Skip to content
Features
New & improved petroleum resistant scale, makes it easier to read.
Choose 10 liter capacity fuel test measure cans.
Provides a calibrated measure for testing the accuracy of fuel dispensing equipment.
Stainless steel construction.
Suitable for use with diesel proving can, biodiesel, petrol & AdBlue
304 stainless steel construction.
Filling the measure to the “zero” mark will ensure an accurate amount of liters has been dispensed allowing the dispenser to be calibrated accordingly
Full range of spares available on request
Features
Automated pressure generation and control to 10,000 psi (700 Bar)
Accuracy to 0.01%FS
Dual-range with a manual or auto-selected mode
Designed for use with deionized water
Control stability ≤ 0.005%FS
Portable - designed for use in the field and in the lab
Supports two external pressure modules
Wi-Fi, LAN, Bluetooth, USB and Ethernet communication
Full HART field communicator
HART and profibus communication
Data logging and task management
Patented electric pump technology
ISO 17025-accredited calibration w/data included
Features
Maximum pressure control range to 15,000 psi (1,000 Bar)
Interchangeable pressure module
Oil and water versions available
Accuracy of 0.02%FS, 0.01%FS or 0.01%RD
Dual-range from -15~3,000 psi (-1~200 Bar ) to 0~15,000 psi (0~1,000) Bar
Control stability 0.005%FS
Ultra-High speed pressure generation and control
No external pressure source required
Control using internal or external pressure modules
Contamination Prevention System (CPS) (ADT793 optional)
LAN, USB, RS232, and Ethernet communication
External reservoir support
Easy maintenance
Emulation mode
Features
Pressure ranges from -14.35 psi (-0.99 bar) to 3600 psi (250 bar)
Two removable internal pressure modules with multi-range selection
0.02% FS, 0.01% FS, and 0.011% RD accuracies available
Control stability of 0.003%FS
Ultra-High speed pressure control
Absolute and Gauge Pressure
WiFi enabled communications
Large 7" color touch screen display
Optional barometer module
Easy-to-use icon driven interface
I/O alarm
Features
Pressure ranges from -380 inH2O (-0.95 bar) to 400 inH2O (1 bar)
Two removable internal pressure modules
0.02%FS accuracy
Control stability of 0.003%FS
Ultra-High speed pressure generation and control
Optional barometric pressure module
Built-in differential pressure pump
Large 7" color touch screen display
Multi-automatic test functions:pressure switch, test, leak test, PSV test, etc.
Modular design for easy maintenance, greatly reducing on-site downtime
Features
Resolution 0.001 ° C, accuracy of 0.01
Highly intelligent and easy to operate
AC Power abrupt change feedback
Features
Electric pump for one handed pressure calibration
Best in class pressure measurement uncertainty of 0.025 %
Measure and source mA with best in class 0.015 % accuracy
Precision pressure adjust vernier
Variable release rate bleed valve for easy pressure adjustment
Ideal performance for high accuracy transmitter calibration
30 PSI and 100 PSI pressure ranges
Programmable pump limit:
- Eliminates over-pressurization
- Allows the user to program target pressures for pumping
Extended measurement range with any of twenty-nine (29)
700Pxx Pressure Modules
Source mA with simultaneous pressure measurement to
test valves and I/Ps
Simulate mA signals to troubleshoot 4-20 mA loops
Test pressure switches with built in switch test function
Power transmitters during test using 24 V loop supply
Proven cleanout ports reduce pump failures
Features
PTB330 digital barometer for accurate pressure measurement
Handheld MI70 indicator with a user-friendly, multilingual display
Service port for MI70 Link software or computer
Vaisala HUMICAPâ humidity and temperature probe HMP155
Weatherproof transport case
Features
Dew point range -20℃ to +85℃
Accuracy to ±0.20 ℃ dew point
Dynamic balance control for contamination
Simultaneously measures dew point, temperature, relative humidity, absolute humidity, specific humidity, enthalpy, vapor pressure and volume ratio (ppmV).
Real time data logging and curve display
MAX value and MIN value are recorded
AC or alternative DC power supply
MODBUS RTU and USB communication
4 inch touch screen
Features
Dew point measure range -40℃to +90℃
Accuracy to ±0.15 ℃ dew point
Dynamic balance control for contamination
Simultaneously measures dew point, temperature, relative humidity, absolute humidity, specific humidity, enthalpy, vapor pressure and volume ratio (ppmV).
