Skip to content
Characteristics
Stainless Steel Sensor
Nominal pressure ranges from 1 mbar up to 20 bar
Accuracy according to IEC 60770: 0.075 % FSO
Preferred areas of use are Process, Oil And Gas Industry
Characteristics
Ceramic Sensor
Nominal pressure ranges from 0 ... 160 mbar up to 0... 20 bar
Accuracy according to IEC 60770: 0.1 % FSO
Preferred areas of use for Process, Oil And Gas Industry
Characteristics
Stainless Steel Sensor
Nominal pressure ranges from 0 ... 400 mbar up to 0 ... 40 bar
Accuracy according to IEC 60770: 0.1 % FSO
Preferred areas of use for Flush, Hygienical Application
Characteristics
Ceramic Sensor
Nominal pressure ranges from 0 ... 160 mbar up to 0... 20 bar
Accuracy according to IEC 60770: 0.1 % FSO
Preferred areas of use for Flush, Hygienical Application
Features
App integration via Bluetooth for fast and convenient monitoring and reporting on site
Refrigerant update in the instrument via App
Calculation of superheating/subcooling in real time with up to two external temperature probes
2-way valve block with three connections, three hose parkers and sight glass
250 hours‘ battery life
Features
Nominal pressure: 0 ... 2 bar up to 0 ... 400 bar
Accuracy: 1 % FSO
1 or 2 contacts
Configurable via PC or programming device P6
Diaphragm ceramic (96 %)
Optional Features
Oil- and grease free application
Areas of Application
Mechanical and plant engineering
Energy Industry
Features
nominal pressure: 0 ... 400 mbar up to 0 ... 600 bar
accuracy: 0.5 % FSO
rotatable and configurable display module
indication of measured values on a 4-digit LED display
1 or 2 independent PNP contacts, freely configurable
Optional Features
IS-version
Ex ia = itrinsically safe for gases
pressure port PVDF
customer specific versions
Areas of Application
Mechanical and plant engineering mechanical and plant engineering
Environmental industry environmental industry
Features
Nominal pressure: 0 ... 100 mbar up to 0 ... 40 bar
Accuracy: 0.35 % (opt. 0.25 %) FSO
1 or 2 independent PNP contacts, freely configurable
Indication of measured values on a 4-digit LED display
Rotatable and configurable display module
Hygienic process connections with flush stainless steel diaphragm
Configurable contacts (switch on / switch off points, hysteresis / window mode, switch on / switch off delay)
Optional Features
IS-version - Ex ia = intrinsically safe for gases
Analog Output - 2-wire: 4 ... 20 mA, 3-wire: 4 ... 20 mA with Turn Down 1:5, 0 ... 10
Customer Specific Versions
Areas of Application
Medical Technology
Food and Beverage
Features
Nominal pressure: 0 ... 100 mbar up to 0 ... 600 bar
Accuracy: 0.35 % (opt. 0.25 %) FSO
Indication of measured values on a 4-digit LED display
Rotatable and configurable display module
1 or 2 independent PNP contacts, freely configurable
Optional Features
IS-version - Ex ia = intrinsically safe for gases and dust
Pressure sensor welded
Customer Specific Versions
Areas of Application
Mechanical and plant engineering
HVAC
Environmental industry
Characteristics
nominal pressure ranges from 0 ... 1 bar up to 0 ... 10 bar also -1 ... 0 bar
1 or 2 contacts
Compact design
Configurable via PC or programming device P6
Applications
Pneumatic
Vacuum technology
Features
Nominal pressure: 0 ... 100 mbar up to 0 ... 600 bar
Accuracy: 0,35 % FSO
Analog output (optional): 4 ... 20 mA or 0 ... 10 V
Indication of measured values on a 4-digit LED display
Parametrization by IO-Link or set menu system (VDMA-conform)
