ... 40 cmH2O up to 0 ... 100 mH2O
    • Accuracy: 0.35 % (opt. 0.25 %) FSO
    • Diameter 39.5 mm
    • Cable and sensor section detachable
    • Ceramic Sensor
    • Especially for sewage, viscous and pasty media
    Optional Features
    • IS-protection (Ex ia = intrinsically safe for gas and dust)
    • Cable protection via corrugated pipe
    • Diaphragm pure ceramic (99,9 % AI2O3)
    • Different kinds of cable
    • Different kinds of elastomeres
    Areas of Application
    • Chemical Industry
    • Energy Industry
    • Environmental Industry
     
  • Features
    • Nominal pressure range 0 ... 60 cmH2O up to 0 ... 100 mH2O
    • Accuracy: 0.1 %
    • Diameter 39,5 mm
    • Cable and sensor section detachable
    • HART®-communication (setting of offset. span and damping)
    • Permissible temperatures up to 85 °C
    • High long term stability
    Optional Features
    • IS-version (Ex ia = intrinsically safe for gas and dust)
    • Cable protection via corrugated pipe
    • Diaphragm (AI2O3 99,9 %)
    • Accessories e.g. mounting flange with cable gland and terminal clamp
    Areas of Application
    • Chemical Industry
    • Energy Industry
    • Environmental Industry
  • Features
    • Nominal pressure: 0 ... 40 cmH2O up to 0 ... 100 mH2O
    • Accuracy: 0,25 % / 0.35 % FSO
    • Diameter 39.5 mm
    • Especially for sewage, viscous and pasty media
    Areas of Application
    • Chemical Industry
    • Energy Industry
    • Environmental Industry
  • Features
    • Nominal pressure range 0 ... 60 cmH2O up to 0 ... 100 mH2O
    • Accuracy: 0.1 %
    • Diameter 39.5 mm
    • HART®-communication (setting of offset. span and damping)
    • Permissible temperatures up to 85 °C
    • High long term stability
    Optional Features
    • IS-version (Ex ia = intrinsically safe for gas and dust)
    • Mounting with stainless steel pipe
    • Flange version
    • Diaphragm 99.9 % AI2O3
    • Accessories e.g. transmitter and mounting flanges and terminal clamp
    Areas of Application
    • Water Industry
    • Sewage Industry
    • fuel and Oil Industry
  • Features
    • Nominal pressure: from 0 ... 4 mH2O up to 0 ... 100 mH2O
    • Acuracy: 0,35 % FSO
    • Diameter 22 mm
    • Excellent long term stability
    • Highly appropriated for wastewater, sludge and viscous media
    Optional Features
    • Diaphragm ceramics 99,9% Al2O3 (on request)
    • IS-version (in preparation), Ex ia = intrinsically safe for gases and dust
    • Mounting with stainless steel tube
    • Different kinds of cable
    • Different kinds of elastomer
    Areas of Application
    • Chemical Industry
    • Energy Industry
    • Environmental Industry
  • Features
    • Nominal pressure: from 0 ... 40 cmH2O up to 0 ... 200 mH2O
    • Diameter 39.5 mm
    • LR-certificate (Lloyd´s Register)
    • DNV ▪ GL Approval (Det Norske Veritas ▪ Germanischer Lloyd)
    • ABS-certificate (American Bureau of Shipping)
    • CCS-certificate (China Classification Society)
    • High overpressure resistanc
    • High long-term stability
    Optional Features
    • Diaphragm Al2O3 99.9 %
    • Different housing materials (stainless steel, CuNiFe)
    • IS-version, Ex ia = intrinsically safe for gas
    • Screw-in and flange version
    • Accessories e.g. assembling and probe flange, mounting clamp
    Areas of Application
    • Water Industry
    • Shipbuilding/ Offshore Industry
  • Features
    • Nominal pressure: 0 ... 60 cmH2O up to 0 ... 200 mH2O
    • Accuracy: 0.1 % FSO
    • Shipping approvals: American Bureau of Shipping (ABS), Bureau Veritas (BV), China Classification Society (CCS), Det Norske Veritas (DNV), Germanischer Lloyd (GL), Lloyd's Register (LR)
    • Diameter 39.5 mm
    • HART®-communication (setting of offset,span and damping)
    • High overpressure capability
    • High long term stability
    Optional Features
    • IS-version; Ex ia = intrinsically safe for gases and dusts
    • Diaphragm 99,9 % AI2O3
    • Different housing materials (stainless steel, CuNiFe)
    • Screw-in and flange version
    • Accessories e.g. assembling and probe flange, mounting clamp
    Areas of Application
    • Marine Industry
    • Shipbuilding/ Offshore Industry
    • Ceramic Sensor, Probe
    • Nominal pressure range from 0 ... 1 mH2O up to 0 ... 100 mH2O
    • Accuracy according to IEC 60770: 0.25 % FSO
     
