- IP 67 waterproof & dustproof protection, completely sealed for use in harsh environments
- Designed to withstand 3 meter drop (with holster)
- Unique function for accurate
-
Features
- Digital multimeter designed specifically for HVAC professionals
- Includes built-in thermometer to measure temperature from -40°C to 400°C (-40°F to 752°F)
- Provides microamps to test flame sensors
- Features low input impedance to helps prevent false readings due to ghost voltage
- Presents a large white LED backlight for working in poorly lit areas
-
Best-selling ST-50 series hygro-thermograph recorder equipped with an electronic sensor. Features
- Important measurement records can be backed up in CSV format.
- Up to 6 months record on chart paper
- Data can be saved to a memory card (SD card)
- Long term recording
- Long-term stability, wide range measurement
- Sensor cable extension
-
Features
- Zone Display - clearly indicates the food is out of safe zone (4 to 60°C)above/below
- 2 in 1 design - Infrared + Foldable Thermocouple Probe
- IP65 Protection
- Bright white LED as pointer
- Ultra thin design
- Max/Min and Lock modes
- Retractable probe
- Dual display
- Auto power off
- Adjustable emissivity
-
Features
- Compact, single-use temperature logger
- Shadow Log guarantees trip data
- No software required for download
- Built-in USB connector, no special reading device needed
- On-board software automatically creates PDF and CSV reports in °F and °C
- View reports on a PC or tablet
- Recorded data automatically scaled to graph
-
Features
- New 2 part document for ease of use
- New improved pull tab designed to make it easier to START
- Dual scale °F/°C chart
- Bilingual operation instructions
- Various models ranging from 5-Day to 90-Day transit periods
- Available in three temperature ranges
- Patented design guarantees recording trace stops at end of trip
- Vented case for superior air circulation and faster temperature response
- Serial number on each unit for traceability
-
Features
- T1-T2 function
- Temperature alarm function
- Data hold function
- Adjustable auto power off timer
- Fast response with high accuracy
- Measures K, J, E, T type of thermocouples
- Min/Max/Avg recording of all channels
- USB interface, PC software included
- HOLD Function
- Datalogging up to 32,000 points each channel
- Large backlit LCD shows all channels on display
-
Features
- 4 data loggers for monitoring Chilled Goods, Frozen Goods, Ripening Goods and Ambient Pharmaceutical
- Custom cumulative alarm versions of each logger available if required.
- No set-up required. One button press-to-start logging
- Pre-configured with appropriate sample rates, alarm thresholds and cumulative alarms for each application
- No software required. Result appear in an automatically generated PDF file
-
Features
- 4 data loggers for monitoring Chilled Goods, Frozen Goods, Ripening Goods and Ambient Pharmaceutical
- Custom cumulative alarm versions of each logger available if required.
- No set-up required. One button press-to-start logging
- Pre-configured with appropriate sample rates, alarm thresholds and cumulative alarms for each application
- No software required. Result appear in an automatically generated PDF file
-
Features
- 4 data loggers for monitoring Chilled Goods, Frozen Goods, Ripening Goods and Ambient Pharmaceutical
- Custom cumulative alarm versions of each logger available if required.
- No set-up required. One button press-to-start logging
- Pre-configured with appropriate sample rates, alarm thresholds and cumulative alarms for each application
- No software required. Result appear in an automatically generated PDF file
-
Features
- 4 data loggers for monitoring Chilled Goods, Frozen Goods, Ripening Goods and Ambient Pharmaceutical
- Custom cumulative alarm versions of each logger available if required.