Rotatable and configurable display
2 contacts
Optional Features
different mechanical connections
customer specific versions
Areas of Application
Mechanical and Plant Engineering
Hydraulics
Packaging and Paper Industry
Features
Nominal pressure: 0 ... 6 mbar up to 0 ... 1000 mbar
Accuracy: 0,35 % FSO
Aluminum housing
Rotatable and configurable display module
4-digit LED display
Suited for non-aggressive gases and compressed air
Optional Features
1 / 2 PNP contacts
customer specific versions
Areas of Application
Mechanical and plant engineering
HVAC
Features
Nominal pressure: 0 ... 2 bar up to 0 ... 400 bar
Accuracy: 1.5 % FSO
Display and housing rotatable
Up to 2 contacts
Configurable via display
Optional Features
Areas of Application
Mechanical and Plant Engineering
Energy Industry
Features
Nominal pressure: 0 ... 6 bar up to 0 ... 600 bar
Accuracy: 0.5 % FSO
1 analog output and up to 2 contacts
Display and housing rotatable
Perfect for oxygen applications
Areas of Application
Mechanical and Plant Engineering
Energy Industry
Refrigeration Engineering
Medical Technology
Utility Vehicles / Mobile Hydraulics
Features
Nominal pressure: 0 ... 600 bar up to 0 ... 2200 bar
Accuracy: 0,35 % FSO
Indication of measured values on a 4-digit LED display
Rotatable and configurable display module
1, 2 or 4 independent PNP contacts, freely configurable
Pressure sensor welded
Extremely robust and excellent longterm stability
Optional Features
Adjustability of span and offset (4 ... 20 mA / 3-wire)
Customer specific versions
Areas of Application
Mechanical and Plant Engineering
Utility Vehicles / Mobile Hydraulics
Features
Nominal pressure: 0 ... 10 mbar up to 0 ... 1000 mbar
Accuracy: 0.35 % FSO
Indication of measured values on a 4-digit LED display
Rotatable and configurable display module
1, 2 or 4 independent PNP contacts, freely configurable
Optional Features
IS-version: Ex ia = intrinsically safe for gases
Customer specific versions
Areas of Application
Mechanical and Plant Engineering
HVAC
Laboratory
Features
Nominal pressure: 0 ... 6 bar up to 0 ... 600 bar
Accuracy: 0.5 % FSO
Indication of measured values on a 4-digit LED display
Rotatable and configurable display module
1, 2 or 4 independent PNP contacts, freely configurable
Optional Features
IS-version: Ex ia = intrinsically safe for gases
Oxygen application
Customer specific versions
Areas of Application
Mechanical and Plant engineering
Energy Industry
Refrigeration Engineering
Medical Technology
Utility Vehicles / Mobile Hydraulics
Features
Nominal pressure: 0 ... 60 bar up to 0 ... 400 bar
Accuracy: 0.5 % FSO
1, 2 or 4 independent PNP contacts, freely configurable
Rotatable and configurable display module
Indication of measured values on a 4-digit LED display
Optional Features
IS-version - Ex ia = intrinsically safe for gases
Cooling element up to 300°C
Customer specific versions
Areas of Application
Mechanical and Plant Engineering
Food and Beverage
Features
Nominal pressure: 0 ... 400 mbar up to 0 ... 600 bar
Accuracy: 0.5 % FSO
Indication of measured values on a 4-digit LED display
Rotatable and configurable display module
1, 2 or 4 independent PNP contacts, freely configurable
Optional Features
IS-version: Ex ia = intrinsically safe for gases
Pressure port PVDF
Customer specific versions
Areas of Application
Mechanical and Plant Engineering
Environmental Industry
Features
Nominal pressure: 0 ... 100 mbar up to 0 ... 40 bar
