Pressure Switches

  • Characteristics:
    • Stainless Steel Sensor
    • nominal pressure ranges from 0 ... 100 mbar up to 0 ... 600 bar
    • Accuracy according to IEC 60770: Standard: 0.35 % FSO option: 0.25 % FSO
  • Features
    • Nominal pressure: 0 ... 100 mbar up to 0 ... 40 bar
    • Accuracy: 0.35 % (opt. 0.25 %) FSO
    • Rotatable and configurable display module
    • Indication of measured values on a 4-digit LED display
    • 1, 2 or 4 independent PNP contacts, freely configurable
    • Configurable contacts (switch on / switch off points, hysteresis / window mode, switch on / switch off delay)
    Optional Features
    • IS-version : Ex ia = intrinsically safe for gases
    • Customer specific versions
    • Analogue output
    Areas of Application
    • Medical Technology
    • Food and Beverage
  • Features
    • Nominal pressure: 0 ... 400 mbar up to 0 ... 600 bar
    • Accuracy: 0.5 % FSO
    • Indication of measured values on a 4-digit LED display
    • Rotatable and configurable display module
    • 1, 2 or 4 independent PNP contacts, freely configurable
    Optional Features
    • IS-version: Ex ia = intrinsically safe for gases
    • Pressure port PVDF
    • Customer specific versions
    Areas of Application
    • Mechanical and Plant Engineering
    • Environmental Industry
  • Features
    • Nominal pressure: 0 ... 60 bar up to 0 ... 400 bar
    • Accuracy: 0.5 % FSO
    • 1, 2 or 4 independent PNP contacts, freely configurable
    • Rotatable and configurable display module
    • Indication of measured values on a 4-digit LED display
    Optional Features
    • IS-version - Ex ia = intrinsically safe for gases
    • Cooling element up to 300°C
    • Customer specific versions
    Areas of Application
    • Mechanical and Plant Engineering
    • Food and Beverage
  • Features
    • Nominal pressure: 0 ... 6 bar up to 0 ... 600 bar
    • Accuracy: 0.5 % FSO
    • Indication of measured values on a 4-digit LED display
    • Rotatable and configurable display module
    • 1, 2 or 4 independent PNP contacts, freely configurable
    Optional Features
    • IS-version: Ex ia = intrinsically safe for gases
    • Oxygen application
    • Customer specific versions
    Areas of Application
    • Mechanical and Plant engineering
    • Energy Industry
    • Refrigeration Engineering
    • Medical Technology
    • Utility Vehicles / Mobile Hydraulics
  • Features
    • Nominal pressure: 0 ... 10 mbar up to 0 ... 1000 mbar
    • Accuracy: 0.35 % FSO
    • Indication of measured values on a 4-digit LED display
    • Rotatable and configurable display module
    • 1, 2 or 4 independent PNP contacts, freely configurable
    Optional Features
    • IS-version: Ex ia = intrinsically safe for gases
    • Customer specific versions
    Areas of Application
    • Mechanical and Plant Engineering
    • HVAC
    • Laboratory
  • Features
    • Nominal pressure: 0 ... 600 bar up to 0 ... 2200 bar
    • Accuracy: 0,35 % FSO
    • Indication of measured values on a 4-digit LED display
    • Rotatable and configurable display module
    • 1, 2 or 4 independent PNP contacts, freely configurable
    • Pressure sensor welded
    • Extremely robust and excellent longterm stability
    Optional Features
    • Adjustability of span and offset (4 ... 20 mA / 3-wire)
    • Customer specific versions
    Areas of Application
    • Mechanical and Plant Engineering
    • Utility Vehicles / Mobile Hydraulics
  • Features
    • Nominal pressure: 0 ... 6 bar up to 0 ... 600 bar
    • Accuracy: 0.5 % FSO
    • 1 analog output and up to 2 contacts
    • Display and housing rotatable
    • Perfect for oxygen applications
    Areas of Application
    • Mechanical and Plant Engineering
    • Energy Industry
    • Refrigeration Engineering
    • Medical Technology
    • Utility Vehicles / Mobile Hydraulics
  • Features
    • Nominal pressure: 0 ... 2 bar up to 0 ... 400 bar
    • Accuracy: 1.5 % FSO
    • Display and housing rotatable
    • Up to 2 contacts
    • Configurable via display
    Optional Features
    • Analog output
    Areas of Application
    • Mechanical and Plant Engineering
    • Energy Industry
  • Features
    • Nominal pressure: 0 ... 6 mbar up to 0 ... 1000 mbar
    • Accuracy: 0,35 % FSO
    • Aluminum housing
    • Rotatable and configurable display module
    • 4-digit LED display
    • Suited for non-aggressive gases and compressed air
    Optional Features
    • 1 / 2 PNP contacts
    • customer specific versions
    Areas of Application
    • Mechanical and plant engineering
    • HVAC
  • Features
    • Nominal pressure: 0 ... 100 mbar up to 0 ... 600 bar
    • Accuracy: 0,35 % FSO
    • Analog output (optional): 4 ... 20 mA or 0 ... 10 V
    • Indication of measured values on a 4-digit LED display
    • Parametrization by IO-Link or set menu system (VDMA-conform)
    • Rotatable and configurable display
    • 2 contacts
    Optional Features
    • different mechanical connections
    • customer specific versions
    Areas of Application
    • Mechanical and Plant Engineering
    • Hydraulics
    • Packaging and Paper Industry
     
