- Rugged, reliable basic True-RMS clamp meter for measuring current up to 400 A
- Measures AC current to 400 A
- Measures AC voltage and DC voltage to 600 V
- Provides True RMS AC voltage and current for accurate measurements on non-linear signals
- Measures resistance to 4 kΩ with continuity detection
-
Features
- True-RMS digital multimeter with the features professional technicians prefer
- Increases productivity with manual and automatic ranging, Display Hold, Auto Hold, and Min/Max-average recording
- Measures AC and DC voltage to 1000 V
- Delivers accurate True-RMS AC current and voltage plus frequency, capacitance, resistance, continuity and diode measurements
- Safety rated CAT III 1000 V, CAT IV 600 V
-
Features
- Ideal Digital Multimeter for “go/no-go” testing
- Features AutoVolt automatic AC/DC voltage selection
- Includes low input impedance to help prevent false readings due to ghost voltage
- Presents a large white LED backlight for working in poorly lit areas
- Measures resistance and continuity
- Provides Min/Max/Average with elapsed time to record signal fluctuations
-
Features
- Large display
- Backlight for work in dim areas
- Min / Max to record signal fluctuations
- Ergonomic overmolded housing with integrated probe holders
- Free your hands with the optional TPAK magnetic hanger
- Auto and Manual ranging
- Meets Measurement Category 1000 V CAT III and Category IV 600 V safety standards
-
Features
- Electric pump for one handed pressure calibration
- Best in class pressure measurement uncertainty of 0.025 %
- Measure and source mA with best in class 0.015 % accuracy
- Precision pressure adjust vernier
- Variable release rate bleed valve for easy pressure adjustment
- Ideal performance for high accuracy transmitter calibration
- 30 PSI and 100 PSI pressure ranges
- Programmable pump limit: - Eliminates over-pressurization - Allows the user to program target pressures for pumping
- Extended measurement range with any of twenty-nine (29) 700Pxx Pressure Modules
- Source mA with simultaneous pressure measurement to
- test valves and I/Ps
- Simulate mA signals to troubleshoot 4-20 mA loops
- Test pressure switches with built in switch test function
- Power transmitters during test using 24 V loop supply
- Proven cleanout ports reduce pump failures
-
Features
- Has compact, convenient single-use design that requires no downloads
- Includes standard USB connector that needs no special reading device
- Creates PDF and CSV reports with F/C readings automatically
- Scales reported data automatically to graphs for easy visualization
- Features peel-away barcode with trip number for fuss-free traceability
- Comes in sealed, waterproof plastic envelope
-
Features
- Ideal for use in the food sector
- TopSafe: dishwasher-safe protective cover (IP67), protects from dirt and impact
- Small, handy and always ready to hand
- Audible and optical alarm
- Automatic final value recognition (Auto-hold)
- Hardly visible punctures
- Certified according to EN 13485 (only in combination with TopSafe)
-
Features
- Measurement independent of oil type, age and temperature - indicates margin to oil saturation
- In-line process checking through ball valve, no need to drain the oil
- Rugged and reliable construction
- Multi-probe operation; dewpoint and CO2 probes can also be connected
- Vaisala HUMICAP Sensor - proven field performance since 1973
-
Features
- Two optional sampling methods: diffusion or pump aspiration
- User-friendly meter with multilingual user interface
- Numerical and graphical display of measurements
- Data can be logged and transferred to PC via MI70 Link software
- Multiprobe operation: Vaisala’s relative humidity and dew point probes can be used simultaneously with CO2 measurement
-
Features
- The first transmitter that monitors both dew point and process pressure
- A simple and convenient transmitter for monitoring of compressed air
- Highly accurate humidity information thanks to dew point data coupled with live pressure input
- Compatible with the Vaisala Hand-Held DM70 for easy spot-checking, local display and data logging
- Pressure: 1 … 12 bar
- Dew point: -70 … +30 °C (-94 ... +86 °F)
- Digital output RS-485 with MODBUS
-
Features
- Measures dew point from -70 ... +80 °C (-94 ... +176 °F) with an accuracy of ±2 °C (±3.6 °F)
- Condensation-resistant
- Unique auto-calibration feature maintains accuracy over long term
- Compatible with Vaisala DRYCAP Handheld Dew Point Meter DM70
- Traceable calibration to measurements and analog outputs (certificates included)
- Graphical display and keypad for convenient operation
- Optional alarm relays and mains power supply module
- Up to three analog outputs, RS-232/485, LAN
- Modbus protocol support (RTU/ TCP)
-
Features
- Dew point measurement range −70 … +80 °C (−94 … +176 °F) Td/f
- Dew point measurement accuracy up to ±2 °C (±3.6 °F) Td/f
- Operating pressure of probe head 0 … 4 MPa (0 … 40 bar)
- Adjustable installation depth
- Tolerates condensation, oils, dust, and most chemicals
- Sensor purge provides superior chemical resistance
- Modbus RTU over RS-485
- Compatible with Indigo transmitters and Insight PC software
- Traceable calibration certificate
-
Features
- Dew point measurement range −70 … +80 °C (−94 … +176 °F) Td/f
- Dew point measurement accuracy up to ±2 °C (±3.6 °F) Td/f
- Sensor purge provides superior chemical resistance
- Tolerates condensation, oils, dust, and most chemicals
- Modbus RTU over RS-485
- Compatible with Indigo transmitters and Insight PC software
- Traceable calibration certificate
-
Features
- Measures humidity at high temperatures up to +350 °C (+662 °F)
- Dew point measurement range −25 … +100 °C (−13 … +212 °F) Td/f
- Dew point measurement accuracy up to ±2 °C (±3.6 °F) Td/f
- Sensor purge provides superior chemical resistance
- Condensation-tolerant Modbus RTU over RS-485
- Compatible with Indigo transmitters and Insight PC software
- Traceable calibration certificate
-
Features
- Measures humidity at temperatures up to +180 °C (+356 °F)
- Dew point measurement range−40 … +100 °C (−40 … +212 °F) Td/f
- Dew point measurement accuracy up to ±2 °C (±3.6 °F) Td/f
- Sensor purge provides superior chemical resistance
- Condensation-tolerant
- Modbus RTU over RS-485
- Compatible with Indigo transmitters and Insight PC software
- Traceable calibration certificate
-
Features
- Intrinsically safe (Exi) for operation in up to Zone 0 / 20
- Measures RH and T and outputs an extensive range of calculated parameters: for a full list, see Technical data (page 5).