Accuracy: 0.35 % (opt. 0.25 %) FSO
Rotatable and configurable display module
Indication of measured values on a 4-digit LED display
1, 2 or 4 independent PNP contacts, freely configurable
Configurable contacts (switch on / switch off points, hysteresis / window mode, switch on / switch off delay)
Optional Features
IS-version : Ex ia = intrinsically safe for gases
Customer specific versions
Analogue output
Areas of Application
Medical Technology
Food and Beverage
Characteristics:
Stainless Steel Sensor
nominal pressure ranges from 0 ... 100 mbar up to 0 ... 600 bar
Accuracy according to IEC 60770: Standard: 0.35 % FSO option: 0.25 % FSO
Characteristics :
Stainless Steel Sensor, Process, Oil And Gas Industry
Differential pressure ranges from 1 mbar up to 20 bar
Accuracy according to IEC 60770: 0.075 % FSO
Characteristics:
Stainless Steel Sensor, Test Engineering, Machine And Plant Engineering
Differential pressure ranges from from 10 mbar up to 20 bar
Accuracy according to IEC 60770: 0.35 % FSO
Characteristics:
Silicon Sensor, HVAC Medical
Differential pressure ranges from 0 ... 1.6 mbar up to 0 ... 1000 mbar
Accuracy according to IEC 60770: 0.5% FSO BFSL
Characteristics
Piezoresistive silicon sensor
Differential pressure range 6 ... 1000 mbar
Application for for HVAC-applications
Characteristics
Stainless Steel Sensor
Nominal pressure from 0 ... 400 mbar up to 0 ... 600 bar
accuracy according to IEC 60770: 0.1 % FSO
Preferred areas of use for Process, Oil And Gas Industry
Communication interface for adjusting of offset, span and damping
Characteristics
Stainless Steel Sensor
Nominal pressure ranges from
Accuracy according to IEC 60770:
standard: 0.35 % FSO
option: 0.25 % FSO
Characteristics
Stainless Steel Sensor, Without Media Isolation, HVAC
Nominal pressure ranges from 0 ... 10 mbar up to 0 ... 1000 mbar
Accuracy according to IEC 60770: 0.35 % FSO
Characteristics
Stainless Steel Sensor Flush Version G 1/4
Nominal pressure ranges from 0 ... 60 bar to 0 ... 600 bar
Accuracy according to IEC 60770: 0.35 % FSO
Characteristics
Welded, Dry Stainless Steel Sensor
Nominal pressure range from 0 ... 6 bar up to 0 ... 600 bar
Accuracy according to IEC 60770: 0.5 % FSO
Preferred areas of use for Medical Technology
Characteristics
Thinfilm Sensor
Nominal pressure ranges from 0 ... 600 bar up to 0 ... 2200 bar
Accuracy according to IEC 60770: 0.1 % FSO
Preferred areas of use for Welded, Plant And Machine Engineering
Characteristics
Thinfilm Sensor
Nominal pressure range from 0 ... 600 bar up to 0 ... 2200 bar
Accuracy according to IEC 60770: 0.35 % FSO
Preferred areas of use for Plant & Mechanical Engineering
Characteristics
Stainless Steel Sensor
Universal Application
Nominal pressure from 0 ... 100 bar up to 0 ... 600 bar
Accuracy according to IEC 60770:
standard: 0.35 % FSO
option: 0.25 / 0.1 % FSO
Characteristics
Process Connections with Flush Welded Stainless Steel Diaphragm
Hygienical Application
Nominal pressure range from 0...100 mbar Up To 40 bar nominal pressure
Accuracy according to IEC 60770: 0.1 % FSO
Characteristics
Pressure Ports and Process Connections with Flush Welded Stainless Steel Diaphragm
Nominal pressure ranges from 0 ... 400 mbar up to 0 ... 40 bar
Accuracy according to IEC 60770: 0.1 % FSO
Characteristics
Stainless Steel Sensor
Universal Application
Nominal pressure ranges from 0...100mBar Up To 60 bar
Accuracy according to IEC 60770:
standard: 0.35 % FSO
option: 0.25 / 0.1 % FSO
Page load link