- Eliminates the cost of wiring AC power to each monitored point
- Data loggers can be installed wherever a LAN cable can be run
- Increased data communication protection from power outage because the server room's UPS can provide backup power
- Plug and Play connectivity when using viewLinc Aware function
-
Features
-
Features
- Large onboard memory allows mapping studies of almost any length
- Compact, battery powered loggers mean no complex wiring or lengthy setup
- All files are encrypted and reports are 21 CFR Part 11 and Annex 11 compliant
- Optional, comprehensive IQ/OQ protocols save time and costs
- Batch set-up, download, and audit trail filtering make report analysis fast and easy
- Localized versions of vLog software are available in Chinese, Japanese and French
-
Features
- Software for continuous monitoring of temperature, humidity and other parameters
- Eight language versions for enterprise-wide, multi-site use
- Preconfigured and custom reports
- Configurable alarm notifications: email, SMS, voice calls, signal towers, browser alerts
- Scheduled threshold alarming and alarm notification delivery times to accommodate maintenance periods or work shifts
- Interactive tours — built-in guidance for novice users
- Licensed features: Voice/SMS web service, third-party Modbus devices, Vaisala OPC UA Server, REST API
-
Features
- System validation documentation package designed to provide ISPE Good Automated Manufacturing Practice (GAMP) methodology for viewLinc system validation.
- Available in English, Portuguese, Japanese, and Chinese.
- Specify the required attributes of your viewLinc system using the viewLinc-specific GxP documentation:
- User Requirements Specification
- Functional Specification
- Design Qualification
- Traceability Matrix
- Risk Assessment
-
Features
- Industry-leading measurement precision
- Interchangeable high-accuracy probes for T, RH, and CO2
- 30-day memory buffer
- Typical battery life of 18 months in RH and T measurement
- Uses standard alkaline batteries
- Probe calibrations are traceable to SI units through national metrology institutes or accredited calibration laboratories
- Cost-effective alternative to chart recorders
-
Features
- Measurements are traceable to the International System of units (SI) through national metrology institutes.
- Software options include vLog for Validation/Mapping and viewLinc continuous monitoring and alarming.
- The Vaisala OPC-DA Server software can be used to integrate Vaisala DL-series data loggers to non-Vaisala systems
-
Features
- Measurement independent of oil type, age and temperature - indicates margin to oil saturation
- In-line process checking through ball valve, no need to drain the oil
- Rugged and reliable construction
- Multi-probe operation; dewpoint and CO2 probes can also be connected
- Vaisala HUMICAP Sensor - proven field performance since 1973
-
Features
- Online service for monitoring of measurement parameters such as humidity and temperature
- Secure cloud storage of data
- Management of measurement locations using an intuitive system of sites and locations
- Connect using a web browser on your mobile phone, tablet or computer
- Add devices and users based on your needs
- No device pairing needed, as devices are associated with a specific cloud account when they are purchased
-
Features
- Numerical and graphical color display for up to 3 parameters
- IP65 metal housing
- Support for one Indigo compatible probe
- Tool-free locking wheel for the probe
- 24 V AC/DC power supply input
- 3 pre-configured analog outputs (mA or V)
- Service port on the front for connecting to Vaisala Insight PC software or Indigo80 handheld indicator
-
Features
- Intrinsically safe (Exi) for operation in up to Zone 0 / 20
- Measures RH and T and outputs an extensive range of calculated parameters: for a full list, see Technical data (page 5).
