Skip to content
Features
°F/°C selectable
Min/Max memory stores lowest/highest readings
Automatic calibration feature
IP65 Waterproof
Reduced Tip Probe
Complies with FDA Food Code 4-203.11
Features
NSF certified
°F/°C selectable
Min/Max memory stores lowest/highest readings
Automatic calibration feature
IP65 Waterproof housing
Small-diameter probe ideal for measuring temperature of "thin mass" food such as meat patties and chicken/fish fillets (FDA Food Code 4-302.12 (B).
Features
Dual Input
Dual Display
Auto Powe Off
RS-232 Interface
REL Function
HOLD Function
MAX AVG MIN Function
Resolution 0.1°C 0.1°F
Low Battery Indication
Features
Dual Input
Triple Display
Time Function
RS-232 Interface
With Window Software
16,000 Records Data logger
Auto Power Off
REL Function
MAX MIN Function
Resolution 0.1°C 0.1°F
Low Battery Indication
Features
Auto Range
PC Interface
LED Backlight
HOLD Function
Four Channel Input
Four Channel Display
Resolution 0.1°C 0.1°F
With Windows Software
MAX MIN Function
Auto Shut Off for battery saving
16,000 Records Data logger each channel
Features
Measuring Range : -200 to +1772°C
High Accuracy and Fast Response
Digital LCD Display with Back-Light
Records Max./Min. Values
RS-232 Signal Output
CE and ROHS Approved
Features
High Resolution 0.01 (-200.00 ~ + 1372.00°C)
Dual Type K (CA) input
P66 Water-Proof
USB / RS-232 Output
High / Low Alarm
T1-T2 / Max. / Min. / Avg.
Large Display LED Back-Light
Feature
High Resolution : 0.01°
IP66 Water-Proof
Accept PT100 and PT1000Ω Input
Dual Probes (T1-T2)
Large LCD Display with LED Back-Light
Hold / Max. / Min. / Average
High / Low Alarm Setting
USB / RS-232 Output
CE and RoHS Approved
Features
K.J.E.T.N.R.S.B Eight Types Available
Concise Buttons and Operation Interface
Carry Out Simple and Durable Principles
Very Practical and Low Prices
Fast Response and High Accuracy
RS-232 Signal Output
CE and RoHS Approved
Features
IP66 Water-Proof
Accept 9 T/C Types
Dual Probes (T1-T2)
Data-Logger Built-In
USB/RS-232 Output, with Software
Fine Adjustment Function
Hi/Lo Alarm
Max./Min./Avg./Hold
LED Back-Light
CE and RoHS Approved
Lightweight, compact, 2-in-1 design
Thermocouple probe for internal product temperature
Infrared for instant non-contact surface measurement
Multi-beam laser for accurate targeting
Ideal for extremely hot areas, moving objects, hard to reach places
Green backlight indicates HACCP food safety zone
Red backlight indicates HACCP danger zone
Min/Max memory in IR mode
NSF Certified, NIST traceable
Fast 3 second thermocouple reading
Instant infrared reading
Low battery indicator
Main Function
Heating / cooling output
Independent timer output
High / Low alarm output
Defrost output
Precise temperature control
Sensor correction
Sensor error detection
Data back up
Minimum on/off maintaining time setup
RS485 communication (MODBUS)
Transmission output
Auto-output operation cycle settable in case of sensor error
Main Function
Heating / cooling output
Independent timer output
High / Low alarm output
Defrost output
Precise temperature control
Sensor correction
Sensor error detection
Data back up
Minimum on/off maintaining time setup
RS485 communication (MODBUS)
Transmission output
Auto-output operation cycle settable in case of sensor error
Main Function
Heating / cooling output
High / Low alarm output
Precise temperature control
Sensor correction
Sensor error detection
Data back up
Minimum on/off maintaining time setup
RS485 communication (MODBUS)
Transmission output
Main Function
Heating / cooling output
Precise temperature control
Sensor correction
Sensor error detection
Data back up
Minimum on/off maintaining time setup
Auto-output operation cycle settable in case of sensor error
Main Function
Heating/cooling output
High / Low alarm output
Precise temperature control.
