- Available with field replaceable HUMICAP R2 sensor
- RH accuracy up to 0.8 %RH
- Temperature accuracy up to 0.1 °C (0.18 °F)
- Temperature measurement range −40 … +120 °C (−40 … +248 °F)
- Modbus RTU over RS-485
- Compatible with Indigo series transmitters and Insight PC software
-
Features
- RH accuracy up to 0.8 %RH, Temperature accuracy up to 0.1 °C (0.18 °F)
- Temperature measurement range -70 ... +180 °C (-94 ... +356 °F)
- Operating pressure 0 ... 10 MPa (0 ... 100 bar)
- Sensor purge provides superior chemical resistance
- Modbus RTU over RS-485
- Plug & play compatible with Indigo series of transmitters
- Traceable calibration certificate: 5 points for humidity, 1 point for temperature
-
Features
- RH accuracy up to 0.8 %RH, Temperature accuracy up to 0.1 °C (0.18 °F)
- Temperature measurement range -70 ... +180 °C (-94 ... +356 °F)
- 250 mm (9.84 in) probe allows easy process installation through insulation
- Sensor purge provides superior chemical resistance
- Modbus RTU over RS-485
- Plug & play compatible with Indigo series of transmitters
- Traceable calibration certificate: 5 points for humidity, 1 point for temperature
- Sintered AISI316L filter standard in delivery
-
Features
- RH accuracy up to 0.8 %RH, Temperature accuracy up to 0.1 °C (0.18 °F)
- Temperature measurement range -70 ... +180 °C (-94 ... +356 °F)
- Vapor and pressure proof construction
- Probe and sensor warming functions minimize condensation on probe
- Sensor purge provides superior chemical resistance
- Plug & play compatible with Indigo series of transmitters
- Modbus RTU over RS-485
- Traceable calibration certificate: 6 points for humidity, 1 point for temperature
-
Features
- Miniature probe head with low thermal mass for superior response time
- RH accuracy up to 0.8 %RH
- Temperature accuracy up to 0.1 °C (0.18 °F)
- Temperature measurement range −40 … +120 °C (−40 … +248 °F)
- Sensor purge provides superior chemical resistance
- Modbus RTU over RS-485
- Compatible with Indigo transmitters and Insight PC software
- Traceable calibration certificate: 6 points for humidity, 1 point for temperature
- M10×1.5 cable gland included for mounting the probe head
-
Features
-
Six models for demanding industrial applications
-
Full 0 ... 100 %RH measurement, wide temperature range -40...+180 °C (-40...+356 °F)
-
Pressure tolerance up to 100 bar
-
Excellent performance in harsh conditions; good chemical tolerance
-
Corrosion-resistant IP65/IP66 housing
-
5-point calibration (certificate included)
-
Two analog outputs, calibrated (certificate included)
-
RS232, ASCII output
-
-
Features
- Intrinsically safe (Exi) for operation in up to Zone 0 / 20
- Measures RH and T and outputs an extensive range of calculated parameters: for a full list, see Technical data (page 5).
- Designed for harsh conditions
- Temperature range between −70 … +180 °C (−94 … +356 °F) depending on the probe option
- Vaisala HUMICAP sensor features high accuracy, excellent long-term stability, and negligible hysteresis
- Display options: graphical LCD display and non-display model
- Traceable calibration (certificate included)
- Compatible with Vaisala Insight PC software
-
Features
- Generates stable humidity and temperature conditions (<+-0.1% RH, <+-0.01 Degree Celsius)
- Calibration solution for the laboratory and on-site
- Humidity equilibrium typically in only 5 minutes for HG2-S, 15 minutes for HG2-XL
- Calibrate multiple probes simultaneously
- << Auto >> Automated calibration optional
- << Remote API >>logging and control with third party software (optional)
- Integrated FDA 21 CFR part 11 compliant Rotronic HW4 software
-
Features
- Numerical and graphical color display for up to 3 parameters
- IP65 metal housing
- Support for one Indigo compatible probe
- Tool-free locking wheel for the probe
- 24 V AC/DC power supply input
- 3 pre-configured analog outputs (mA or V)
- Service port on the front for connecting to Vaisala Insight PC software or Indigo80 handheld indicator
-
Features
- New & improved petroleum resistant scale, makes it easier to read.
- Choose 10 liter capacity fuel test measure cans.