- Designed for harsh conditions
- Temperature range between −70 … +180 °C (−94 … +356 °F) depending on the probe option
- Vaisala HUMICAP sensor features high accuracy, excellent long-term stability, and negligible hysteresis
- Display options: graphical LCD display and non-display model
- Traceable calibration (certificate included)
- Compatible with Vaisala Insight PC software
-
Features
-
Six models for demanding industrial applications
-
Full 0 ... 100 %RH measurement, wide temperature range -40...+180 °C (-40...+356 °F)
-
Pressure tolerance up to 100 bar
-
Excellent performance in harsh conditions; good chemical tolerance
-
Corrosion-resistant IP65/IP66 housing
-
5-point calibration (certificate included)
-
Two analog outputs, calibrated (certificate included)
-
RS232, ASCII output
-
-
Features
- Miniature probe head with low thermal mass for superior response time
- RH accuracy up to 0.8 %RH
- Temperature accuracy up to 0.1 °C (0.18 °F)
- Temperature measurement range −40 … +120 °C (−40 … +248 °F)
- Sensor purge provides superior chemical resistance
- Modbus RTU over RS-485
- Compatible with Indigo transmitters and Insight PC software
- Traceable calibration certificate: 6 points for humidity, 1 point for temperature
- M10×1.5 cable gland included for mounting the probe head
-
Features
- RH accuracy up to 0.8 %RH, Temperature accuracy up to 0.1 °C (0.18 °F)
- Temperature measurement range -70 ... +180 °C (-94 ... +356 °F)
- Vapor and pressure proof construction
- Probe and sensor warming functions minimize condensation on probe
- Sensor purge provides superior chemical resistance
- Plug & play compatible with Indigo series of transmitters
- Modbus RTU over RS-485
- Traceable calibration certificate: 6 points for humidity, 1 point for temperature
-
Features
- RH accuracy up to 0.8 %RH, Temperature accuracy up to 0.1 °C (0.18 °F)
- Temperature measurement range -70 ... +180 °C (-94 ... +356 °F)
- 250 mm (9.84 in) probe allows easy process installation through insulation
- Sensor purge provides superior chemical resistance
- Modbus RTU over RS-485
- Plug & play compatible with Indigo series of transmitters
- Traceable calibration certificate: 5 points for humidity, 1 point for temperature
- Sintered AISI316L filter standard in delivery
-
Features
- RH accuracy up to 0.8 %RH, Temperature accuracy up to 0.1 °C (0.18 °F)
- Temperature measurement range -70 ... +180 °C (-94 ... +356 °F)
- Operating pressure 0 ... 10 MPa (0 ... 100 bar)
- Sensor purge provides superior chemical resistance
- Modbus RTU over RS-485
- Plug & play compatible with Indigo series of transmitters
- Traceable calibration certificate: 5 points for humidity, 1 point for temperature
-
Features
- Compact size
- RH accuracy up to ±1.0 %RH
- Temperature accuracy up to ±0.2 °C (0.36 °F)
- Temperature measurement range −40 … +60 °C (−40 … +140 °F)
- Chemical purge provides superior chemical resistance
- Modbus RTU over RS-485
- Compatible with Indigo series transmitters and Insight PC software
- Traceable calibration certificate: 6 points for humidity, 1 point for temperature
-
Features
- Measured parameters: carbon dioxide, temperature, and humidity (optional)
- Superior long-term stability with the latest-generation Vaisala CARBOCAPâ sensor
- Accurate temperature and humidity measurements due to the low-power microglow infrared source
- Quick and easy installation and maintenance
- Calibrated, user-exchangeable measurement modules
- 23-point traceable CO2 calibration (certification included)
- Both analog and field bus communication (Modbusâ RTU)
-
Features
- Two optional sampling methods: diffusion or pump aspiration
- User-friendly meter with multilingual user interface
- Numerical and graphical display of measurements
- Data can be logged and transferred to PC via MI70 Link software
- Multiprobe operation: Vaisala’s relative humidity and dew point probes can be used simultaneously with CO2 measurement
-
Features
- The first transmitter that monitors both dew point and process pressure
- A simple and convenient transmitter for monitoring of compressed air
- Highly accurate humidity information thanks to dew point data coupled with live pressure input
- Compatible with the Vaisala Hand-Held DM70 for easy spot-checking, local display and data logging
- Pressure: 1 … 12 bar
- Dew point: -70 … +30 °C (-94 ... +86 °F)
- Digital output RS-485 with MODBUS
-
Features
- Measures dew point from -70 ... +80 °C (-94 ... +176 °F) with an accuracy of ±2 °C (±3.6 °F)