- No set-up required. One button press-to-start logging
- Pre-configured with appropriate sample rates, alarm thresholds and cumulative alarms for each application
- No software required. Result appear in an automatically generated PDF file
-
Features • -18 to +55°C (-0.4 to +131°F) temperature measurement range • Stores over 1,000,000 readings (As per spec table) • No software to install - configure using your normal web browser • Use with a PC or Mac • Display shows current, maximum and minimum readings • Status and alarm indicators • On-board alarm sounder • Data can be uploaded to the EasyLog Cloud
-
Features
- Measure and Record Temperature -18°C to 55°C Using Internal Sensor with ±0.2°C
- Logs over 1 Million Temperature Readings onto non-Volatile Internal Memory
- LCD Display Shows Current Temperature Readings, Min and Max Readings, Battery Level and Alarm Status
- No Software to Download, Simply Configure Using Browser, Recorded Readings Stored to EasyLog Cloud for Viewing on Any Device or Browser
- Includes (2) AAA Alkaline Batteries, Mounting Bracket and USB Cable
-
Features
- Measures temperature range of -40°C to +125°C (-40°F to +257°F)
- Dual channel recording through two external thermistor probes
- Wirelessly stream and view data via WIFI on PCor FilesThruThaAir Cloud
- Easy sensor set-up using free PC software application
- View and analyze multiple sensors, including graphing of historic data
- Configurable high and low alarms with indicator
- Sensor memory stores all data even if WIFI is temporarily disconnected
-
Features
- Measures temperature range of -200°C to +1350°C (-328°F to +2465°F) (probe dependent)
- Dual channel recording through two external thermocouple probes
- Wirelessly stream and view data via WIFI on PCor FilesThruThaAir Cloud
- Easy sensor set-up using free PC software application
- View and analyze multiple sensors, including graphing of historic data
- Configurable high and low alarms with indicator
-
Features
- Temperature measurement range -20 to +60°C (-4 to +140°F)
- Wirelessly stream and view data via WIFI on PCor FilesThruThaAir Cloud
- Easy sensor set-up using free PC software application
- View and analyse multiple sensors, including graphing of historic data
- Configurable high and low alarms with indicator
- Sensor memory stores all data even if WIFI is temporarily disconnected
-
Features
- Thermistor probe temperature measurement range -40 to +125°C (-40 to +257°F)
- Wirelessly stream and view data via WIFI on PCor FilesThruThaAir Cloud
- Easy sensor set-up using free PC software application
- View and analyze multiple sensors, including graphing of historic data
- Configurable high and low alarms with indicator
- Sensor memory stores all data even if WIFI is temporarily disconnected
-
- Thermistor probe temperature measurement range -40 to +125°C (-40 to +257°F)
- Wirelessly stream and view data via WIFI on PCor FilesThruThaAir Cloud
- Easy sensor set-up using free PC software application
- View and analyse multiple sensors, including graphing of historic data
- Configurable high and low alarms with indicator
- Sensor memory stores all data even if WIFI is temporarily disconnected
-
Features
- measurement range -40 to +125°C (-40 to +257°F)
- Stores over 250,000 readings
- Logging rates between 2 seconds and 1 hour
- On screen menu and graphing to start, stop, review and restart the logger in the field
- Triggered logging mode to start recording data once a user defined level is met
- User-programmable audible alarm thresholds with highly visible confidence/alarm LEDs
-
Features
- Measures temperature range of -40°C to +125°C (-40°F to +257°F)Lascar
- Stores over 250,000 readings
- Logging rates between 2 seconds and 1 hour
- On screen menu and graphing to start, stop, review and restart the logger in the field
- Triggered logging mode to start recording data once a user defined level is met
- High contrast, greyscale, backlit, graphic LCD screen to denote status and alarm level
- User-programmable audible alarm thresholds with highly visible confidence/alarm LEDs
