Loading...
  • Main Function
    • Heating / cooling output
    • High / Low alarm output
    • Precise temperature control
    • Sensor correction
    • Sensor error detection
    • Data back up
    • Minimum on/off maintaining time setup
    • RS485 communication (MODBUS)
    • Transmission output
     
  • Main Function
    • Humidification/dehumidification output
    • High/Low alarm output
    • Min. on/off maintaining time setup
    • Selection on/off output when sensor error occurs
    • Sensor correction
    • Sensor error detection
    • Selection of displaying decimal point
     
  • Main Function
    • Heating / cooling output
    • Independent timer output
    • High / Low alarm output
    • Defrost output
    • Precise temperature control
    • Sensor correction
    • Sensor error detection
    • Data back up
    • Minimum on/off maintaining time setup
    • RS485 communication (MODBUS)
    • Transmission output
    • Auto-output operation cycle settable in case of sensor error
  • Features
    • Humidification (heating)
    • Dehumidification (cooling) output
    • High/Low alarm output
    • Min. on/off maintaining time setup
    • Selection on/off output when sensor error occurs
    • Sensor correction
    • Sensor error detection
    • Relay output manual control
    • Transmission output
    • RS485 communication (MODBUS)
  • Main Function
    • Heating / cooling output
    • Independent timer output
    • High / Low alarm output
    • Defrost output
    • Precise temperature control
    • Sensor correction
    • Sensor error detection
    • Data back up
    • Minimum on/off maintaining time setup
    • RS485 communication (MODBUS)
    • Transmission output
    • Auto-output operation cycle settable in case of sensor error
     
  • Main Function
    • Defrosting (auto / manual)
    • Defrosting stop delay
    • 2 air inlet/outlet sensors
    • One sensor for defrost recovery
    • High / Low alarm output
    • Indicator (FixView) connection
    • RS485 communication (MODBUS)
     
  • Main Function
    • Defrosting (auto / manual)
    • Defrosting stop delay
    • Evaporation fan control
    • Air inlet/outlet sensor: 2EA
    • Defrost recovery sensor: 1EA
    • Virtual temperature sensor computing
    • Door open alarm
    • Emergency call
    • Night operation
    • High (low) temperature alarm output
    • RS485 communication (MODBUS)
     
  • Main Function
    • Uniform step control
    • Operation with intelligent shift high / low alarm output
    • Sensor correction / Sensor error detection
    • Transmission output
    • RS485 communication (MODBUS)
     
  • Main Function
    • Output controllable based on measured pressure value (increase and decrease)
    • Alternative operation available between freezing exclusive model and booster
    • Pump unit control model
    • RS485 MODBUS
     
  • Main Function
    • Efficient defrosting in geothermy heat pump system
    • Defrosting execution by measuring of ambient humidity and temperature
     
  • Main Function
    • Defrosting (auto / manual)
    • Fan control
    • Efficient delay
    • Room temperature sensor: 1EA
    • Defrost sensor: 1EA
    • High (low) temperature alarm output
    • Room temperature transmission output (4~20 mA)
    • RS485 communication (MODBUS)
     
  • Main Function
    • 3 stage fan speed controllable
    • 4 kind (stop / high / middle / low) airflow choosable
    • Unification of temperature control function
    • Data backup
    • Self diagnostic
    • RS485 communication (MODBUS)
     
  • Main Function
    • PID degree of superheat control through defense and safety compensation
    • Degree of superheat control for various refrigerant
    • PMW (opening ratios control)
    • Remote operation
    • Transmission output
    • RS485 communication (MODBUS)
     
  • Main Function
    • Total control and detection (protection) for freezers
    • Function of start, restart, pump down, alarm delay timer
    • Discharge gas detection (high & low temperature)
    • Individual alarm message (OC, HP, LP, OP, INT)
    • RS485 communication (MODBUS)
     