- Provides a calibrated measure for testing the accuracy of fuel dispensing equipment.
- Stainless steel construction.
- Suitable for use with diesel proving can, biodiesel, petrol & AdBlue
- 304 stainless steel construction.
- Filling the measure to the “zero” mark will ensure an accurate amount of liters has been dispensed allowing the dispenser to be calibrated accordingly
- Full range of spares available on request
-
Features
- Online service for monitoring of measurement parameters such as humidity and temperature
- Secure cloud storage of data
- Management of measurement locations using an intuitive system of sites and locations
- Connect using a web browser on your mobile phone, tablet or computer
- Add devices and users based on your needs
- No device pairing needed, as devices are associated with a specific cloud account when they are purchased
-
Features
- LED digital display and operation panel
- Washable coarse air filter, easy to maintain
- PGMCC (R410a) brand compressor
- Both bucket and continuous hose drain
- Low temperature auto-defrost
- 1-24 hours timer on and timer off
- Automatic water full alarm and stop
- Universal castors, eave to move around
-
Product Features
- LED Digital display, timer on and off, auto-restart function
- 304 stainless steel mist maker, durable and efficient
- Low noise water proof fan, shield protected
- Superior transformer, ensure long time
- Water lack protection, manual/ auto water supply
- Compact design. easy to install and maintain
- Bottom castors, easy to move about
-
Features
- Low running and maintenance costs
- High evaporation efficiency, low pressure drop
- Now water treatment required, no water carry-over
- Compact design, no risk or over-saturation
- Self-clean function, low scaling safe and hygiene
- LGE digital display timer on and off, auto-restart function
- Water-lack protection, manual/ auto water supply
-
Features
- Nominal pressure: from 0 ... 4 mH2O up to 0 ... 250 mH2O
- Nominal temperature from 0 ... 30 °C up to 0 ... 70 °C
- Accuracy: 0,5 % FSO
- Diameter 26,5 mm
- Separate output signals for pressure and temperature ranges
- Excellent accuracy
- Easy handling
- Low maintenance and wiring costs
- Different kinds of cables
- Different kinds of seal materials
- Customer specific versions
- Energy Industry
- Environmental Industry
-
Features
- Nominal pressure: 0 ... 400 mbar up to 0 ... 60 bar
- Accuracy: 0.5 % FSO
- Pressure port G 3/4" flush
- Ceramic Sensor, Plant And Mechanical Engineering
- IS-version (only for 4... 20 mA / 2-wire): Ex ia = intrinsically safe for gases and dusts
- SIL 2 application according to IEC 61508 / IEC 61511
- Pressure port PVDF for aggressive media
- Different electrical and mechanical connections
- Customer specific versions
- Mechanical and Plant Engineering
- Energy Industry
- Medical Technology
- Environmental Industry
-
Features
- Nominal pressure: 0 ... 40 mbar up to 0 ... 20 bar
- Accuracy: 0.35 % (opt. 0.25 %) FSO
- Pressure port G 1 1/2" for pasty and polluted media
- Ceramic Sensor
- IS-version (Ex ia = intrinsically for gases and dusts)
- Pressure port PVDF for aggressive media
- Diaphragm pure ceramic (99,9 % Al2O3)
- Customer specific versions
- Mechanical and plant engineering
- Laboratory
- Environmental Industry
-
Features
- Nominal pressure: 0 ... 40 cmH2O up to 0 ... 100 mH2O
- Accuracy: 0.35 % (opt. 0.25 %) FSO
- Diameter 39.5 mm
- Cable and sensor section detachable
- Ceramic Sensor
- Especially for sewage, viscous and pasty media
- IS-protection (Ex ia = intrinsically safe for gas and dust)
- Cable protection via corrugated pipe
- Diaphragm pure ceramic (99,9 % AI2O3)
- Different kinds of cable
- Different kinds of elastomeres
- Chemical Industry
- Energy Industry
- Environmental Industry
-
Features
- Nominal pressure range 0 ... 60 cmH2O up to 0 ... 100 mH2O
- Accuracy: 0.1 %
- Diameter 39,5 mm
- Cable and sensor section detachable
- HART®-communication (setting of offset. span and damping)