- EasyLog software available as a free download
-
Features
- Compatible with K, J and T-type with miniature thermocouple plug connection
- Stores over 250,000 readings
- EasyLog software available as a free download
- Logging rates between 2 seconds and 1 hour
- Supplied with 1.5m K-type thermocouple with 0 to 200°C (32 to 392°F)
- Immediate, delayed, push-button or temperature triggered start mode
-
Features
- Compatible with K, J and T-type with miniature thermocouple plug connection
- Stores over 250,000 readings
- EasyLog software available as a free download
- Logging rates between 2 seconds and 1 hour
- Supplied with 1.5m K-type thermocouple with 0 to 200°C (32 to 392°F)
- Immediate, delayed, push-button or temperature triggered start mode
-
Features
- -30 to 80°C (-22 to +176°F) measurement range
- Stores over 250,000 readings
- Logging rates between 10 seconds and 1 hour
- On screen menu and graphing to start, stop, review and restart the logger in the field
- Triggered logging mode to start recording data once a user defined level is met
- User-programmable audible alarm thresholds with highly visible confidence/alarm LEDs
-
Features
- 3 data loggers for monitoring Chilled Goods, Frozen Goods and Ripening Goods
- No set-up required. One button press-to-start logging
- Pre-configured with appropriate sample rates and alarm thresholds for each application
- Reusable with 12+ months battery life
- Various export options including PDF, Microsoft Excel and JPEG
-
Features
- 3 data loggers for monitoring Chilled Goods, Frozen Goods and Ripening Goods
- No set-up required. One button press-to-start logging
- Pre-configured with appropriate sample rates and alarm thresholds for each application
- Reusable with 12+ months battery life
- Various export options including PDF, Microsoft Excel and JPEG
-
Features
- 3 data loggers for monitoring Chilled Goods, Frozen Goods and Ripening Goods
- No set-up required. One button press-to-start logging
- Pre-configured with appropriate sample rates and alarm thresholds for each application
- Reusable with 12+ months battery life
- Various export options including PDF, Microsoft Excel and JPEG
-
Features
- Compatible with K, J and T-tyoe thermocouple with miniature thermocouple plug connection
- Stores over 32,000 readings
- Logging rates between 1 second and 12 hours
- Immediate and delayed logging start
- EasyLog software available as a free download
- Supplied with 1.5m K-type thermocouple probe with 0 to 200°C (32 to 392°F) measurement range
-
Features
- Compatible with K, J and T-type thermocouple with miniature thermocouple plug connection
- Stores over 32,000 readings
- Logging rates between 1 second and 12 hours
- Immediate and delayed logging start
- EasyLog software available as a free download
- Supplied with 1.5m K-type thermocouple probe with 0 to 200°C (32 to 392°F) measurement range
-
Features
- Stainless Steel Sensor
- Nominal pressure: 0 ...4 mH2O up to 0...200 mH2O
- Accuracy: 0.1 % FSO
- Diameter 35 mm
- Cable and sensor section detachable
- Thermal error in compensated range -20...70°C: 0.2 FSO TC 0.02% FSO/10K 0,02 % FSO / 10K
- High Accuracy
- Communication connection
- turn-down 1:10
- IS-version (Ex ia = intrinsically safe for gases and dusts)
- SIL 2 application according to IEC 61508 / IEC 61511
- Different electrical connections
- Customer specific versions e.g. special pressure range
- Mechanical and Plant Engineering
- Energy Industry
- Environmental Industry
-
Features
- Stainless Steel Sensor
- Nominal pressure: 0 ... 400 mbar up to 0 ... 40 bar
- Accuracy: 0.1 % FSO
- Thermal error in compensated range -20 … 80 °C: 0.2 % FSO TC 0.02 % FSO / 10 K
- Turn-down 1:10
- Communication interface for adjusting of offset, span and damping
- IS-version (Ex ia = intrinsically safe for gases and dusts)
- Adjustment of nominal pressure gauges (factory-provided)
- Chemical Industry
- Environmental Industry
-
Features
- Nominal pressure: 0 ... 400 mbar up to 0 ... 60 bar
- Accuracy: 0.5 % FSO
- Pressure port G 3/4" flush
- Ceramic Sensor, Plant And Mechanical Engineering