  • Features
    • Ceramic Sensor, Flush, Plastic Probe
    • Nominal pressure: from 0 ... 6 mH2O up to 0 ... 200 mH2O
    • Diameter 21 mm
    • Excellent linearity
    • Excellent long term stability
    • Accuracy: 0,5% FSO
    • Suitable for hydrostatic level measurement e.g. 3/4" pipes
    Optional Features
    • Different cable materials
    • Customer specific versions, e.g. special pressure rang
    Areas of Applications
    • Chemical Industry
    • Environmental Industry
  • Features
    • Nominal pressure: 0 ... 4 mH2O up to 0 ... 100 mH2O
    • Accuracy: 0.5 % FSO
    • Diameter 35 mm
    • Excellent long term stability
    • Easy handling
    Optional Features
    • SIL 2 (safety integrity level) according to IEC 61508 / IEC 61511
    • Different kinds of cables and elastomeres
    • Customer specific version e.g. special pressure ranges
    Areas of Application
    • Chemical Industry
    • Environmental Industry
  • Features
    • Ceramic Sensor
    • Nominal pressure: 0 ... 1 mH2O up to 0 ... 100 mH2O
    • Accuracy: 0.35 % (opt. 0.25 %) FSO
    • Diameter 35mm
    • Diaphragm ceramics Al2O3 (99.9 %)
    • Cable and sensor section detachable
    • Excellent long term stability
    • Integrated lightning protection 8 kA gas discharge tube (8/20µsec); 4 kV surge l-l/l-e according to EN61000-4-5
    Optional Features
    • Mounting accessories
    • Different kinds of elastomer
    • Customer specific versions e. g. special pressure ranges
    Areas of Application
    • Chemical Industry
    • Environmental Industry
  • Features
    • High Purity Ceramic Sensor
    • Nominal pressure: 0 ... 40 cmH2O up to 0 ... 100 mH2O
    • Accuracy: 0.35 % (opt. 0.25 %) FSO
    • Diameter 45 mm
    • Chemical resistance
    • High over pressure capability
    • Pure ceramic sensor
    • Especially for tank level measurement of viscous and aggressive media
    • Housing material PP-HT or PVDF
    • Diaphragm ceramics Al2O3 (99.9 %)
    Optional Features
    • Different kinds of cable and seal materials
    • Prepared for mounting with pipe
    Areas of Application
    • Chemical Industry
    • Environmental Industry
  • Features
    • Ceramic Sensor
    • Nominal pressure: 0 ... 40 cmH2O up to 0 ... 100 mH2O
    • Accuracy: 0.35 % (opt. 0.25 %) FSO
    • Diameter 45 mm
    • Cable and sensor section detachable
    • Chemical resistance
    • Housing PP-HT
    • Integrated lightning protection and increased overvoltage protection; 8 kA gas discharge tube (8/20 μsec); 4 kV surge l-l/l-e according to EN61000-4-5
    Optional Features
    • Cable protection (on request)
    • Diaphragm pure ceramic (99,9 % AI2O3)
    • Different kinds of cables
    • Different kinds of elastomeres
    Areas of Application
    • Chemical Industry
    • Environmental Industry
  • Features
    • Stainless Steel Sensor
    • Nominal pressure: 0 ... 1 mH2O up to 0 ... 250 mH2O
    • Accuracy: 0.35 % (opt. 0.25 %) FSO
    • Diameter 19 mm for cramped areas e.g. 1" observation well
    • Small thermal effect
    • Excellent linearity
    • Excellent long term stability
    Optional Features
    • Different kinds of cable
    • Customer specific versions e.g. special pressure ranges
    Areas of Applications
    • Energy Industry
    • Environmental Industry
  • Features
    • Stainless Steel Sensor, Stainless Steel Probe
    • Nominal pressure: 0 ... 1 mH2O up to 0 ... 250 mH2
    • Accuracy: 0.35 % (opt. 0.25% / 0.1 %) FSO
    • Diameter 26.5 mm
    • Small thermal effect
    • Excellent long term stability
    • High Accuracy
  • Features
    • Nominal pressure: 0 ... 4 mH2O up to 0 ... 200 mH2O
    • Accuracy: 0,1 % FSO
    • Diameter 26,5 mm
    • Small thermal effect
    • Excellent accuracy
    • Excellent long term stability
    Optional Features
    • IS-version (Ex ia = intrinsically safe for gas and dust)
    • Drinking water certificate according to DVGW and KTW
    • Different kinds of cables
    • Different kinds of seal materials
    Areas of Application
    • Energy Industry
    • Oil and Gas Industry
    • Environmental Industry
  • Features
    • Nominal pressure: 0 ... 1 mH2O up to 0 ... 250 mH2O
    • Nominal temperature from 0 ... 30 °C up to 0 ... 70 °C
    • Accuracy: 0.35 % (opt. 0.25 %) FSO
    • Diameter 26.5 mm
    • Separate output signals for pressure and temperature ranges
    • Easy handling
    • low maintenance and wiring costs
    Optional Features
    • Drinking water certificate acc. to DVGW and KTW
    • Different kinds of cables
    • Different kinds of elastomers
    • Customer specific versions
    Areas of Application
    • Energy Industry
    • Environmental Industry
  • Features
    • Stainless Steel Sensor
    • Nominal pressure range from 0 ... 1 mH2O up to 0 ... 250 mH2O
    • Accuracy: 0.35 % (opt. 0.25% / 0.1 %) FSO
    • Diameter 35 mm
    • Cable and sensor section detachable
    • Excellent long term stability
    • High accuracy
    Optional Features
    • IS-version (Ex ia = intrinsically safe for gas and dust)
    • SIL 2 (Safety integrity level)
    • Customer specific versions
    • Mounting accessories as cable gland and terminal clamp of stainless steel
    • Different kinds of cables
    • Different kinds of seal materials
    Areas of Application
    • Energy Industry
    • Environmental Industry
     
