Loading...
  • Features
    • Accuracy to 0.01% of reading
    • Small and rugged handheld design
    • Measure, source, or simulate loop current
    • Measure DC volts
    • Simultaneously mA and % span display
    • Switch functionality
    • Selectable ramp and step functions
    • Easy to read display and user interface
    • HART 250Ω resistor in series with 24V loop
  • Features
    • Portable, only 5.7 lb
    • Great stability and high resolution
    • Minimal maintenance
    • Hand-tight quick connectors
    Application The Additel 918 is designed to generate pressure from 95% vacuum to 1,500 psi (100 bar) for the application requiring accurate pressure testing and calibration. It can be used in calibrating large size pressure gauges, transmitters, or other pressure measuring instruments.
  • Features
    • Generate 3,000 psi (200 bar) in 40 seconds
    • Minimal maintenance
    • Hand-tight quick connectors
    • First one in the world
    Application The Additel 920 and 920HV are designed to generate pressure from 95% vacuum to 3,000 psi (200 bar) for the high pressure application requiring accurate pressure testing and calibration. It can be used in calibrating high pressure gauges, transmitters, or other pressure measuring instruments.
  • Features
    • Portable, only 3.3 lb
    • Great stability and high resolution
    • Minimal maintenance
    • Hand-tight quick connectors
    Applications The Additel 914A Pneumatic Pressure Test Pump is designed to generate pressure from 95% vacuum to 375 psi (25 bar) for the application requiring accurate pressure testing and calibration. It can be used in calibrating pressure gauges, transmitters, or other pressure measuring instruments.
  • Features
    • Portable, only 5.9 lb
    • Great stability and high resolution
    • Minimal maintenance
    • Hand-tight quick connectors
    Applications The Additel 916A is designed to generate pressure from 95% vacuum to 600 psi (40 bar) for the application requiring accurate pressure testing and calibration. It can be used in calibrating large size pressure gauges, transmitters, or other pressure measuring instruments.
  • Features
    • Portable, only 5.7 lb
    • Great stability and high resolution
    • Minimal maintenance
    • Hand-tight quick connectors
    Applications The Additel 917 is designed to generate pressure from 95% vacuum to 1,000 psi (70 bar) for the application requiring accurate pressure testing and calibration. It can be used in calibrating large size pressure gauges, transmitters, or other pressure measuring instruments.
  • Features
    • Generate 2000 psi (140 bar) in 30 seconds
    • Minimal maintenance
    • Hand-tight quick connectors
    • First one in the world
    Applications The Additel 919A is designed to generate pressure from 95% vacuum to 2000 psi (140 bar) for the high pressure application requiring accurate pressure testing and calibration. It can be used in calibrating high pressure gauges, transmitters, or other pressure measuring instruments.
  • Features • Portable, only 7 lb • Minimal maintenance • Increase and decrease pressure smoothly • Hand-tight quick connectors Applications The Additel 927 is designed to generate pressure from 85% vacuum to 10,000 psi (700 bar) for the application requiring accurate pressure testing and calibration. It can be used in calibrating pressure gauges, transmitters, or other pressure measuring instruments.
  • Features • Compatible to phosphoric acid ester fluid and Skydrol Oil • Increase and decrease pressure smoothly • Three pressure ports • Hand-tight quick connectors Applications The Additel 937 is designed to generate pressure from 85% vacuum to 15,000 psi (1000 bar) for the application requiring accurate pressure testing and calibration. It can be used in calibrating pressure gauges, transmitters, or other pressure measuring instruments.
  • Features
    • Pressurize large-volume workload
    • Generate pressure to 15,000 psi (1,000 bar)
    • Increase and decrease pressure smoothly
    • Three pressure ports
    • Hand-tight quick connectors
    Applications The Additel 946A is designed to generate pressure to 15,000 psi (1000 bar) for the application requiring accurate pressure testing and calibration. It can be used in calibrating pressure gauges, transmitters, or other pressure measuring instruments.
  • Features
    • Pressurize large-volume workload
    • Generate pressure to 40,000 psi (2,800 bar) pressure
    • Increase and decrease pressure smoothly