Real time data logging and display curve
MAX value and MIN value are recorded
AC or alternative DC power supply
MODBUS RTU and USB communication
4 Inch touch screen
External temperature sensor port
Improved frost assurance at low dew points
Features
0.02%, 0.05% FS Accuracy
Intrinsically Safe
Field Switchable Pressure Module
Dual Digital Pressure Module Inputs
Color Touchscreen Display
Built-in Quick Test Task Feature
Built-in Barometer
Intuitive Smartphone Like Interface
Bluetooth and USB Communication
Optional HART Communication
Communicates with Additel's Link Mobile App
Features
Sourcing, simulating and measuring pressure, temperature and electrical signals
Built-in Full Hart Communicator (ADT227-HART)
Built-in Barometer
Intrinsically safe models available (Ex)
Large Smartphone Like Touchscreen User Experience
USB Type-C and Bluetooth communications
IP67 Rated
High Voltage Measurement Capability (±300V AC)
True RMS Voltage Meter Capability
Dual channel pressure module ports
High Static Differential Pressure Measurement 0.002% FS
ISO 17025-accredited calibration w/data included
Features
Pressure ranges up to 60,000 psi (4,200 bar)
0.02%, 0.05% FS or 0.1% RD Accuracy
Color Touchscreen Display
Every model measures Gauge or Absolute Pressure
Built-in Barometer
Intuitive Smartphone Like Interface
Bluetooth and USB Communication
Wi-Fi (optional)
Measure mA or V, and with 24V loop power
Full HART Field Communicator (Optional)
Data logging
Communicates with Additel's Link Mobile App
ISO 17025-accredited calibration w/data included
Features
Pressure ranges up to 60,000 psi (4,200 bar)
0.02%, 0.05% FS or 0.1% RD Accuracy
Color Touchscreen Display
Every model measures Gauge or Absolute Pressure
Built-in Barometer
Intuitive Smartphone Like Interface
Wi-Fi (optional)
Bluetooth and USB communication
Data logging (optional)
Communicates with Additel's Link Mobile App
IP67 Rated
ISO 17025-accredited calibration w/data included
Features
Sourcing, simulating and measuring pressure, temperature and electrical signals
Built-in Full Hart Communicator (ADT227-HART)
Built-in Barometer
Intrinsically safe models available (Ex)
Large Smartphone Like Touchscreen User Experience
USB Type-C and Bluetooth communications
IP67 Rated
High Voltage Measurement Capability (±300V AC)
True RMS Voltage Meter Capability
Dual channel pressure module ports
High Static Differential Pressure Measurement 0.002% FS
ISO 17025-accredited calibration w/data included
Features
Sourcing, simulating and measuring pressure, temperature and electrical signals
Built-in Barometer
Intrinsically safe models available (Ex)
Large Smartphone like touchscreen user experience
USB Type-C and Bluetooth communications
IP67 Rated
High Voltage Measurement Capability (±300V AC)
True RMS Voltage Meter Capability
Dual channel pressure module ports
High Static Differential Pressure Measurement 0.002% FS
ISO 17025-accredited calibration w/data included
Features
Automated and self-contained pressure generation and control to 1000 psi ( 69 bar) or 1200 hPa
Standard accuracy models to 0.02%FS
Two removable internal pressure modules for multi-range selection (Single pressure module for barometric)
Control stability to 0.003%FS or 0.02 hPa
Portable, designed for use in the field and in the lab
Ability to measure two external pressure modules
Wi-Fi, Bluetooth, USB and Ethernet communication
HART and profibus communication
Data logging and task management
Patented electric pump technology and improved speed
ISO 17025-accredited calibration w/data included
Features
Uses a multi-fin, centrifugal level vertical heat exchange circulation system; ventilation rate can be adjusted to the desired rate.
Internal rotating pan can be convenient removed and installed, the motor rotating speed of hang shelf is 8-10 rpm.
A digital watt/hour meter and timer can be used to present the air refresh rate.
Features
Panel Dimension: 1.5" - 3.4"; 14.1" - 42"
CLCD-9700 Color touch panel controller was made in Japan
Forced air in and out to control the loading of specimen
Wider viewing glass design and have a connecting to safety protection device
Easily changed design as your product changes
Features
2-Zone/ 3-Zone Stationary Specimen, Exposure By Cooling Air/ Hot Air Changeover.
The machine is divide into three sections: the high temperature chamber, the low temperature chamber and the testing chamber.
The color touch panel control system was made in Japan can display Chinese / English. The big size liquid-crystal LCD (320X240) has been adopted.
High formula memory capacity may be set to 100 patterns. the maximum cycle setting is 9999 cycles. The maximum setting of each section is 999Hrs 59Mins.
Provided with RS-232C communication interface device, capable of controlling/ editing/ editing recording in line linkage with the computer and two set dynamic connection point (TIMER SIGNAL REPLAY) and convenient application.
Features
Strong counter-rotating mixture of high and low temperatures.
Features automatic positioning in both horizontal and vertical axes, plus pre warming, pre-cooling and recording of shock results.
Uses the Garden DO2ts heating oil in hot and cold chambers to minimize the costs of oil changes.