- IS-version (only for 4... 20 mA / 2-wire): Ex ia = intrinsically safe for gases and dusts
- SIL 2 application according to IEC 61508 / IEC 61511
- Pressure port PVDF for aggressive media
- Different electrical and mechanical connections
- Customer specific versions
- Mechanical and Plant Engineering
- Energy Industry
- Medical Technology
- Environmental Industry
-
Features
- Nominal pressure: 0 ... 40 mbar up to 0 ... 20 bar
- Accuracy: 0.35 % (opt. 0.25 %) FSO
- Pressure port G 1 1/2" for pasty and polluted media
- Ceramic Sensor
- IS-version (Ex ia = intrinsically for gases and dusts)
- Pressure port PVDF for aggressive media
- Diaphragm pure ceramic (99,9 % Al2O3)
- Customer specific versions
- Mechanical and plant engineering
- Laboratory
- Environmental Industry
-
Features
- Stainless Steel Sensor
- Nominal pressure: 0 ... 1 mH2O up to 0 ... 100 mH2O
- Accuracy: 0.35 % (opt. 0.25 %) FSO
- Diameter 35 mm
- Cable and sensor section detachable
- Excellent linearity
- Small thermal effect
- Integrated lightning protection and increased over voltage protection; 8 kA gas discharge tube (8/20 μsec); 4 kV surge l-l/l-e according to EN61000-4-5
- SIL 2 (safety integrity level) according to IEC 61508 / 61511
- different kinds of cable and elastomeres
- customer specific versions e.g. special pressure ranges
- Energy Industry
- Environmental Industry
-
Features
- Stainless Steel Sensor
- Nominal pressure range from 0 ... 1 mH2O up to 0 ... 250 mH2O
- Accuracy: 0.35 % (opt. 0.25% / 0.1 %) FSO
- Diameter 35 mm
- Cable and sensor section detachable
- Excellent long term stability
- High accuracy
- IS-version (Ex ia = intrinsically safe for gas and dust)
- SIL 2 (Safety integrity level)
- Customer specific versions
- Mounting accessories as cable gland and terminal clamp of stainless steel
- Different kinds of cables
- Different kinds of seal materials
- Energy Industry
- Environmental Industry
-
Features
- Stainless Steel Sensor
- Nominal pressure range from 0 ... 4 mH2O up to 0 ... 200 mH2O
- Accuracy: 0.1 % FSO
- Diameter 35 mm
- Cable and sensor section detachable
- Thermal error in compensated range -20...70°C: 0.2 FSO TC 0.02% FSO/10K 0,02 % FSO / 10K
- High accuracy
- Communication connection
- Turn-down 1:10
- IS-version (Ex ia = intrinsically safe for gas and dust)
- Mounting accessories as cable gland and terminal clamp in stainless steel
- Different kinds of cables
- Different kinds of seal materials
- Energy Industry
- Environmental Industry
-
Features
- Nominal pressure: 0 ... 1 mH2O up to 0 ... 250 mH2O
- Nominal temperature from 0 ... 30 °C up to 0 ... 70 °C
- Accuracy: 0.35 % (opt. 0.25 %) FSO
- Diameter 26.5 mm
- Separate output signals for pressure and temperature ranges
- Easy handling
- low maintenance and wiring costs
- Drinking water certificate acc. to DVGW and KTW
- Different kinds of cables
- Different kinds of elastomers
- Customer specific versions
- Energy Industry
- Environmental Industry
-
Features
- Nominal pressure: 0 ... 4 mH2O up to 0 ... 200 mH2O
- Accuracy: 0,1 % FSO
- Diameter 26,5 mm
- Small thermal effect
- Excellent accuracy
- Excellent long term stability
- IS-version (Ex ia = intrinsically safe for gas and dust)
- Drinking water certificate according to DVGW and KTW
- Different kinds of cables
- Different kinds of seal materials
- Energy Industry
- Oil and Gas Industry
- Environmental Industry
-
Features
- Stainless Steel Sensor
- Nominal pressure: 0 ... 1 mH2O up to 0 ... 250 mH2O
- Accuracy: 0.35 % (opt. 0.25 %) FSO
- Diameter 19 mm for cramped areas e.g. 1" observation well
- Small thermal effect
- Excellent linearity
- Excellent long term stability
- Different kinds of cable
- Customer specific versions e.g. special pressure ranges
- Energy Industry
- Environmental Industry
-
Features
- Ceramic Sensor
- Nominal pressure: 0 ... 40 cmH2O up to 0 ... 100 mH2O
- Accuracy: 0.35 % (opt. 0.25 %) FSO
- Diameter 45 mm
- Cable and sensor section detachable
- Chemical resistance
- Housing PP-HT
- Integrated lightning protection and increased overvoltage protection; 8 kA gas discharge tube (8/20 μsec); 4 kV surge l-l/l-e according to EN61000-4-5