- Designed for harsh conditions
- Temperature range between −70 … +180 °C (−94 … +356 °F) depending on the probe option
- Vaisala HUMICAP sensor features high accuracy, excellent long-term stability, and negligible hysteresis
- Display options: graphical LCD display and non-display model
- Traceable calibration (certificate included)
- Compatible with Vaisala Insight PC software
-
Features
-
Six models for demanding industrial applications
-
Full 0 ... 100 %RH measurement, wide temperature range -40...+180 °C (-40...+356 °F)
-
Pressure tolerance up to 100 bar
-
Excellent performance in harsh conditions; good chemical tolerance
-
Corrosion-resistant IP65/IP66 housing
-
5-point calibration (certificate included)
-
Two analog outputs, calibrated (certificate included)
-
RS232, ASCII output
-
-
Features
- Miniature probe head with low thermal mass for superior response time
- RH accuracy up to 0.8 %RH
- Temperature accuracy up to 0.1 °C (0.18 °F)
- Temperature measurement range −40 … +120 °C (−40 … +248 °F)
- Sensor purge provides superior chemical resistance
- Modbus RTU over RS-485
- Compatible with Indigo transmitters and Insight PC software
- Traceable calibration certificate: 6 points for humidity, 1 point for temperature
- M10×1.5 cable gland included for mounting the probe head
-
Features
- RH accuracy up to 0.8 %RH, Temperature accuracy up to 0.1 °C (0.18 °F)
- Temperature measurement range -70 ... +180 °C (-94 ... +356 °F)
- Vapor and pressure proof construction
- Probe and sensor warming functions minimize condensation on probe
- Sensor purge provides superior chemical resistance
- Plug & play compatible with Indigo series of transmitters
- Modbus RTU over RS-485
- Traceable calibration certificate: 6 points for humidity, 1 point for temperature
-
Features
- RH accuracy up to 0.8 %RH, Temperature accuracy up to 0.1 °C (0.18 °F)
- Temperature measurement range -70 ... +180 °C (-94 ... +356 °F)
- 250 mm (9.84 in) probe allows easy process installation through insulation
- Sensor purge provides superior chemical resistance
- Modbus RTU over RS-485
- Plug & play compatible with Indigo series of transmitters
- Traceable calibration certificate: 5 points for humidity, 1 point for temperature
- Sintered AISI316L filter standard in delivery
-
Features
- RH accuracy up to 0.8 %RH, Temperature accuracy up to 0.1 °C (0.18 °F)
- Temperature measurement range -70 ... +180 °C (-94 ... +356 °F)
- Operating pressure 0 ... 10 MPa (0 ... 100 bar)
- Sensor purge provides superior chemical resistance
- Modbus RTU over RS-485
- Plug & play compatible with Indigo series of transmitters
- Traceable calibration certificate: 5 points for humidity, 1 point for temperature
-
Features
- Compact size
- RH accuracy up to ±1.0 %RH
- Temperature accuracy up to ±0.2 °C (0.36 °F)
- Temperature measurement range −40 … +60 °C (−40 … +140 °F)
- Chemical purge provides superior chemical resistance
- Modbus RTU over RS-485
- Compatible with Indigo series transmitters and Insight PC software
- Traceable calibration certificate: 6 points for humidity, 1 point for temperature
-
Features
- Designed for industrial spot checking and field calibration
- Three models: accurate measurement ranges from −60 to +60 °C (−76 ... +140 °F)
- Vaisala DRYCAPâ sensor with unique auto calibration function
- Sensor withstands condensation
- Data can be logged and transferred to a PC via MI70 Link software
- Traceable calibration (certificate included)
- Fast response, enhanced by sensor purge option
- Variety of sampling cell options for connection to pressurized processes
-
Features
- Adjustable angle of 30/ 60 / 90 Degree
- Alarm beef sound at the high or low temperature limit
- Presentable maximum / minimum temperature limit
- 213mm stainless steel sensor probe
- Temperature unit F/ C degree
- 1 sec. normal temperature sensing time
- One hour auto shut off
- Protect plastic sleeve with clip for stainless steel