    • Three pressure ports
    Applications The Additel 959A is designed to generate pressure up to 40,000 psi (2,800 bar) for the application requiring accurate pressure testing and calibration. It can be used in calibrating pressure gauges, transmitters, or other pressure measuring instruments.
  • Features • 1/4NPT male to various connectors as follows (Designed for all pumps except Additel 949 ,959,960 pumps)
  • ADT103-NPT Adapter and Fitting, 1/4" NPT male to various female hand-tight quick connectors (10 pc). ADT103-BSP Adapter and Fitting, 1/4"BSP male to various female hand-tight quick connectors (10 pc). ADT103-M20 Adapter and Fitting, M20X1.5 male to various female hand-tight quick connectors (10 pc). (Designed for all pumps except Additel 949 pump)
  • ADT104-HP 1/4HP male (Autoclave M-250-C) to various connectors as follows (17 pc, case included): (Designed for Additel 949, 959, and 960 pumps)
  • Features
    • °F/°C selectable
    • Min/Max memory stores lowest/highest readings
    • Automatic calibration feature
    • IP65 Waterproof
    • Reduced Tip Probe
    • Complies with FDA Food Code 4-203.11
  • Features
    • NSF certified
    • °F/°C selectable
    • Min/Max memory stores lowest/highest readings
    • Automatic calibration feature
    • IP65 Waterproof housing
    • Small-diameter probe ideal for measuring temperature of "thin mass" food such as meat patties and chicken/fish fillets (FDA Food Code 4-302.12 (B).
  • Features
    • Dual Input
    • Dual Display
    • Auto Powe Off
    • RS-232 Interface
    • REL Function
    • HOLD Function
    • MAX AVG MIN Function
    • Resolution 0.1°C 0.1°F
    • Low Battery Indication
  • Features
    • Dual Input
    • Triple Display
    • Time Function
    • RS-232 Interface
    • With Window Software
    • 16,000 Records Data logger
    • Auto Power Off
    • REL Function
    • MAX MIN Function
    • Resolution 0.1°C 0.1°F
    • Low Battery Indication
  • Features
    • Auto Range
    • PC Interface
    • LED Backlight
    • HOLD Function
    • Four Channel Input
    • Four Channel Display
    • Resolution 0.1°C 0.1°F
    • With Windows Software
    • MAX MIN Function
    • Auto Shut Off for battery saving
    • 16,000 Records Data logger each channel
  • Features
    • Measuring Range : -200 to +1772°C
    • High Accuracy and Fast Response
    • Digital LCD Display with Back-Light
    • Records Max./Min. Values
    • RS-232 Signal Output
    • CE and ROHS Approved
  • Features
    • High Resolution 0.01 (-200.00 ~ + 1372.00°C)
    • Dual Type K (CA) input
    • P66 Water-Proof
    • USB / RS-232 Output
    • High / Low Alarm
    • T1-T2 / Max. / Min. / Avg.
    • Large Display LED Back-Light
  • Feature
    • High Resolution : 0.01°
    • IP66 Water-Proof
    • Accept PT100 and PT1000Ω Input
    • Dual Probes (T1-T2)
    • Large LCD Display with LED Back-Light
    • Hold / Max. / Min. / Average
    • High / Low Alarm Setting
    • USB / RS-232 Output
    • CE and RoHS Approved
  • Features
    • K.J.E.T.N.R.S.B Eight Types Available
    • Concise Buttons and Operation Interface
    • Carry Out Simple and Durable Principles
    • Very Practical and Low Prices
    • Fast Response and High Accuracy
    • RS-232 Signal Output
    • CE and RoHS Approved
  • Features
    • IP66 Water-Proof
    • Accept 9 T/C Types
    • Dual Probes (T1-T2)
    • Data-Logger Built-In
    • USB/RS-232 Output, with Software
    • Fine Adjustment Function
    • Hi/Lo Alarm
    • Max./Min./Avg./Hold
    • LED Back-Light
    • CE and RoHS Approved
    • Lightweight, compact, 2-in-1 design
    • Thermocouple probe for internal product temperature
    • Infrared for instant non-contact surface measurement
    • Multi-beam laser for accurate targeting
    • Ideal for extremely hot areas, moving objects, hard to reach places
    • Green backlight indicates HACCP food safety zone
    • Red backlight indicates HACCP danger zone
    • Min/Max memory in IR mode
    • NSF Certified, NIST traceable
    • Fast 3 second thermocouple reading
    • Instant infrared reading
    • Low battery indicator
  • Main Function
    • Heating / cooling output
    • Independent timer output
    • High / Low alarm output
    • Defrost output
    • Precise temperature control
    • Sensor correction
    • Sensor error detection
    • Data back up
    • Minimum on/off maintaining time setup
    • RS485 communication (MODBUS)
    • Transmission output
    • Auto-output operation cycle settable in case of sensor error
     