- Cable protection (on request)
- Diaphragm pure ceramic (99,9 % AI2O3)
- Different kinds of cables
- Different kinds of elastomeres
- Chemical Industry
- Environmental Industry
-
Features
- High Purity Ceramic Sensor
- Nominal pressure: 0 ... 40 cmH2O up to 0 ... 100 mH2O
- Accuracy: 0.35 % (opt. 0.25 %) FSO
- Diameter 45 mm
- Chemical resistance
- High over pressure capability
- Pure ceramic sensor
- Especially for tank level measurement of viscous and aggressive media
- Housing material PP-HT or PVDF
- Diaphragm ceramics Al2O3 (99.9 %)
- Different kinds of cable and seal materials
- Prepared for mounting with pipe
- Chemical Industry
- Environmental Industry
-
Features
- Ceramic Sensor
- Nominal pressure: 0 ... 1 mH2O up to 0 ... 100 mH2O
- Accuracy: 0.35 % (opt. 0.25 %) FSO
- Diameter 35mm
- Diaphragm ceramics Al2O3 (99.9 %)
- Cable and sensor section detachable
- Excellent long term stability
- Integrated lightning protection 8 kA gas discharge tube (8/20µsec); 4 kV surge l-l/l-e according to EN61000-4-5
- Mounting accessories
- Different kinds of elastomer
- Customer specific versions e. g. special pressure ranges
- Chemical Industry
- Environmental Industry
-
Features
- Nominal pressure: 0 ... 4 mH2O up to 0 ... 100 mH2O
- Accuracy: 0.5 % FSO
- Diameter 35 mm
- Excellent long term stability
- Easy handling
- SIL 2 (safety integrity level) according to IEC 61508 / IEC 61511
- Different kinds of cables and elastomeres
- Customer specific version e.g. special pressure ranges
- Chemical Industry
- Environmental Industry
-
Features
- Ceramic Sensor, Flush, Plastic Probe
- Nominal pressure: from 0 ... 6 mH2O up to 0 ... 200 mH2O
- Diameter 21 mm
- Excellent linearity
- Excellent long term stability
- Accuracy: 0,5% FSO
- Suitable for hydrostatic level measurement e.g. 3/4" pipes
- Different cable materials
- Customer specific versions, e.g. special pressure rang
- Chemical Industry
- Environmental Industry
-
Features
- Nominal pressure: 0 ... 60 cmH2O up to 0 ... 200 mH2O
- Accuracy: 0.1 % FSO
- Shipping approvals: American Bureau of Shipping (ABS), Bureau Veritas (BV), China Classification Society (CCS), Det Norske Veritas (DNV), Germanischer Lloyd (GL), Lloyd's Register (LR)
- Diameter 39.5 mm
- HART®-communication (setting of offset,span and damping)
- High overpressure capability
- High long term stability
- IS-version; Ex ia = intrinsically safe for gases and dusts
- Diaphragm 99,9 % AI2O3
- Different housing materials (stainless steel, CuNiFe)
- Screw-in and flange version
- Accessories e.g. assembling and probe flange, mounting clamp
- Marine Industry
- Shipbuilding/ Offshore Industry
-
Features
- Nominal pressure: from 0 ... 40 cmH2O up to 0 ... 200 mH2O
- Diameter 39.5 mm
- LR-certificate (Lloyd´s Register)
- DNV ▪ GL Approval (Det Norske Veritas ▪ Germanischer Lloyd)
- ABS-certificate (American Bureau of Shipping)
- CCS-certificate (China Classification Society)
- High overpressure resistanc
- High long-term stability
- Diaphragm Al2O3 99.9 %
- Different housing materials (stainless steel, CuNiFe)
- IS-version, Ex ia = intrinsically safe for gas
- Screw-in and flange version
- Accessories e.g. assembling and probe flange, mounting clamp
- Water Industry
- Shipbuilding/ Offshore Industry
-
Features
- Nominal pressure: from 0 ... 4 mH2O up to 0 ... 100 mH2O
- Acuracy: 0,35 % FSO
- Diameter 22 mm
- Excellent long term stability
- Highly appropriated for wastewater, sludge and viscous media
- Diaphragm ceramics 99,9% Al2O3 (on request)
- IS-version (in preparation), Ex ia = intrinsically safe for gases and dust
- Mounting with stainless steel tube
- Different kinds of cable
- Different kinds of elastomer
- Chemical Industry
- Energy Industry
- Environmental Industry
-
Features
- Nominal pressure range 0 ... 60 cmH2O up to 0 ... 100 mH2O
- Accuracy: 0.1 %
- Diameter 39.5 mm
- HART®-communication (setting of offset. span and damping)
- Permissible temperatures up to 85 °C
- High long term stability
- IS-version (Ex ia = intrinsically safe for gas and dust)
- Mounting with stainless steel pipe