- Permissible temperatures up to 85 °C
- High long term stability
- IS-version (Ex ia = intrinsically safe for gas and dust)
- Cable protection via corrugated pipe
- Diaphragm (AI2O3 99,9 %)
- Accessories e.g. mounting flange with cable gland and terminal clamp
- Chemical Industry
- Energy Industry
- Environmental Industry
-
Features
- Nominal pressure range 0 ... 60 cmH2O up to 0 ... 100 mH2O
- Accuracy: 0.1 %
- Diameter 39.5 mm
- HART®-communication (setting of offset. span and damping)
- Permissible temperatures up to 85 °C
- High long term stability
- IS-version (Ex ia = intrinsically safe for gas and dust)
- Mounting with stainless steel pipe
- Flange version
- Diaphragm 99.9 % AI2O3
- Accessories e.g. transmitter and mounting flanges and terminal clamp
- Water Industry
- Sewage Industry
- fuel and Oil Industry
-
Features
- Nominal pressure: from 0 ... 4 mH2O up to 0 ... 100 mH2O
- Acuracy: 0,35 % FSO
- Diameter 22 mm
- Excellent long term stability
- Highly appropriated for wastewater, sludge and viscous media
- Diaphragm ceramics 99,9% Al2O3 (on request)
- IS-version (in preparation), Ex ia = intrinsically safe for gases and dust
- Mounting with stainless steel tube
- Different kinds of cable
- Different kinds of elastomer
- Chemical Industry
- Energy Industry
- Environmental Industry
-
Features
- Nominal pressure: from 0 ... 40 cmH2O up to 0 ... 200 mH2O
- Diameter 39.5 mm
- LR-certificate (Lloyd´s Register)
- DNV ▪ GL Approval (Det Norske Veritas ▪ Germanischer Lloyd)
- ABS-certificate (American Bureau of Shipping)
- CCS-certificate (China Classification Society)
- High overpressure resistanc
- High long-term stability
- Diaphragm Al2O3 99.9 %
- Different housing materials (stainless steel, CuNiFe)
- IS-version, Ex ia = intrinsically safe for gas
- Screw-in and flange version
- Accessories e.g. assembling and probe flange, mounting clamp
- Water Industry
- Shipbuilding/ Offshore Industry
-
Features
- Nominal pressure: 0 ... 60 cmH2O up to 0 ... 200 mH2O
- Accuracy: 0.1 % FSO
- Shipping approvals: American Bureau of Shipping (ABS), Bureau Veritas (BV), China Classification Society (CCS), Det Norske Veritas (DNV), Germanischer Lloyd (GL), Lloyd's Register (LR)
- Diameter 39.5 mm
- HART®-communication (setting of offset,span and damping)
- High overpressure capability
- High long term stability
- IS-version; Ex ia = intrinsically safe for gases and dusts
- Diaphragm 99,9 % AI2O3
- Different housing materials (stainless steel, CuNiFe)
- Screw-in and flange version
- Accessories e.g. assembling and probe flange, mounting clamp
- Marine Industry
- Shipbuilding/ Offshore Industry
-
Features
- Ceramic Sensor, Flush, Plastic Probe
- Nominal pressure: from 0 ... 6 mH2O up to 0 ... 200 mH2O
- Diameter 21 mm
- Excellent linearity
- Excellent long term stability
- Accuracy: 0,5% FSO
- Suitable for hydrostatic level measurement e.g. 3/4" pipes
- Different cable materials
- Customer specific versions, e.g. special pressure rang
- Chemical Industry
- Environmental Industry
-
Features
- Nominal pressure: 0 ... 4 mH2O up to 0 ... 100 mH2O
- Accuracy: 0.5 % FSO
- Diameter 35 mm
- Excellent long term stability
- Easy handling
- SIL 2 (safety integrity level) according to IEC 61508 / IEC 61511
- Different kinds of cables and elastomeres
- Customer specific version e.g. special pressure ranges
- Chemical Industry
- Environmental Industry
-
Features
- Ceramic Sensor
- Nominal pressure: 0 ... 1 mH2O up to 0 ... 100 mH2O
- Accuracy: 0.35 % (opt. 0.25 %) FSO
- Diameter 35mm
- Diaphragm ceramics Al2O3 (99.9 %)
- Cable and sensor section detachable
- Excellent long term stability
- Integrated lightning protection 8 kA gas discharge tube (8/20µsec); 4 kV surge l-l/l-e according to EN61000-4-5
- Mounting accessories
- Different kinds of elastomer
- Customer specific versions e. g. special pressure ranges
- Chemical Industry
- Environmental Industry
-
Features
- High Purity Ceramic Sensor
- Nominal pressure: 0 ... 40 cmH2O up to 0 ... 100 mH2O