  • Main Function
    • Heating / cooling output
    • Independent timer output
    • High / Low alarm output
    • Defrost output
    • Precise temperature control
    • Sensor correction
    • Sensor error detection
    • Data back up
    • Minimum on/off maintaining time setup
    • RS485 communication (MODBUS)
    • Transmission output
    • Auto-output operation cycle settable in case of sensor error
  • Main Function
    • Heating / cooling output
    • High / Low alarm output
    • Precise temperature control
    • Sensor correction
    • Sensor error detection
    • Data back up
    • Minimum on/off maintaining time setup
    • RS485 communication (MODBUS)
    • Transmission output
     
  • Main Function
    • Heating / cooling output
    • Precise temperature control
    • Sensor correction
    • Sensor error detection
    • Data back up
    • Minimum on/off maintaining time setup
    • Auto-output operation cycle settable in case of sensor error
     
  • Main Function
    • Heating/cooling output
    • High / Low alarm output
    • Precise temperature control.
    • Sensor correction, sensor error detection
    • Sensor error detection
    • Data backup
    • Min. on/off maintaining time setup
    • Transmission output
    • RS485 communication (MODBUS)
  • Main Function
    • Heating / cooling output
    • Independent timer output
    • High / Low alarm output
    • Precise temperature control
    • Sensor correction
    • Sensor error detection
    • Data back up
    • Minimum on/off maintaining time setup
    • RS485 communication (MODBUS)
    • Transmission output
     
  • Main Function
    • Total control and detection (protection) for freezers
    • Function of start, restart, pump down, alarm delay timer
    • Discharge gas detection (high & low temperature)
    • Individual alarm message (OC, HP, LP, OP, INT)
    • RS485 communication (MODBUS)
     
  • Main Function
    • PID degree of superheat control through defense and safety compensation
    • Degree of superheat control for various refrigerant
    • PMW (opening ratios control)
    • Remote operation
    • Transmission output
    • RS485 communication (MODBUS)
     
  • Main Function
    • Defrosting (auto / manual)
    • Fan control
    • Efficient delay
    • Room temperature sensor: 1EA
    • Defrost sensor: 1EA
    • High (low) temperature alarm output
    • Room temperature transmission output (4~20 mA)
    • RS485 communication (MODBUS)
     
  • Main Function
    • Efficient defrosting in geothermy heat pump system
    • Defrosting execution by measuring of ambient humidity and temperature
     
  • Main Function
    • Uniform step control
    • Operation with intelligent shift high / low alarm output
    • Sensor correction / Sensor error detection
    • Transmission output
    • RS485 communication (MODBUS)
     
  • Main Function
    • Defrosting (auto / manual)
    • Defrosting stop delay
    • Evaporation fan control
    • Air inlet/outlet sensor: 2EA
    • Defrost recovery sensor: 1EA
    • Virtual temperature sensor computing
    • Door open alarm
    • Emergency call
    • Night operation
    • High (low) temperature alarm output
    • RS485 communication (MODBUS)
     
  • Main Function
    • Defrosting (auto / manual)
    • Defrosting stop delay
    • 2 air inlet/outlet sensors
    • One sensor for defrost recovery
    • High / Low alarm output
    • Indicator (FixView) connection
    • RS485 communication (MODBUS)
     
  • Main Function
    • Embedded run/stop switch, motor on/off, load run, auto-stop, manual stop, operation delay, load delay, embedded timer
    • Pressure / temperature high level
    • Temperature low level (standby for starting)
    • Interlock input signal (emergency switch, OCR reverse phase)
    • Usable thermometer and manometer
    • RS485 communication (MODBUS)
     
  • Main Function
    • Embedded run/stop switch, motor on/off, load run, auto-stop, manual stop, operation delay, load delay, embedded timer
    • Pressure / temperature high level
    • Temperature low level (standby for starting)
    • Interlock input signal (emergency switch, OCR reverse phase)
    • Usable thermometer and manometer
    • RS485 communication (MODBUS)
     