- Condensation-resistant
- Unique auto-calibration feature maintains accuracy over long term
- Compatible with Vaisala DRYCAP Handheld Dew Point Meter DM70
- Traceable calibration to measurements and analog outputs (certificates included)
- Graphical display and keypad for convenient operation
- Optional alarm relays and mains power supply module
- Up to three analog outputs, RS-232/485, LAN
- Modbus protocol support (RTU/ TCP)
-
Features
- Dew point measurement range −70 … +80 °C (−94 … +176 °F) Td/f
- Dew point measurement accuracy up to ±2 °C (±3.6 °F) Td/f
- Operating pressure of probe head 0 … 4 MPa (0 … 40 bar)
- Adjustable installation depth
- Tolerates condensation, oils, dust, and most chemicals
- Sensor purge provides superior chemical resistance
- Modbus RTU over RS-485
- Compatible with Indigo transmitters and Insight PC software
- Traceable calibration certificate
-
Features
- Dew point measurement range −70 … +80 °C (−94 … +176 °F) Td/f
- Dew point measurement accuracy up to ±2 °C (±3.6 °F) Td/f
- Sensor purge provides superior chemical resistance
- Tolerates condensation, oils, dust, and most chemicals
- Modbus RTU over RS-485
- Compatible with Indigo transmitters and Insight PC software
- Traceable calibration certificate
-
Features
- Measures humidity at high temperatures up to +350 °C (+662 °F)
- Dew point measurement range −25 … +100 °C (−13 … +212 °F) Td/f
- Dew point measurement accuracy up to ±2 °C (±3.6 °F) Td/f
- Sensor purge provides superior chemical resistance
- Condensation-tolerant Modbus RTU over RS-485
- Compatible with Indigo transmitters and Insight PC software
- Traceable calibration certificate
-
Features
- Measures humidity at temperatures up to +180 °C (+356 °F)
- Dew point measurement range−40 … +100 °C (−40 … +212 °F) Td/f
- Dew point measurement accuracy up to ±2 °C (±3.6 °F) Td/f
- Sensor purge provides superior chemical resistance
- Condensation-tolerant
- Modbus RTU over RS-485
- Compatible with Indigo transmitters and Insight PC software
- Traceable calibration certificate
-
Features
- Designed for industrial spot checking and field calibration
- Three models: accurate measurement ranges from −60 to +60 °C (−76 ... +140 °F)
- Vaisala DRYCAPâ sensor with unique auto calibration function
- Sensor withstands condensation
- Data can be logged and transferred to a PC via MI70 Link software
- Traceable calibration (certificate included)
- Fast response, enhanced by sensor purge option
- Variety of sampling cell options for connection to pressurized processes
-
Features
- Single and multi-channel models with up to four input channels
- Easily set scaling and measurement units for recording
- Time-based digital recording in a range of sample intervals
- Multiple connectivity options - USB, Ethernet, WiFi
- Optional vNet cradle for Ethernet or Power over Ethernet connectivity
- Traceable to SI units through national metrology institutes.
- 10-year battery and large onboard memory
- Two year limited warranty
-
Features
- Industry-leading temperature and relative humidity measurement precision
- High accuracy, adjustable timebased digital recording
- Printed reports for any time period
- Ability to perform validation and continuous monitoring with the same model
- Traceable to SI units through national metrology institutes
- Superior alternative to chart recorders and hard-wired systems
- Integrated high-accuracy RH sensor
- 10-year battery
-
Features
- Industry-leading precision and accuracy
- Real-time monitoring & alarming with viewLinc software
- Reliable validation/mapping with vLog software
- Easy connectivity to your existing network – wired or wireless
- Validation and continuous monitoring with the same datalogger
- Superior alternative to chart recorders and hard-wired systems
- Traceable to SI units through national metrology institutes
-
Features
- Industry-leading precision and accuracy
- Printed reports for any time period
- Internal battery with up to 10 years' lifetime
- Validation and continuous monitoring with the same model
- Superior alternative to chart recorders and hard-wired systems
- Timebase calibrated over the operating temperature range
- Adjustable time-based recording
- Snap-in logger cradle for easy network connectivity
- Two probe options give high accuracy – from −90 °C to +70 °C (−130 °F to +158 °F)
- Traceable to SI units through national metrology institutes
- 2-year limited warranty