  • Characteristics
    • nominal pressure ranges from 0 ... 1 bar up to 0 ... 10 bar also -1 ... 0 bar
    •  1 or 2 contacts
    • Compact design
    • Configurable via PC or programming device P6
    Applications
    • Pneumatic
    • Vacuum technology
  • Features
    • Nominal pressure: 0 ... 100 mbar up to 0 ... 600 bar
    • Accuracy: 0.35 % (opt. 0.25 %) FSO
    • Indication of measured values on a 4-digit LED display
    • Rotatable and configurable display module
    • 1 or 2 independent PNP contacts, freely configurable
    Optional Features
    • IS-version - Ex ia = intrinsically safe for gases and dust
    • Pressure sensor welded
    • Customer Specific Versions
    Areas of Application
    •  Mechanical and plant engineering
    •  HVAC
    • Environmental industry
  • Features
    • Nominal pressure: 0 ... 100 mbar up to 0 ... 40 bar
    • Accuracy: 0.35 % (opt. 0.25 %) FSO
    • 1 or 2 independent PNP contacts, freely configurable
    • Indication of measured values on a 4-digit LED display
    • Rotatable and configurable display module
    • Hygienic process connections with flush stainless steel diaphragm
    • Configurable contacts (switch on / switch off points, hysteresis / window mode, switch on / switch off delay)
    Optional Features
    • IS-version - Ex ia = intrinsically safe for gases
    • Analog Output - 2-wire: 4 ... 20 mA, 3-wire: 4 ... 20 mA with Turn Down 1:5, 0 ... 10
    • Customer Specific Versions
    Areas of Application
    • Medical Technology
    • Food and Beverage
  • Features
    • nominal pressure: 0 ... 400 mbar up to 0 ... 600 bar
    • accuracy: 0.5 % FSO
    • rotatable and configurable display module
    • indication of measured values on a 4-digit LED display
    • 1 or 2 independent PNP contacts, freely configurable
     Optional Features
    • IS-version Ex ia = itrinsically safe for gases
    • pressure port PVDF
    • customer specific versions
    Areas of Application
    • Mechanical and plant engineering mechanical and plant engineering
    • Environmental industry environmental industry
     
  • Features
    • Nominal pressure: 0 ... 2 bar up to 0 ... 400 bar
    • Accuracy: 1 % FSO
    • 1 or 2 contacts
    • Configurable via PC or programming device P6
    • Diaphragm ceramic (96 %)
    Optional Features
    • Oil- and grease free application
    Areas of Application
    • Mechanical and plant engineering
    • Energy Industry

Title