- Accuracy: 0.35 % (opt. 0.25 %) FSO
- Diameter 45 mm
- Chemical resistance
- High over pressure capability
- Pure ceramic sensor
- Especially for tank level measurement of viscous and aggressive media
- Housing material PP-HT or PVDF
- Diaphragm ceramics Al2O3 (99.9 %)
- Different kinds of cable and seal materials
- Prepared for mounting with pipe
- Chemical Industry
- Environmental Industry
-
Features
- Ceramic Sensor
- Nominal pressure: 0 ... 40 cmH2O up to 0 ... 100 mH2O
- Accuracy: 0.35 % (opt. 0.25 %) FSO
- Diameter 45 mm
- Cable and sensor section detachable
- Chemical resistance
- Housing PP-HT
- Integrated lightning protection and increased overvoltage protection; 8 kA gas discharge tube (8/20 μsec); 4 kV surge l-l/l-e according to EN61000-4-5
- Cable protection (on request)
- Diaphragm pure ceramic (99,9 % AI2O3)
- Different kinds of cables
- Different kinds of elastomeres
- Chemical Industry
- Environmental Industry
-
Features
- Stainless Steel Sensor
- Nominal pressure: 0 ... 1 mH2O up to 0 ... 250 mH2O
- Accuracy: 0.35 % (opt. 0.25 %) FSO
- Diameter 19 mm for cramped areas e.g. 1" observation well
- Small thermal effect
- Excellent linearity
- Excellent long term stability
- Different kinds of cable
- Customer specific versions e.g. special pressure ranges
- Energy Industry
- Environmental Industry
-
Features
- Nominal pressure: 0 ... 4 mH2O up to 0 ... 200 mH2O
- Accuracy: 0,1 % FSO
- Diameter 26,5 mm
- Small thermal effect
- Excellent accuracy
- Excellent long term stability
- IS-version (Ex ia = intrinsically safe for gas and dust)
- Drinking water certificate according to DVGW and KTW
- Different kinds of cables
- Different kinds of seal materials
- Energy Industry
- Oil and Gas Industry
- Environmental Industry
-
Features
- Nominal pressure: 0 ... 1 mH2O up to 0 ... 250 mH2O
- Nominal temperature from 0 ... 30 °C up to 0 ... 70 °C
- Accuracy: 0.35 % (opt. 0.25 %) FSO
- Diameter 26.5 mm
- Separate output signals for pressure and temperature ranges
- Easy handling
- low maintenance and wiring costs
- Drinking water certificate acc. to DVGW and KTW
- Different kinds of cables
- Different kinds of elastomers
- Customer specific versions
- Energy Industry
- Environmental Industry
-
Features
- Stainless Steel Sensor
- Nominal pressure range from 0 ... 1 mH2O up to 0 ... 250 mH2O
- Accuracy: 0.35 % (opt. 0.25% / 0.1 %) FSO
- Diameter 35 mm
- Cable and sensor section detachable
- Excellent long term stability
- High accuracy
- IS-version (Ex ia = intrinsically safe for gas and dust)
- SIL 2 (Safety integrity level)
- Customer specific versions
- Mounting accessories as cable gland and terminal clamp of stainless steel
- Different kinds of cables
- Different kinds of seal materials
- Energy Industry
- Environmental Industry
-
Features
- Stainless Steel Sensor
- Nominal pressure range from 0 ... 4 mH2O up to 0 ... 200 mH2O
- Accuracy: 0.1 % FSO
- Diameter 35 mm
- Cable and sensor section detachable
- Thermal error in compensated range -20...70°C: 0.2 FSO TC 0.02% FSO/10K 0,02 % FSO / 10K
- High accuracy
- Communication connection
- Turn-down 1:10
- IS-version (Ex ia = intrinsically safe for gas and dust)
- Mounting accessories as cable gland and terminal clamp in stainless steel
- Different kinds of cables
- Different kinds of seal materials
- Energy Industry
- Environmental Industry
-
Features
- Stainless Steel Sensor
- Nominal pressure: 0 ...4 mH2O up to 0...200 mH2O
- Accuracy: 0.1 % FSO
- Diameter 35 mm
- Cable and sensor section detachable
- Thermal error in compensated range -20...70°C: 0.2 FSO TC 0.02% FSO/10K 0,02 % FSO / 10K
- High Accuracy
- Communication connection
- turn-down 1:10
- IS-version (Ex ia = intrinsically safe for gases and dusts)
- SIL 2 application according to IEC 61508 / IEC 61511
- Different electrical connections
- Customer specific versions e.g. special pressure range
- Mechanical and Plant Engineering
- Energy Industry
- Environmental Industry
-
Features
- Stainless Steel Sensor