  • Features
    • Stainless Steel Sensor
    • Nominal pressure range from 0 ... 4 mH2O up to 0 ... 200 mH2O
    • Accuracy: 0.1 % FSO
    • Diameter 35 mm
    • Cable and sensor section detachable
    • Thermal error in compensated range -20...70°C: 0.2 FSO TC 0.02% FSO/10K 0,02 % FSO / 10K
    • High accuracy
    • Communication connection
    • Turn-down 1:10
    Optional Features
    • IS-version (Ex ia = intrinsically safe for gas and dust)
    • Mounting accessories as cable gland and terminal clamp in stainless steel
    • Different kinds of cables
    • Different kinds of seal materials
    Areas of Application
    • Energy Industry
    • Environmental Industry
  • Features
    • Stainless Steel Sensor
    • Nominal pressure: 0 ...4 mH2O up to 0...200 mH2O
    • Accuracy: 0.1 % FSO
    • Diameter 35 mm
    • Cable and sensor section detachable
    • Thermal error in compensated range -20...70°C: 0.2 FSO TC 0.02% FSO/10K 0,02 % FSO / 10K
    • High Accuracy
    • Communication connection
    • turn-down 1:10
    Optional Features
    • IS-version (Ex ia = intrinsically safe for gases and dusts)
    • SIL 2 application according to IEC 61508 / IEC 61511
    • Different electrical connections
    • Customer specific versions e.g. special pressure range
    Areas of Application
    • Mechanical and Plant Engineering
    • Energy Industry
    • Environmental Industry
  • Features
    • Stainless Steel Sensor
    • Nominal pressure: 0 ... 400 mbar up to 0 ... 40 bar
    • Accuracy: 0.1 % FSO
    • Thermal error in compensated range -20 … 80 °C: 0.2 % FSO TC 0.02 % FSO / 10 K
    • Turn-down 1:10
    • Communication interface for adjusting of offset, span and damping
    Optional Features
    • IS-version (Ex ia = intrinsically safe for gases and dusts)
    • Adjustment of nominal pressure gauges (factory-provided)
    Areas of Application
    • Chemical Industry
    • Environmental Industry
  • Features
    • Stainless Steel Sensor
    • Nominal pressure: 0 ... 1 mH2O up to 0 ... 100 mH2O
    • Accuracy: 0.35 % (opt. 0.25 %) FSO
    • Diameter 35 mm
    • Cable and sensor section detachable
    • Excellent linearity
    • Small thermal effect
    • Integrated lightning protection and increased over voltage protection; 8 kA gas discharge tube (8/20 μsec); 4 kV surge l-l/l-e according to EN61000-4-5
    Optional Features
    • SIL 2 (safety integrity level) according to IEC 61508 / 61511
    • different kinds of cable and elastomeres
    • customer specific versions e.g. special pressure ranges
    Areas of Application
    • Energy Industry
    • Environmental Industry
  • Features
    • Large display for actual measurement
    • Max./ Min./ AVG indication
    • External temperature probe input
    • Battery status indication
    • Easy to use Window software
    • Visual and acoustic Hi-Lo Alarm
    • Adjustable logging interval from 1 second to 24hours
    • Easy to change battery
  • Features
    • Large display for actual measurement
    • Max./ Min./ AVG indication
    • External temperature probe input
    • Battery status indication
    • Easy to use Window software
    • Visual and acoustic Hi-Lo Alarm
    • Adjustable logging interval from 1 second to 24hours
    • Easy to change battery
  • Features:
    • Digital LCD display with backlight
    • 5.5% to 99.9% Range, 0~1 V
    • Stored up to 99 readings
    • 8 wood groups build in
    • Max./Min./Average values recalled
    • Built-in calibration
    • Changeable of extension probe
    • CE and RoHS Approved
     