  • Main Function
    • Embedded run/stop switch, motor on/off, load run, auto-stop, manual stop, operation delay, load delay, embedded timer
    • Pressure / temperature high level
    • Temperature low level (standby for starting)
    • Interlock input signal (emergency switch, OCR reverse phase)
    • Usable thermometer and manometer
    • RS485 communication (MODBUS)
     
  • Main Function
    • Embedded run/stop switch, motor on/off, load run, auto-stop, manual stop, operation delay, load delay, embedded timer
    • Pressure / temperature high level
    • Temperature low level (standby for starting)
    • Interlock input signal (emergency switch, OCR reverse phase)
    • Usable thermometer and manometer
    • RS485 communication (MODBUS)
     
  • Features
    •  Measurement accuracy 1%
    • Converter IP rating IP 67, transducer IP rating IP 68
    • Wide measurement range, pipe size from DN15 mm to DN6000 mm
    • Connect the temperature transducer can finish the heat / energy measurement
  • Features
    •  One pair (red, black) comfort grip probes with silicone insulated, right-angle test leads
    • Recommended for µV measurements
    • CAT II 1000 V, 10 A rating
    • CAT III 1000 V, CAT IV 600V only with protective cap
  • Features
    • Identify complex signal problems fast
    • Supports accurate measurements on VFDs using a low-pass filter
    • Captures intermittents as fast as 250 µS with Peak Capture
  • Features
    • Large display
    • Backlight for work in dim areas
    • Min / Max to record signal fluctuations
    • Ergonomic overmolded housing with integrated probe holders
    • Free your hands with the optional TPAK magnetic hanger
    • Auto and Manual ranging
    • Meets Measurement Category 1000 V CAT III and Category IV 600 V safety standards
  • Features
    • Electric pump for one handed pressure calibration
    • Best in class pressure measurement uncertainty of 0.025 %
    • Measure and source mA with best in class 0.015 % accuracy
    • Precision pressure adjust vernier
    • Variable release rate bleed valve for easy pressure adjustment
    • Ideal performance for high accuracy transmitter calibration
    • 30 PSI and 100 PSI pressure ranges
    • Programmable pump limit: - Eliminates over-pressurization - Allows the user to program target pressures for pumping
    • Extended measurement range with any of twenty-nine (29) 700Pxx Pressure Modules
    • Source mA with simultaneous pressure measurement to
    • test valves and I/Ps
    • Simulate mA signals to troubleshoot 4-20 mA loops
    • Test pressure switches with built in switch test function
    • Power transmitters during test using 24 V loop supply
    • Proven cleanout ports reduce pump failures
  • Features
    •  True-rms AC/DC current, voltage, temperature, frequency
    • Clamp meter, test leads, K-type thermocouple and soft case
    • Versatile tool performs most front-line measurement tasks
  • Features
    • Rugged, reliable basic True-RMS clamp meter for measuring current up to 400 A
    • Measures AC current to 400 A
    • Measures AC voltage and DC voltage to 600 V
    • Provides True RMS AC voltage and current for accurate measurements on non-linear signals
    • Measures resistance to 4 kΩ with continuity detection
  • Features
    • Rugged, reliable basic True-RMS clamp meter for measuring current up to 400 A
    • Measures AC current to 400 A
    • Measures AC voltage and DC voltage to 600 V
    • Provides True RMS AC voltage and current for accurate measurements on non-linear signals
    • Measures resistance to 4 kΩ with continuity detection
  • Features
    • IP 67 waterproof & dustproof protection, completely sealed for use in harsh environments
    • Designed to withstand 3 meter drop (with holster)
    • Unique function for accurate
  • Features
    • 1000V AC/DC; 10A AC/DC (with test leads and current jacks); resistance to 50 MΩ; capacitance to 10,000 μF, frequency to 100 kHz; temperature from -40 ℃ to 400 ℃
    • Robust, fast and accurate with manual and automatic ranging, Display Hold, Auto Hold, and Min/Max-Average recording
    • Backlit digital display, analog bar graph, and built-in temperature measurements with included thermocouple.
