- Lightweight, compact, 2-in-1 design
- Thermocouple probe for internal product temperature
- Infrared for instant non-contact surface measurement
- Multi-beam laser for accurate targeting
- Ideal for extremely hot areas, moving objects, hard to reach places
- Green backlight indicates HACCP food safety zone
- Red backlight indicates HACCP danger zone
- Min/Max memory in IR mode
- NSF Certified, NIST traceable
- Fast 3 second thermocouple reading
- Instant infrared reading
- Low battery indicator
-
-
Features
- Monitor vaccines in ultra-low temperatures
- Ideal for storage and transport with dry ice
- Minimum/Maximum memory for lowest and highest readings
- High and Low Alarms with audible buzzer and flashing red light
- Detachable external sensor with gold plated stereo jack connector
- Jumbo LCD
- Selectable ºC/ºF temperature scales
- Non-volatile memory retains settings during battery replacement
- Remaining battery indicator
- Mounts to vertical surfaces with strong built-in magnets
- Foldable stand for placement on flat surfaces
-
Features
- High/low alarm setting
- Glycol buffered probe emulates products and prevents false alarms during normal use
- Gold plated stereo jack connector reduces faulty readings
- Minimum/Maximum memory stores lowest/highest readings
- Jumbo LCD
- Switchable °F/°C scale
- Strong Magnetic attachment and fold-away stand
- Retains settings during battery replacement
- Configurable delay alarms with audible buzzer
- More than 1 year of continuous monitoring
- Ideal for monitoring vaccines and common fluids stored in refrigerators, freezers, and cold holding display cases
- High/low alarm setting
- Glycol buffered probe emulates products and prevents false alarms during normal use
- Gold plated stereo jack connector reduces faulty readings
- Minimum/Maximum memory stores lowest/highest readings
- Jumbo LCD
- Switchable °F/°C scale
- Strong Magnetic attachment and fold-away stand
- Retains settings during battery replacement
- Configurable delay alarms with audible buzzer
- More than 1 year of continuous monitoring
- Ideal for monitoring vaccines and common fluids stored in refrigerators, freezers, and cold holding display cases
-
Features
- Measuring range from -58°F to 158°F (-50°C to 70°C)
- Highly accurate up to ± 1°F (±0.5°C)
- High/low alarm settings
- Minimum/Maximum memory stores lowest/highest readings
- Stereo jack gold plated connector reduces faulty readings
- Jumbo LCD
- Switchable °F/°C scale
- Blunt probe sensor with 10 foot (3 meter) strain resistant cable
- Strong magnetic attachment and fold-away stand
- Retains settings during battery swap
- Configurable delay alarms with audible buzzer and/or flashing light
- More than 1 year of continuous monitoring
-
Features
- NSF Certified
- Sealed anti-microbial unibody construction
- Automatic calibration feature
- Needle tip ideal for measuring temperature of thin mass foods such as meat patties, chicken and fish fillets, per FDA Food Code 4-302.12 (B)
- Fast response time
- Highly visible dual scale jumbo LCD display
- IP56 waterproof, sanitizable, dirt and grease resistant
- Automatic shut off saves battery
- °F/°C selectable
-
Features:
- Digitize designing suitable for measuring rotational speed and observing stationary images
- Button operation, widely measurement range and high accuracy
- Automatic record the last speed value when the power is turned off
- Three complete setup memory storage
- Timer function 1, 5, 10 minutes or sustained (DS-9000 only)
-
Features
- nominal pressure: 0 ... 400 mbar up to 0 ... 600 bar
- accuracy: 0.5 % FSO
- rotatable and configurable display module
- indication of measured values on a 4-digit LED display
- 1 or 2 independent PNP contacts, freely configurable
- IS-version Ex ia = itrinsically safe for gases
- pressure port PVDF
- customer specific versions
- Mechanical and plant engineering mechanical and plant engineering
- Environmental industry environmental industry
-
Features
- Nominal pressure: 0 ... 100 mbar up to 0 ... 40 bar
- Accuracy: 0.35 % (opt. 0.25 %) FSO
- 1 or 2 independent PNP contacts, freely configurable
- Indication of measured values on a 4-digit LED display
- Rotatable and configurable display module
- Hygienic process connections with flush stainless steel diaphragm
- Configurable contacts (switch on / switch off points, hysteresis / window mode, switch on / switch off delay)
- IS-version - Ex ia = intrinsically safe for gases
- Analog Output - 2-wire: 4 ... 20 mA, 3-wire: 4 ... 20 mA with Turn Down 1:5, 0 ... 10
- Customer Specific Versions
- Medical Technology
- Food and Beverage
-
Features