  • Features:
    • Multi-color LED Bar-Graph readout
    • 5.5% to 100% Moisture Range
    • 0~1 Vdc Signal Output
    • Audible alert when value is detected
    • Built-in calibration function
    • Sturdy and durable moisture probe
    • CE and RoHS Approved
  • Features:
    • Built-in multifunction
    • Suitable different type of probes
    • 8 type of wood calibrations scales
    • Data-Hold, Max./Min.
    • Built-in calibration
    • Easy to operate, long-term stability
     
  • Features:
    • High accurate, fat response
    • Auto temperature compensation
    • Data-Hold / Max. / Min.
    • Auto power off
    • Built-in calibration (CAL) function
    • Drop/dust-proof, long term stability
     
  • Features:
    • Moisture measurement and control
    • 4~20 mA or 0~2 Vdc output
    • IP65 watertight enclosure, stainless steel probe
    • Custom calibration for measuring object
    • Wide supply voltage: 12 ~ 40 Vdc
    • Easy mounting and quick wiring
     
  • Features:
    • Moisture measurement and control
    • 4~20 mA or 0~2 Vdc output
    • IP65 watertight enclosure, stainless steel probe
    • Custom calibration for measuring object
    • Wide supply voltage: 12 ~ 40 Vdc
    • Easy mounting and quick wiring
     
  • Features
    •  IP66/IP68 water & dust resistant and 1.5 meters drop resistant case, rugged and durable designs
    • Compact, lightweight, small size with back clip, ergonomic and wearable design
    • Standard man down alarm, password protection, ID identification function
    • Real time value, TWA, STEL, MAX, MIN multiple numerical display
    • With self-test function, which can improve safety by automatic self-test
    • Standard 1000 data records and 100 events records
    • Support firmware upgrade remotely
    • With docking station to perform daily bump test and calibration (Optional)
    • Wireless data transmission including Lora, Bluetooth (Optional)
    • Low power consumption, battery run time is up to 24 hours per charge
  • Feature
    • Numerous connectivity solutions. Compact and lightweight.
    • Strong, protective, concussion-proof design.
    • Real-time gas concentration readings, location, alarm, and status enabled by state-ofthe-art wireless technology.
    • IP67 water and dust resistant case
    • Five-way local and remote notification of alarm conditions. Short bump test and calibration time. Global approval for worldwide acceptance
    • Filtered LEL sensor options to inhibit sensor poisoning. Compatible with Safety Communicator. Device Management with Honeywell Safety Suite
  • Features
    • IP68 water- and dust-resistant case
    • Low power consumption with 2 years standby time, no need battery charge and calibration
    • With Single /multi unit docking station to perform daily bump test and calibration (Optional)
    • With event and data logging function(optional)
    • With self-test function, which can improve safety by automatic self-test
    • Small size, light weight and with back clip for easily carry
    • 95db@30cm buzzer alarm, 2 high-bright red LED light alarm and vibration alarm
    • · Real time value, TWA, STEL, MAX,MIN multiple numerical display 
  • Features
    • Possibility to measure ambient dose equivalent rate (DER) of gamma radiation with the detector which is built in the control panel.
    • Automatic selection between measurement intervals and ranges.
    • Audio signalling of each registered gamma-quantum or beta particle.
    • Backlit indicator and control keys for operation in the dark.
    • Rechargeable lithium-ion battery charging by the built-in charger from: – internal solar battery; – 12 V automobile battery; – 220 V/50 Hz mains power using a voltage converter.
    • Multilevel indication of battery discharge.
    • Operates under conditions involving atmospheric precipitation, dusty atmosphere (IP67).
    • Analog indicator of radiation intensity.
    • Logging of up to 1500 measurement results tagged to location coordinates in the nonvolatile memory via infrared port to the PC (built-in GPS/GLONASS receiver).
    • Viewing of logged measurement results on the display.
    • Easy to operate even if wearing personal protection – rubber gloves.
    • Wide operating temperature range – from -30…+55°C.
    • Display temperature resistance – +95°C.
    Detector types
    • Gas-discharge Geiger-Muller counters without return run of counting response
    • Silicon beta radiation detector
Go to Top