Sensor correction, sensor error detection
Sensor error detection
Data backup
Min. on/off maintaining time setup
Transmission output
RS485 communication (MODBUS)
Main Function
Heating / cooling output
Independent timer output
High / Low alarm output
Precise temperature control
Sensor correction
Sensor error detection
Data back up
Minimum on/off maintaining time setup
RS485 communication (MODBUS)
Transmission output
Main Function
Total control and detection (protection) for freezers
Function of start, restart, pump down, alarm delay timer
Discharge gas detection (high & low temperature)
Individual alarm message (OC, HP, LP, OP, INT)
RS485 communication (MODBUS)
Main Function
PID degree of superheat control through defense and safety compensation
Degree of superheat control for various refrigerant
PMW (opening ratios control)
Remote operation
Transmission output
RS485 communication (MODBUS)
Main Function
Defrosting (auto / manual)
Fan control
Efficient delay
Room temperature sensor: 1EA
Defrost sensor: 1EA
High (low) temperature alarm output
Room temperature transmission output (4~20 mA)
RS485 communication (MODBUS)
Main Function
Efficient defrosting in geothermy heat pump system
Defrosting execution by measuring of ambient humidity and temperature
Main Function
Uniform step control
Operation with intelligent shift high / low alarm output
Sensor correction / Sensor error detection
Transmission output
RS485 communication (MODBUS)
Main Function
Defrosting (auto / manual)
Defrosting stop delay
Evaporation fan control
Air inlet/outlet sensor: 2EA
Defrost recovery sensor: 1EA
Virtual temperature sensor computing
Door open alarm
Emergency call
Night operation
High (low) temperature alarm output
RS485 communication (MODBUS)
Main Function
Defrosting (auto / manual)
Defrosting stop delay
2 air inlet/outlet sensors
One sensor for defrost recovery
High / Low alarm output
Indicator (FixView) connection
RS485 communication (MODBUS)
Main Function
Embedded run/stop switch, motor on/off, load run, auto-stop, manual stop, operation delay, load delay, embedded timer
Pressure / temperature high level
Temperature low level (standby for starting)
Interlock input signal (emergency switch, OCR reverse phase)
Usable thermometer and manometer
RS485 communication (MODBUS)
Main Function
Embedded run/stop switch, motor on/off, load run, auto-stop, manual stop, operation delay, load delay, embedded timer
Pressure / temperature high level
Temperature low level (standby for starting)
Interlock input signal (emergency switch, OCR reverse phase)
Usable thermometer and manometer
RS485 communication (MODBUS)
Main Function
3 stage fan speed controllable
4 kind (stop / high / middle / low) airflow choosable
Unification of temperature control function
Data backup
Self diagnostic
RS485 communication (MODBUS)
Main Function
Output controllable based on measured pressure value (increase and decrease)
Alternative operation available between freezing exclusive model and booster
Pump unit control model
RS485 MODBUS
Features
-35 to +80°C (-31 to +176°F) measurement range
Stores over 16,000 readings
EasyLog software available as a free download
Logging rates between 2 seconds and 1 hour
Immediate and delayed logging start
User-programmable alarm thresholds
Status indication via red/green and amber LEDs
Features
-35 to +80°C (-31 to +176°F) measurement range
Stores over 16,000 readings
EasyLog software available as a free download
Logging rates between 2 seconds and 1 hour
Immediate and delayed logging start
User-programmable alarm thresholds
Status indication via red/green and amber LEDs
Features
-40 to +125°C (-40 to +257°F) measurement range
Stores over 32,000 readings
EasyLog software available as a free download
Logging rates between 2 seconds and 1 hour
Immediate and delayed logging start
User-programmable alarm thresholds
Stainless steel (316 grade) case
Features
-20 to +60°C (-4 to +140°F) measurement range
Stores over 32,000 readings
EasyLog software available as a free download
Logging rates between 2 seconds and 1 hour
Immediate and delayed logging start
User-programmable alarm thresholds
Stainless steel (316 grade) case
Features
-10 to +50°C (-14 to +122°F) measurement range
Stores over 4,000 readings
EasyLog software available as a free download
30 minutes logging rate
Immediate and delayed logging start
User-programmable alarm thresholds
Features
Compatible with K, J and T-type thermocouple with miniature thermocouple plug connection
Stores over 32,000 readings
Logging rates between 1 second and 12 hours
Immediate and delayed logging start
EasyLog software available as a free download
Supplied with 1.5m K-type thermocouple probe with 0 to 200°C (32 to 392°F) measurement range
Features
Compatible with K, J and T-tyoe thermocouple with miniature thermocouple plug connection
Stores over 32,000 readings
Logging rates between 1 second and 12 hours
Immediate and delayed logging start
EasyLog software available as a free download
Supplied with 1.5m K-type thermocouple probe with 0 to 200°C (32 to 392°F) measurement range
Features
-40 to +125°C (-40 to +257°F) measurement range
Stores over 32,000 readings
EasyLog software available as a free download
Logging rates between 1 second and 12 hour
Immediate, delayed and push-to-start logging
User-programmable alarm thresholds
Page load link
Notice : ob_end_flush(): failed to send buffer of zlib output compression (0) in /home/acezphil/public_html/wp-includes/functions.php on line 5464