  • Main Function
    • 3 stage fan speed controllable
    • 4 kind (stop / high / middle / low) airflow choosable
    • Unification of temperature control function
    • Data backup
    • Self diagnostic
    • RS485 communication (MODBUS)
     
  • Main Function
    • Output controllable based on measured pressure value (increase and decrease)
    • Alternative operation available between freezing exclusive model and booster
    • Pump unit control model
    • RS485 MODBUS
     
  • Features
    • -30 to 80°C (-22 to +176°F) measurement range
    • Stores over 250,000 readings
    • Logging rates between 10 seconds and 1 hour
    • On screen menu and graphing to start, stop, review and restart the logger in the field
    • Triggered logging mode to start recording data once a user defined level is met
    • User-programmable audible alarm thresholds with highly visible confidence/alarm LEDs
    • Environmental protection to IP67
  • Features
    • -30 to 80°C (-22 to +176°F) measurement range
    • Stores over 250,000 readings
    • Logging rates between 10 seconds and 1 hour
    • On screen menu and graphing to start, stop, review and restart the logger in the field
    • Triggered logging mode to start recording data once a user defined level is met
    • User-programmable audible alarm thresholds with highly visible confidence/alarm LEDs
    • Environmental protection to IP67
    • Higher accuracy sensor when compared with the EL-GFX-2
     
  • Features
    • -18 to +55°C (-0.4 to +131°F) temperature measurement range
    • 0 to 100%RH humidity measurement range
    • Stores over 1,000,000 readings (As per spec table)
    • No software to install - configure using your normal web browser
    • Use with a PC or Mac
    • Display shows current, maximum and minimum readings
    • Status and alarm indicators
    • Data can be uploaded to the EasyLog Cloud
  • Features
    • -18 to +55°C (-0.4 to +131°F) temperature measurement range
    • 0 to 100%RH humidity measurement range
    • Stores over 1,000,000 readings (As per spec table)
    • No software to install - configure using your normal web browser
    • Use with a PC or Mac
    • Display shows current, maximum and minimum readings
    • Status and alarm indicators
    • On-board alarm sounder
    • Data can be uploaded to the EasyLog Cloud
  • Features • -18 to +55°C (-0.4 to +131°F) temperature measurement range • 0 to 100%RH humidity measurement range • 300 to 1200mbar pressure measurement range • Stores over 1,000,000 readings (As per spec table) • No software to install - configure using your normal web browser • Use with a PC or Mac • Display shows current, maximum and minimum readings • Status and alarm indicators • On-board alarm sounder • Data can be uploaded to the EasyLog Cloud
  • Features
    • -35 to +80°C (-31 to +176°F) and 0 to 100%RH measurement range
    • Stores over 16,000 readings for both temperature and humidity
    • EasyLog software available as a free download
    • Logging rates between 10 seconds and 12 hour
    • Immediate and delayed logging start
    • User-programmable alarm thresholds for both temperature and humidity
    • Status indication via red/green LEDs
    • Environmental protection to IP67
     
  • Features
    • -35 to +80°C (-31 to +176°F) and 0 to 100%RH measurement range
    • Stores over 16,000 readings for both temperature and humidity
    • EasyLog software available as a free download
    • Logging rates between 10 seconds and 12 hour
    • Immediate and delayed logging start
    • User-programmable alarm thresholds for both temperature and humidity
     
  • Features
    • -35 to +80°C (-31 to +176°F) and 0 to 100%RH measurement range
    • Stores over 16,000 readings for both temperature and humidity
    • EasyLog software available as a free download
    • Logging rates between 10 seconds and 12 hour
    • Immediate and delayed logging start
    • User-programmable alarm thresholds for both temperature and humidity
     
  • Features
    • -35 to +80°C (-31 to +176°F) and 0 to 100%RH measurement range
    • Stores over 16,000 readings for both temperature and humidity
    • EasyLog software available as a free download
    • Logging rates between 10 seconds and 12 hour
    • Immediate and delayed logging start
    • User-programmable alarm thresholds for both temperature and humidity
    • Status indication via red/green LEDs
    • Environmental protection to IP67
     
  • Features
    • -10 to +60°C (-14 to +122°F) & 0 to 100%RH measurement range
    • Stores up to 7 days of data
    • Powered by USB
    • Real time logging
    • EasyLog RT software available as a free download
    • User-programmable alarm thresholds for temperature and humidity
       