  • Features
    • True-RMS digital multimeter with the features professional technicians prefer
    • Increases productivity with manual and automatic ranging, Display Hold, Auto Hold, and Min/Max-average recording
    • Measures AC and DC voltage to 1000 V
    • Delivers accurate True-RMS AC current and voltage plus frequency, capacitance, resistance, continuity and diode measurements
    • Safety rated CAT III 1000 V, CAT IV 600 V
  • Features
    • PI/DAR timed ratio tests
    • Live circuit detection prevents insulation test if voltage >30 V is detected for added user protection
    • VFD low-pass filter for accurate motor drive measurements
    • Auto-discharge of capacities voltage for added user protection
    • Insulation test of 0.01 MΩ to 2 GΩ
    • Insulation test voltages of 50, 100, 250, 500 V for many applications
    • AC/DC voltage, DC millivolts, AC/DC milliamps, resistance (Ω), continuity
    • Capacitance, diode test, temperature, Min/Max, frequency (Hz)
    • Auto power off to save battery power
    • CAT III 1000 V, CAT IV 600 V measurement category
    • Large display with backlight
    • Safety first. Keep yourself out of harm's way by monitoring your test measurements remotely
    • Prove your job is done right by quickly seeing and sharing measurement results wirelessly with your smartphone
    • Quickly find problems by saving and comparing measurements over time on a wireless device
  • Features
    • Auto discharge of capacitive voltage
    • AC/DC voltage
    • DC millivolts
    • AC/DC milliamps
    • Continuity
    • Auto power off to save battery power
    • True RMS
    • Large display with backlight
    • Live circuit detection prevents insulation test if voltage <30 V is detected for added user protection
    • CAT III 1000V, CAT IV 600V measurement category
  • Features
    • Rugged, compact advanced insulation resistance tester for electrical contractors and industrial and commercial electricians
    • Automatically calculates Polarization Index and Dielectric Absorption Ratio
    • Makes repetitive tests simple and easy with a Compare (Pass/Fail) function
    • Offers multiple insulation test voltages: 50 V, 100 V, 250 V, 500 V, and 1000 V
  • Features
    • Compact, true-rms digital multimeter for electricians
    • Includes multimeter, 4mm silicone test leads, holster and manual
    • Integrated non-contact voltage detection keeps you safe
    • Prevent false readings from ghost voltage with selectable low-impedance mode
  • Features
    • Digital multimeter designed specifically for HVAC professionals
    • Includes built-in thermometer to measure temperature from -40°C to 400°C (-40°F to 752°F)
    • Provides microamps to test flame sensors
    • Features low input impedance to helps prevent false readings due to ghost voltage
    • Presents a large white LED backlight for working in poorly lit areas
  • Features 
    • Compact True-RMS digital multimeter for field service
    • Includes: meter, holster, 4 mm silicone test lead set
    • Easy one-handed operation of the meter
    • Min/Max/Average to record signal fluctuations
  • Features
    • Ideal Digital Multimeter for “go/no-go” testing
    • Features AutoVolt automatic AC/DC voltage selection
    • Includes low input impedance to help prevent false readings due to ghost voltage
    • Presents a large white LED backlight for working in poorly lit areas
    • Measures resistance and continuity
    • Provides Min/Max/Average with elapsed time to record signal fluctuations
  • Features
    • VCHEK LoZ low impedance measurement function to test for either AC or DC voltage, or show continuity if voltage is not detected.
    • Large backlit display
    • CAT IV 600 V safety rated
  • Features
    • Precise Measurement : Utilizes a unique Venturi tube structure
    • 2″ LCD Screen : Easily configurable with buttons
    • Display Features : Shows instant and cumulative measurements; screen rotates 90 degrees for easy viewing
    • Multiple Pipe Diameters Available : (DN15 / DN25 / DN40 / DN50) for easy installation
    • Accuracy : ±2.0% F.S., pipeline withstand pressure of 16 bar
    • Multiple Outputs: Analog output / Relay / RS-485

Title