- Flange version
- Diaphragm 99.9 % AI2O3
- Accessories e.g. transmitter and mounting flanges and terminal clamp
- Water Industry
- Sewage Industry
- fuel and Oil Industry
-
Features
- Nominal pressure range 0 ... 60 cmH2O up to 0 ... 100 mH2O
- Accuracy: 0.1 %
- Diameter 39,5 mm
- Cable and sensor section detachable
- HART®-communication (setting of offset. span and damping)
- Permissible temperatures up to 85 °C
- High long term stability
- IS-version (Ex ia = intrinsically safe for gas and dust)
- Cable protection via corrugated pipe
- Diaphragm (AI2O3 99,9 %)
- Accessories e.g. mounting flange with cable gland and terminal clamp
- Chemical Industry
- Energy Industry
- Environmental Industry
-
Features
- Nominal pressure: 0 ... 40 cmH2O up to 0 ... 100 mH2O
- Accuracy: 0.35 % (opt. 0.25 %) FSO
- Diameter 39.5 mm
- Cable and sensor section detachable
- Ceramic Sensor
- Especially for sewage, viscous and pasty media
- IS-protection (Ex ia = intrinsically safe for gas and dust)
- Cable protection via corrugated pipe
- Diaphragm pure ceramic (99,9 % AI2O3)
- Different kinds of cable
- Different kinds of elastomeres
- Chemical Industry
- Energy Industry
- Environmental Industry
-
Features
- Nominal pressure: from 0 ... 4 mH2O up to 0 ... 250 mH2O
- Nominal temperature from 0 ... 30 °C up to 0 ... 70 °C
- Accuracy: 0,5 % FSO
- Diameter 26,5 mm
- Separate output signals for pressure and temperature ranges
- Excellent accuracy
- Easy handling
- Low maintenance and wiring costs
- Different kinds of cables
- Different kinds of seal materials
- Customer specific versions
- Energy Industry
- Environmental Industry
-
Features
- Supports multi-users and network environments
- Calibration and asset management
- Simple user interface
- Scanning and printing of QR codes
- User definable permissions and access levels
- Support various units
- Can calibrate variety pressure and temperature instruments
- Can calibrate several instruments at a time
- Calibration planning and scheduling
- Certificate management and creation
- Certificate customization
-
Features •Portable, only 3.7 lb • Minimal maintenance • Increase and decrease pressure smoothly • Hand-tight quick connectors Applications The Additel 925 Hydraulic Pressure Test Pump is designed to generate pressure from 85% vacuum to 6000 psi (400 bar) for the application requiring accurate pressure testing and calibration. It can be used in calibrating pressure gauges, transmitters, or other pressure measuring instruments.
-
Features
- Pressure ranges to 60,000 psi (4,200 bar)
- 0.05%FS, 0.1%FS or 0.25%FS accuracy
- Fully temperature compensated accuracy
- IP67
- Data logging and wireless (680W)
- ISO 17025-accredited calibration w/data included
- Precision pressure measurement
- Field gauge calibration
- Pressure safety valve (PSV) testing
- Pressure regulator testing
-
Features
- nominal pressure: 0 ... 400 mbar up to 0 ... 600 bar
- accuracy: 0.5 % FSO
- rotatable and configurable display module
- indication of measured values on a 4-digit LED display
- 1 or 2 independent PNP contacts, freely configurable
- IS-version Ex ia = itrinsically safe for gases
- pressure port PVDF
- customer specific versions
- Mechanical and plant engineering mechanical and plant engineering
- Environmental industry environmental industry
-
Features
- Nominal pressure: 0 ... 100 mbar up to 0 ... 40 bar
- Accuracy: 0.35 % (opt. 0.25 %) FSO
- 1 or 2 independent PNP contacts, freely configurable
- Indication of measured values on a 4-digit LED display
- Rotatable and configurable display module
- Hygienic process connections with flush stainless steel diaphragm
- Configurable contacts (switch on / switch off points, hysteresis / window mode, switch on / switch off delay)
- IS-version - Ex ia = intrinsically safe for gases
- Analog Output - 2-wire: 4 ... 20 mA, 3-wire: 4 ... 20 mA with Turn Down 1:5, 0 ... 10
- Customer Specific Versions
- Medical Technology
- Food and Beverage
-
Features
- Nominal pressure: 0 ... 100 mbar up to 0 ... 600 bar
- Accuracy: 0.35 % (opt. 0.25 %) FSO
- Indication of measured values on a 4-digit LED display