  • Features
    • 20 to 60°C (-4 to +140°F) temperature and 0 to 100% humidity measurement range
    • Wirelessly stream and view data via WIFI on PCor FilesThruThaAir Cloud
    • Easy sensor set-up using free PC software application
    • View and analyze multiple sensors, including graphing of historic data
    • Configurable high and low alarms with indicator
    • Sensor memory stores all data even if WIFI is temporarily disconnected
     
  • Features
    • 20 to 60°C (-4 to +140°F) temperature and 0 to 100% humidity measurement range
    • Wirelessly stream and view data via WIFI on PCor FilesThruThaAir Cloud
    • Easy sensor set-up using free PC software application
    • View and analyze multiple sensors, including graphing of historic data
    • Configurable high and low alarms with indicator
    • Sensor memory stores all data even if WIFI is temporarily disconnected
     
  • Characteristics:
    • Stainless steel sensor, welded
    • Accuracy 0.5 % FSO according to IEC 60770
    • nominal pressure ranges from 0 … 6 bar up to 0 … 600 bar
  • Characteristics
    •  Stainless steel sensor, welded
    • Accuracy 0.5 % FSO according to IEC 60770
    • Nominal pressure ranges from 0 … 6 bar up to 0 … 60 bar and -1 … 6 bar up to -1 … 60 bar
  • Characteristics:
    • Stainless steel sensor, welded
    • Nominal pressure ranges from 0 … 16 bar up to 0 … 1000 bar
    • Accuracy according to IEC 60770: 0.5 % FSO
  • Characteristics
    • Silicon sensor without media isolation
    • Accuracy 0.5 % FSO according to IEC 60770
    • Nominal pressure ranges from 0 … 100 mbar up to 0 … 6 bar
  • Characteristics
    • Piezoresistive stainless steel sensor
    • Accuracy 0.5 % FSO according to IEC 60770
    • Nominal pressure ranges from 0 … 100 mbar up to 0 … 6 bar
  • Characteristics
    • Piezoresistive stainless steel sensor
    • Accuracy 0.5 % FSO according to IEC 60770
    • Nominal pressure ranges from 0 … 1 mH2O up to 0 … 10 mH2O
  • Characteristics
    • Ceramic sensor
    • Accuracy 0.5 % FSO according to IEC 60770
    • Nominal pressure ranges from 0 … 1 bar up to 0 … 400 bar
    • Option: oil and grease free version
  • Characteristics
    • Ceramic sensor
    • Accuracy 1 % FSO according to IEC 60770
    • Nominal pressure ranges from 0 … 1.6 bar up to 0 … 250 bar
  • Characteristics
    • Stainless Steel Sensor
    • Accuracy according to IEC 60770:
    • Standard: 0.25 % FSO
    • Option: 0.1 % FSO
  • Characteristics
    • Stainless Steel Sensor
    • Accuracy according to IEC 60770:
    • Standard: ≤ ± 0.35 % FSO
    • Option: ≤ ± 0.25 % FSO
  • Characteristics
    • Stainless Steel Sensor
    • Accuracy according to IEC 60770: standard: ≤ ± 0.35 % FSO option: ≤ ± 0.25 % FSO
  • Characteristics
    • Ceramic Sensor
    • Accuracy according to IEC 60770: 0.5 % FSO
  • Characteristics
    • Ceramic Sensor
    • Accuracy according to IEC 60770: 0.5 % FSO
  • Characteristics
    • Ceramic Sensor
    • Accuracy according to IEC 60770: 0.5 % FSO
  • Characteristics
    • Pressure Ports with Flush Welded Stainless Steel Diaphragm
    • Accuracy according to IEC 60770: 0.5 % FSO
  • Characteristics
    • Nominal pressure  from 0...40 mbar Up To 20 Bar
    • Ceramic Sensor, Flush, Hygienical Application
    • Accuracy according to IEC 60770: Standard: 0.35 % FSO Option: 0.25 % FSO
  • Characteristics
    • Ceramic Sensor, Marine, Shipbuilding, Offshore,
    • Nominal pressure  range from 0...400 mbar Up To 600 Bar
    • Accuracy according to IEC 60770: 0.5 % FSO
     
  • Characteristics
    • Ceramic Sensor
    • Accuracy according to IEC 60770: Standard: 0.25 % FSO Option: 0.1 % FSO
Go to Top