- Nominal pressure: 0 ... 400 mbar up to 0 ... 40 bar
- Accuracy: 0.1 % FSO
- Thermal error in compensated range -20 … 80 °C: 0.2 % FSO TC 0.02 % FSO / 10 K
- Turn-down 1:10
- Communication interface for adjusting of offset, span and damping
- IS-version (Ex ia = intrinsically safe for gases and dusts)
- Adjustment of nominal pressure gauges (factory-provided)
- Chemical Industry
- Environmental Industry
-
Features
- Stainless Steel Sensor
- Nominal pressure: 0 ... 1 mH2O up to 0 ... 100 mH2O
- Accuracy: 0.35 % (opt. 0.25 %) FSO
- Diameter 35 mm
- Cable and sensor section detachable
- Excellent linearity
- Small thermal effect
- Integrated lightning protection and increased over voltage protection; 8 kA gas discharge tube (8/20 μsec); 4 kV surge l-l/l-e according to EN61000-4-5
- SIL 2 (safety integrity level) according to IEC 61508 / 61511
- different kinds of cable and elastomeres
- customer specific versions e.g. special pressure ranges
- Energy Industry
- Environmental Industry
-
Features
- IP66/IP68 water & dust resistant and 1.5 meters drop resistant case, rugged and durable designs
- Compact, lightweight, small size with back clip, ergonomic and wearable design
- Standard man down alarm, password protection, ID identification function
- Real time value, TWA, STEL, MAX, MIN multiple numerical display
- With self-test function, which can improve safety by automatic self-test
- Standard 1000 data records and 100 events records
- Support firmware upgrade remotely
- With docking station to perform daily bump test and calibration (Optional)
- Wireless data transmission including Lora, Bluetooth (Optional)
- Low power consumption, battery run time is up to 24 hours per charge
-
Feature
- Numerous connectivity solutions. Compact and lightweight.
- Strong, protective, concussion-proof design.
- Real-time gas concentration readings, location, alarm, and status enabled by state-ofthe-art wireless technology.
- IP67 water and dust resistant case
- Five-way local and remote notification of alarm conditions. Short bump test and calibration time. Global approval for worldwide acceptance
- Filtered LEL sensor options to inhibit sensor poisoning. Compatible with Safety Communicator. Device Management with Honeywell Safety Suite
-
Features
- IP68 water- and dust-resistant case
- Low power consumption with 2 years standby time, no need battery charge and calibration
- With Single /multi unit docking station to perform daily bump test and calibration (Optional)
- With event and data logging function(optional)
- With self-test function, which can improve safety by automatic self-test
- Small size, light weight and with back clip for easily carry
- 95db@30cm buzzer alarm, 2 high-bright red LED light alarm and vibration alarm
- · Real time value, TWA, STEL, MAX,MIN multiple numerical display
-
Features
- Possibility to measure ambient dose equivalent rate (DER) of gamma radiation with the detector which is built in the control panel.
- Automatic selection between measurement intervals and ranges.
- Audio signalling of each registered gamma-quantum or beta particle.
- Backlit indicator and control keys for operation in the dark.
- Rechargeable lithium-ion battery charging by the built-in charger from: – internal solar battery; – 12 V automobile battery; – 220 V/50 Hz mains power using a voltage converter.
- Multilevel indication of battery discharge.
- Operates under conditions involving atmospheric precipitation, dusty atmosphere (IP67).
- Analog indicator of radiation intensity.
- Logging of up to 1500 measurement results tagged to location coordinates in the nonvolatile memory via infrared port to the PC (built-in GPS/GLONASS receiver).
- Viewing of logged measurement results on the display.
- Easy to operate even if wearing personal protection – rubber gloves.
- Wide operating temperature range – from -30…+55°C.
- Display temperature resistance – +95°C.
- Gas-discharge Geiger-Muller counters without return run of counting response
- Silicon beta radiation detector