Temperature

  • Features
    • measurement range -40 to +125°C (-40 to +257°F)
    • Stores over 250,000 readings
    • Logging rates between 2 seconds and 1 hour
    • On screen menu and graphing to start, stop, review and restart the logger in the field
    • Triggered logging mode to start recording data once a user defined level is met
    • User-programmable audible alarm thresholds with highly visible confidence/alarm LEDs
     
  • Features
    • -30 to 80°C (-22 to +176°F) measurement range
    • Stores over 250,000 readings
    • Logging rates between 10 seconds and 1 hour
    • On screen menu and graphing to start, stop, review and restart the logger in the field
    • Triggered logging mode to start recording data once a user defined level is met
    • User-programmable audible alarm thresholds with highly visible confidence/alarm LEDs
     
  • Features
    • 3 data loggers for monitoring Chilled Goods, Frozen Goods and Ripening Goods
    • No set-up required. One button press-to-start logging
    • Pre-configured with appropriate sample rates and alarm thresholds for each application
    • Reusable with 12+ months battery life
    • Various export options including PDF, Microsoft Excel and JPEG
     
  • Features
    • Compatible with K, J and T-type with miniature thermocouple plug connection
    • Stores over 250,000 readings
    • EasyLog software available as a free download
    • Logging rates between 2 seconds and 1 hour
    • Supplied with 1.5m K-type thermocouple with 0 to 200°C (32 to 392°F)
    • Immediate, delayed, push-button or temperature triggered start mode
     
  • Features
    • 3 data loggers for monitoring Chilled Goods, Frozen Goods and Ripening Goods
    • No set-up required. One button press-to-start logging
    • Pre-configured with appropriate sample rates and alarm thresholds for each application
    • Reusable with 12+ months battery life
    • Various export options including PDF, Microsoft Excel and JPEG
     
  • Features
    • 3 data loggers for monitoring Chilled Goods, Frozen Goods and Ripening Goods
    • No set-up required. One button press-to-start logging
    • Pre-configured with appropriate sample rates and alarm thresholds for each application
    • Reusable with 12+ months battery life
    • Various export options including PDF, Microsoft Excel and JPEG
     
  • Features
    • -40 to +125°C (-40 to +257°F) measurement range
    • Stores over 32,000 readings
    • EasyLog software available as a free download
    • Logging rates between 1 second and 12 hour
    • Immediate, delayed and push-to-start logging
    • User-programmable alarm thresholds
     
  • Features
    • -40 to +125°C (-40 to +257°F) measurement range
    • Stores over 32,000 readings
    • EasyLog software available as a free download
    • Logging rates between 1 second and 12 hour
    • Immediate, delayed and push-to-start logging
    • User-programmable alarm thresholds
     
  • Features
    • Compatible with K, J and T-tyoe thermocouple with miniature thermocouple plug connection
    • Stores over 32,000 readings
    • Logging rates between 1 second and 12 hours
    • Immediate and delayed logging start
    • EasyLog software available as a free download
    • Supplied with 1.5m K-type thermocouple probe with 0 to 200°C (32 to 392°F) measurement range
     
  • Features
    • Compatible with K, J and T-type thermocouple with miniature thermocouple plug connection
    • Stores over 32,000 readings
    • Logging rates between 1 second and 12 hours
    • Immediate and delayed logging start
    • EasyLog software available as a free download
    • Supplied with 1.5m K-type thermocouple probe with 0 to 200°C (32 to 392°F) measurement range
     
  • Features
    • -20 to +60°C (-4 to +140°F) measurement range
    • Stores over 32,000 readings
    • EasyLog software available as a free download
    • Logging rates between 2 seconds and 1 hour
    • Immediate and delayed logging start
    • User-programmable alarm thresholds
    • Stainless steel (316 grade) case
  • Features
    • -10 to +50°C (-14 to +122°F) measurement range
    • Stores over 4,000 readings
    • EasyLog software available as a free download
    • 30 minutes logging rate
    • Immediate and delayed logging start
    • User-programmable alarm thresholds
     
  • Features
    • -35 to +80°C (-31 to +176°F) measurement range
    • Stores over 16,000 readings
    • EasyLog software available as a free download
    • Logging rates between 2 seconds and 1 hour
    • Immediate and delayed logging start
    • User-programmable alarm thresholds
    • Status indication via red/green and amber LEDs
     
  • Features
    • -40 to +125°C (-40 to +257°F) measurement range
    • Stores over 32,000 readings
    • EasyLog software available as a free download
    • Logging rates between 2 seconds and 1 hour
    • Immediate and delayed logging start
    • User-programmable alarm thresholds
    • Stainless steel (316 grade) case
     
  • Features
    • -35 to +80°C (-31 to +176°F) measurement range
    • Stores over 16,000 readings
    • EasyLog software available as a free download
    • Logging rates between 2 seconds and 1 hour
    • Immediate and delayed logging start
    • User-programmable alarm thresholds
    • Status indication via red/green and amber LEDs
     
  • Main Function
    • Output controllable based on measured pressure value (increase and decrease)
    • Alternative operation available between freezing exclusive model and booster
    • Pump unit control model
    • RS485 MODBUS
     
  • Main Function
    • 3 stage fan speed controllable
    • 4 kind (stop / high / middle / low) airflow choosable
    • Unification of temperature control function
    • Data backup
    • Self diagnostic
    • RS485 communication (MODBUS)
     
  • Main Function
    • Embedded run/stop switch, motor on/off, load run, auto-stop, manual stop, operation delay, load delay, embedded timer
    • Pressure / temperature high level
    • Temperature low level (standby for starting)
    • Interlock input signal (emergency switch, OCR reverse phase)
    • Usable thermometer and manometer
    • RS485 communication (MODBUS)
     