- Rotatable and configurable display module
- 1 or 2 independent PNP contacts, freely configurable
- IS-version - Ex ia = intrinsically safe for gases and dust
- Pressure sensor welded
- Customer Specific Versions
- Mechanical and plant engineering
- HVAC
- Environmental industry
-
Features
- Nominal pressure: 0 ... 100 mbar up to 0 ... 600 bar
- Accuracy: 0,35 % FSO
- Analog output (optional): 4 ... 20 mA or 0 ... 10 V
- Indication of measured values on a 4-digit LED display
- Parametrization by IO-Link or set menu system (VDMA-conform)
- Rotatable and configurable display
- 2 contacts
- different mechanical connections
- customer specific versions
- Mechanical and Plant Engineering
- Hydraulics
- Packaging and Paper Industry
-
Features
- Nominal pressure: 0 ... 6 mbar up to 0 ... 1000 mbar
- Accuracy: 0,35 % FSO
- Aluminum housing
- Rotatable and configurable display module
- 4-digit LED display
- Suited for non-aggressive gases and compressed air
- 1 / 2 PNP contacts
- customer specific versions
- Mechanical and plant engineering
- HVAC
-
Features
- Nominal pressure: 0 ... 6 bar up to 0 ... 600 bar
- Accuracy: 0.5 % FSO
- 1 analog output and up to 2 contacts
- Display and housing rotatable
- Perfect for oxygen applications
- Mechanical and Plant Engineering
- Energy Industry
- Refrigeration Engineering
- Medical Technology
- Utility Vehicles / Mobile Hydraulics
-
Features
- Nominal pressure: 0 ... 600 bar up to 0 ... 2200 bar
- Accuracy: 0,35 % FSO
- Indication of measured values on a 4-digit LED display
- Rotatable and configurable display module
- 1, 2 or 4 independent PNP contacts, freely configurable
- Pressure sensor welded
- Extremely robust and excellent longterm stability
- Adjustability of span and offset (4 ... 20 mA / 3-wire)
- Customer specific versions
- Mechanical and Plant Engineering
- Utility Vehicles / Mobile Hydraulics
-
Features
- Nominal pressure: 0 ... 10 mbar up to 0 ... 1000 mbar
- Accuracy: 0.35 % FSO
- Indication of measured values on a 4-digit LED display
- Rotatable and configurable display module
- 1, 2 or 4 independent PNP contacts, freely configurable
- IS-version: Ex ia = intrinsically safe for gases
- Customer specific versions
- Mechanical and Plant Engineering
- HVAC
- Laboratory
-
Features
- Nominal pressure: 0 ... 6 bar up to 0 ... 600 bar
- Accuracy: 0.5 % FSO
- Indication of measured values on a 4-digit LED display
- Rotatable and configurable display module
- 1, 2 or 4 independent PNP contacts, freely configurable
- IS-version: Ex ia = intrinsically safe for gases
- Oxygen application
- Customer specific versions
- Mechanical and Plant engineering
- Energy Industry
- Refrigeration Engineering
- Medical Technology
- Utility Vehicles / Mobile Hydraulics
-
Features
- Nominal pressure: 0 ... 60 bar up to 0 ... 400 bar
- Accuracy: 0.5 % FSO
- 1, 2 or 4 independent PNP contacts, freely configurable
- Rotatable and configurable display module
- Indication of measured values on a 4-digit LED display
- IS-version - Ex ia = intrinsically safe for gases
- Cooling element up to 300°C
- Customer specific versions
- Mechanical and Plant Engineering
- Food and Beverage
-
Features
- Nominal pressure: 0 ... 400 mbar up to 0 ... 600 bar
- Accuracy: 0.5 % FSO
- Indication of measured values on a 4-digit LED display
- Rotatable and configurable display module
- 1, 2 or 4 independent PNP contacts, freely configurable
- IS-version: Ex ia = intrinsically safe for gases
- Pressure port PVDF
- Customer specific versions
- Mechanical and Plant Engineering
- Environmental Industry
-
Features
- Nominal pressure: 0 ... 100 mbar up to 0 ... 40 bar
- Accuracy: 0.35 % (opt. 0.25 %) FSO
- Rotatable and configurable display module
- Indication of measured values on a 4-digit LED display
- 1, 2 or 4 independent PNP contacts, freely configurable
- Configurable contacts (switch on / switch off points, hysteresis / window mode, switch on / switch off delay)
- IS-version : Ex ia = intrinsically safe for gases
- Customer specific versions
- Analogue output
- Medical Technology
- Food and Beverage