- Nominal pressure: 0 ... 100 mbar up to 0 ... 600 bar
- Accuracy: 0.35 % (opt. 0.25 %) FSO
- Indication of measured values on a 4-digit LED display
- Rotatable and configurable display module
- 1 or 2 independent PNP contacts, freely configurable
- IS-version - Ex ia = intrinsically safe for gases and dust
- Pressure sensor welded
- Customer Specific Versions
- Mechanical and plant engineering
- HVAC
- Environmental industry
-
Features
- Nominal pressure: 0 ... 100 mbar up to 0 ... 600 bar
- Accuracy: 0,35 % FSO
- Analog output (optional): 4 ... 20 mA or 0 ... 10 V
- Indication of measured values on a 4-digit LED display
- Parametrization by IO-Link or set menu system (VDMA-conform)
- Rotatable and configurable display
- 2 contacts
- different mechanical connections
- customer specific versions
- Mechanical and Plant Engineering
- Hydraulics
- Packaging and Paper Industry
-
Features
- Nominal pressure: 0 ... 6 mbar up to 0 ... 1000 mbar
- Accuracy: 0,35 % FSO
- Aluminum housing
- Rotatable and configurable display module
- 4-digit LED display
- Suited for non-aggressive gases and compressed air
- 1 / 2 PNP contacts
- customer specific versions
- Mechanical and plant engineering
- HVAC
-
Features
- Nominal pressure: 0 ... 6 bar up to 0 ... 600 bar
- Accuracy: 0.5 % FSO
- 1 analog output and up to 2 contacts
- Display and housing rotatable
- Perfect for oxygen applications
- Mechanical and Plant Engineering
- Energy Industry
- Refrigeration Engineering
- Medical Technology
- Utility Vehicles / Mobile Hydraulics
-
Features
- Nominal pressure: 0 ... 600 bar up to 0 ... 2200 bar
- Accuracy: 0,35 % FSO
- Indication of measured values on a 4-digit LED display
- Rotatable and configurable display module
- 1, 2 or 4 independent PNP contacts, freely configurable
- Pressure sensor welded
- Extremely robust and excellent longterm stability
- Adjustability of span and offset (4 ... 20 mA / 3-wire)
- Customer specific versions
- Mechanical and Plant Engineering
- Utility Vehicles / Mobile Hydraulics
-
Features
- Nominal pressure: 0 ... 10 mbar up to 0 ... 1000 mbar
- Accuracy: 0.35 % FSO
- Indication of measured values on a 4-digit LED display
- Rotatable and configurable display module
- 1, 2 or 4 independent PNP contacts, freely configurable
- IS-version: Ex ia = intrinsically safe for gases
- Customer specific versions
- Mechanical and Plant Engineering
- HVAC
- Laboratory
-
Features
- Nominal pressure: 0 ... 6 bar up to 0 ... 600 bar
- Accuracy: 0.5 % FSO
- Indication of measured values on a 4-digit LED display
- Rotatable and configurable display module
- 1, 2 or 4 independent PNP contacts, freely configurable
- IS-version: Ex ia = intrinsically safe for gases
- Oxygen application
- Customer specific versions
- Mechanical and Plant engineering
- Energy Industry
- Refrigeration Engineering
- Medical Technology
- Utility Vehicles / Mobile Hydraulics
-
Features
- Nominal pressure: 0 ... 60 bar up to 0 ... 400 bar
- Accuracy: 0.5 % FSO
- 1, 2 or 4 independent PNP contacts, freely configurable
- Rotatable and configurable display module
- Indication of measured values on a 4-digit LED display
- IS-version - Ex ia = intrinsically safe for gases
- Cooling element up to 300°C
- Customer specific versions
- Mechanical and Plant Engineering
- Food and Beverage
-
Features
- Nominal pressure: 0 ... 400 mbar up to 0 ... 600 bar
- Accuracy: 0.5 % FSO
- Indication of measured values on a 4-digit LED display
- Rotatable and configurable display module
- 1, 2 or 4 independent PNP contacts, freely configurable
- IS-version: Ex ia = intrinsically safe for gases
- Pressure port PVDF
- Customer specific versions
- Mechanical and Plant Engineering
- Environmental Industry
-
Features
- Nominal pressure: 0 ... 100 mbar up to 0 ... 40 bar
- Accuracy: 0.35 % (opt. 0.25 %) FSO
- Rotatable and configurable display module
- Indication of measured values on a 4-digit LED display
- 1, 2 or 4 independent PNP contacts, freely configurable
- Configurable contacts (switch on / switch off points, hysteresis / window mode, switch on / switch off delay)
- IS-version : Ex ia = intrinsically safe for gases
- Customer specific versions
- Analogue output
- Medical Technology
- Food and Beverage
-
Features
- The first transmitter that monitors both dew point and process pressure
- A simple and convenient transmitter for monitoring of compressed air
- Highly accurate humidity information thanks to dew point data coupled with live pressure input
- Compatible with the Vaisala Hand-Held DM70 for easy spot-checking, local display and data logging
- Pressure: 1 … 12 bar
- Dew point: -70 … +30 °C (-94 ... +86 °F)
- Digital output RS-485 with MODBUS