  • Main Function
    • Embedded run/stop switch, motor on/off, load run, auto-stop, manual stop, operation delay, load delay, embedded timer
    • Pressure / temperature high level
    • Temperature low level (standby for starting)
    • Interlock input signal (emergency switch, OCR reverse phase)
    • Usable thermometer and manometer
    • RS485 communication (MODBUS)
     
  • Main Function
    • Defrosting (auto / manual)
    • Defrosting stop delay
    • 2 air inlet/outlet sensors
    • One sensor for defrost recovery
    • High / Low alarm output
    • Indicator (FixView) connection
    • RS485 communication (MODBUS)
     
  • Main Function
    • Defrosting (auto / manual)
    • Defrosting stop delay
    • Evaporation fan control
    • Air inlet/outlet sensor: 2EA
    • Defrost recovery sensor: 1EA
    • Virtual temperature sensor computing
    • Door open alarm
    • Emergency call
    • Night operation
    • High (low) temperature alarm output
    • RS485 communication (MODBUS)
     
  • Main Function
    • Uniform step control
    • Operation with intelligent shift high / low alarm output
    • Sensor correction / Sensor error detection
    • Transmission output
    • RS485 communication (MODBUS)
     
  • Main Function
    • Efficient defrosting in geothermy heat pump system
    • Defrosting execution by measuring of ambient humidity and temperature
     
  • Main Function
    • Defrosting (auto / manual)
    • Fan control
    • Efficient delay
    • Room temperature sensor: 1EA
    • Defrost sensor: 1EA
    • High (low) temperature alarm output
    • Room temperature transmission output (4~20 mA)
    • RS485 communication (MODBUS)
     
  • Main Function
    • PID degree of superheat control through defense and safety compensation
    • Degree of superheat control for various refrigerant
    • PMW (opening ratios control)
    • Remote operation
    • Transmission output
    • RS485 communication (MODBUS)
     
  • Main Function
    • Total control and detection (protection) for freezers
    • Function of start, restart, pump down, alarm delay timer
    • Discharge gas detection (high & low temperature)
    • Individual alarm message (OC, HP, LP, OP, INT)
    • RS485 communication (MODBUS)
     
  • Main Function
    • Heating / cooling output
    • Independent timer output
    • High / Low alarm output
    • Precise temperature control
    • Sensor correction
    • Sensor error detection
    • Data back up
    • Minimum on/off maintaining time setup
    • RS485 communication (MODBUS)
    • Transmission output
     
  • Main Function
    • Heating/cooling output
    • High / Low alarm output
    • Precise temperature control.
    • Sensor correction, sensor error detection
    • Sensor error detection
    • Data backup
    • Min. on/off maintaining time setup
    • Transmission output
    • RS485 communication (MODBUS)
  • Main Function
    • Heating / cooling output
    • Precise temperature control
    • Sensor correction
    • Sensor error detection
    • Data back up
    • Minimum on/off maintaining time setup
    • Auto-output operation cycle settable in case of sensor error
     
  • Main Function
    • Heating / cooling output
    • High / Low alarm output
    • Precise temperature control
    • Sensor correction
    • Sensor error detection
    • Data back up
    • Minimum on/off maintaining time setup
    • RS485 communication (MODBUS)
    • Transmission output
     
  • Main Function
    • Heating / cooling output
    • Independent timer output
    • High / Low alarm output
    • Defrost output
    • Precise temperature control
    • Sensor correction
    • Sensor error detection
    • Data back up
    • Minimum on/off maintaining time setup
    • RS485 communication (MODBUS)
    • Transmission output
    • Auto-output operation cycle settable in case of sensor error
  • Main Function
    • Heating / cooling output
    • Independent timer output
    • High / Low alarm output
    • Defrost output
    • Precise temperature control
    • Sensor correction
    • Sensor error detection
    • Data back up
    • Minimum on/off maintaining time setup
    • RS485 communication (MODBUS)
    • Transmission output
    • Auto-output operation cycle settable in case of sensor error
     
    • Lightweight, compact, 2-in-1 design
    • Thermocouple probe for internal product temperature
    • Infrared for instant non-contact surface measurement
    • Multi-beam laser for accurate targeting
    • Ideal for extremely hot areas, moving objects, hard to reach places
    • Green backlight indicates HACCP food safety zone
    • Red backlight indicates HACCP danger zone
    • Min/Max memory in IR mode
    • NSF Certified, NIST traceable
    • Fast 3 second thermocouple reading
    • Instant infrared reading
    • Low battery indicator
  • Features
    • IP66 Water-Proof
    • Accept 9 T/C Types
    • Dual Probes (T1-T2)
    • Data-Logger Built-In
    • USB/RS-232 Output, with Software
    • Fine Adjustment Function
    • Hi/Lo Alarm
    • Max./Min./Avg./Hold
    • LED Back-Light
    • CE and RoHS Approved
  • Features
    • K.J.E.T.N.R.S.B Eight Types Available
    • Concise Buttons and Operation Interface
    • Carry Out Simple and Durable Principles
    • Very Practical and Low Prices
    • Fast Response and High Accuracy
    • RS-232 Signal Output
    • CE and RoHS Approved
  • Feature
    • High Resolution : 0.01°
    • IP66 Water-Proof
    • Accept PT100 and PT1000Ω Input
    • Dual Probes (T1-T2)
    • Large LCD Display with LED Back-Light
    • Hold / Max. / Min. / Average
    • High / Low Alarm Setting
    • USB / RS-232 Output
    • CE and RoHS Approved
Go to Top