Large LCD (320 x 240 dots) with Chinese / English display of temperatures, with programmable mini-computer control system.
This system is suitable for on-site use with choice of water cooling or air cooling.
Features
Made entirely of P.P & PVC, resistant to acids, bases and heat. It can be used with salt spray acetic acid, or any other testing material.
Patented nozzle and conical dispersion unit ensure even spraying rate
It can be controlled manually, or for up 9,991 hours of operation
At the end of the experiment, a defogger automatically cleans the inside of the testing chamber for specimen.
Three set temperature controlling systems of air-tank temperature, test area temperature, solution temperature. To make sure the correctness amd standard of the testing.
Features
System capacity: It could sign in 150 programs x 1500 partitions, partitions can be optionally divided and program can link up to each other.
Loop configuration: 9999 x 999 looping time, can be divided into 5 independent sub-loops
Output: Intelligent PID + SSR/ SCR two-way synchronous output, built-in advanced slope control logic
Data: Touch panel dialogue box display, easy operation, built-in managemnet system of data content
Curves drawing: When temperature, humidity and times are set up, the data can be immediately transferred into curves, actual operating curves can be attained during operations
Features
Adopt computerized electronic digital control, precise & reliable.
The packing of box insulation is molded by silicone, high-temperature enduring & never aged attached with observation view window, easy to be used
Heating is by compulsory circulating ventilation, temperature raising is fast and spread even
Provide the P.I.D control system, double sided overheating protection, safe & reliable.
Easy to set temperature, easier to operate
Attached with two sets of moveable disks to be adjusted high and low at your dispel
Features
On desk design affords small volume with occupying space
All programmed instructions are microprocessor-controlled. with PID and automatic calculation to ensure precise and stable temperature and humidity control.
In the case of thermostat breakdown, a warning light switches on and temperature setting is changed to standard
Heat is evenly distributed throughout the testing chamber to ensure a uniform testing temperature
Features
The design mode of these sets is one body affords convenient application and less space occupation.
It can separately test high temperature and constant temperature and humidity.
All systems are individual and independent. The three sets type of the refrigstion system and three sets of the type heating and humidifying systems are adopted. The three set type systems afford stable control and high accuracy, prolonging the service life machine parts.
All programmed instructions are microprocessor-controlled, with PID and automatic calculation to ensure precise and stable temperature and humidity control.
Features
Stainless steel #304 interior and painted galvanized steel exterior for long life and beautiful appearance.
Fitting the large number or volume testing.
Power all linking control to provide the best safety.
The internal volume may be randomly enlarged and contracted which design is depending on the environmental requirement of the user.
And the move would be many fast when customer want to changer to another factory
Adopt the Japanese Micro-Computer control system of English/ Chinese display with big size LCD (320*240 dots(. High function and simple to operate.
Provide with RS-232 communication interface device, capable of linking with a computer to control, edit, record, and connect timer signal delay
Features
This equipment features independent systems with vibration control and cross-temperature and cross-humidity controls. It can be set to test and display results for high temperatures, low temperatures, cross temperatures and humidity and vibration, either individually or at the same time.
Moveable guide rails for easy testing separately or simultaneously.
Large LCD display in Chinese or English plus 100-program memory and standard RS-232C computer interface.
Features
Fully automatic calibrator with built-in pump and controller
Switchable internal pressure modules for expandable ranges
Accuracy (1 year) of 0.02%FS
External pressure modules available (measure only)
Less than 4 lbs (1.8 kg) for handheld operation
Source pressure, measure pressure and electrical
4 channels
Optional HART communications
Optional data logging and task documenting
USB and Wi-Fi communication
ISO 17025-accredited calibration w/data included
Features
Generates stable humidity and temperature conditions (<+-0.1% RH, <+-0.01 Degree Celsius)
Calibration solution for the laboratory and on-site
Humidity equilibrium typically in only 5 minutes for HG2-S, 15 minutes for HG2-XL
Calibrate multiple probes simultaneously
<< Auto >> Automated calibration optional
<< Remote API >>logging and control with third party software (optional)
Integrated FDA 21 CFR part 11 compliant Rotronic HW4 software
Features
Temperature range from 33°C to 660°C
Portable, rugged, and quick to temperature
Metrology-level performance in stability, uniformity, accuracy and loading effect
Dual-zone control
Full HART field communicator
Process calibrator option provides a multi-channel readout for a reference thermometer,RTDs and TCs,task documentation, and HART Communication
Color touch screen display
Choose your own range option
Set point control by reference
Self-calibration feature
Features
Accuracy to 0.01% of reading
Small and rugged handheld design
Measure, source, or simulate loop current
Measure DC volts
Simultaneously mA and % span display
Switch functionality
Selectable ramp and step functions
Easy to read display and user interface
HART 250Ω resistor in series with 24V loop
Page load link