Loading...
  • Features
    • Measurement range -100 to +100°C (-148 to +212°F)
    • T-type probe on 1m cable
    • Dual channel recording through two external thermocouple probes
    • Wirelessly stream and view data on the EasyLog Cloud, App or on a PC
    • View and analyze multiple sensors, including graphing of historic data
    • Configurable high and low alarms with indicator
    • Easy sensor set-up using free PC software or App
  • Features
    • Measurement range -100 to +100°C (-148 to +212°F)
    • High accuracy T-type probe on 2m cable
    • Dual channel recording through two external thermocouple probes
    • Wirelessly stream and view data on the EasyLog Cloud, App or on a PC
    • View and analyze multiple sensors, including graphing of historic data
    • Configurable high and low alarms with indicator
    • Easy sensor set-up using free PC software or App
  • Features
    • Temperature measurement range -20 to +60°C (-4 to +140°F)
    • Wirelessly stream and view data via WIFI on PCor FilesThruThaAir Cloud
    • Easy sensor set-up using free PC software application
    • View and analyse multiple sensors, including graphing of historic data
    • Configurable high and low alarms with indicator
    • Sensor memory stores all data even if WIFI is temporarily disconnected
     
  • Features • High Accuracy temperature -20 to +60°C (-4 to +140°F) • Wirelessly stream and view data on the EasyLog Cloud, App or on a PC • Easy sensor set-up using free PC software application • View and analyse multiple sensors, including graphing of historic data • Configurable high and low alarms with indicator • Sensor memory stores all data even if WiFi is temporarily disconnected
  • Features
    • 20 to 60°C (-4 to +140°F) temperature and 0 to 100% humidity measurement range
    • Wirelessly stream and view data via WIFI on PCor FilesThruThaAir Cloud
    • Easy sensor set-up using free PC software application
    • View and analyze multiple sensors, including graphing of historic data
    • Configurable high and low alarms with indicator
    • Sensor memory stores all data even if WIFI is temporarily disconnected
     
  • Features
    • 20 to 60°C (-4 to +140°F) temperature and 0 to 100% humidity measurement range
    • Wirelessly stream and view data via WIFI on PCor FilesThruThaAir Cloud
    • Easy sensor set-up using free PC software application
    • View and analyze multiple sensors, including graphing of historic data
    • Configurable high and low alarms with indicator
    • Sensor memory stores all data even if WIFI is temporarily disconnected
     
    • Thermistor probe temperature measurement range -40 to +125°C (-40 to +257°F)
    • Wirelessly stream and view data via WIFI on PCor FilesThruThaAir Cloud
    • Easy sensor set-up using free PC software application
    • View and analyse multiple sensors, including graphing of historic data
    • Configurable high and low alarms with indicator
    • Sensor memory stores all data even if WIFI is temporarily disconnected
     
  • Features
    • Thermistor probe temperature measurement range -40 to +125°C (-40 to +257°F)
    • Wirelessly stream and view data via WIFI on PCor FilesThruThaAir Cloud
    • Easy sensor set-up using free PC software application
    • View and analyze multiple sensors, including graphing of historic data
    • Configurable high and low alarms with indicator
    • Sensor memory stores all data even if WIFI is temporarily disconnected
     
  • Features
    • Remove the need for physical data retrieval and logger set up with the EL-WIFI
    • Allows remote data collection over a WiFi
    • Users can also set up e-mail alerts which will notify them as an alarm event happens
     
  • Features • Temperature measurement range -40 to +125 °C (-40 to +257 °F) • Configurable alarm levels with on-board warning light and sounder • Digital calibratable probe with 3m cable (calibration certificate can be ordered separately) • No need to remove from service for recalibration, just replace the probe • Wirelessly stream and view data on the EasyLog Cloud, and configure alarm email notifications • View and analyse multiple devices, including graphing of historic data • Easy device setup using free PC software or mobile app • Device memory stores all data even if Wi-Fi is temporarily disconnected
  • Features
    • Measurement range -100 to +100°C (-148 to +212°F)
    • T-type probe on 1m cable
    • Wirelessly stream and view data on the EasyLog Cloud, App or on a PC
    • View and analyse multiple sensors, including graphing of historic data
    • Configurable high and low alarms with indicator
    • Easy sensor set-up using free PC software or App
  • Features
    • -Measurement range -100 to +100°C (-148 to +212°F)
    • High accuracy T-type probe on 2m cable
    • Wirelessly stream and view data on the EasyLog Cloud, App or on a PC
    • View and analyse multiple sensors, including graphing of historic data
    • Configurable high and low alarms with indicator
    • Easy sensor set-up using free PC software or App
  • Features
    • WiFi datalogger with external thermistor probe in a glycol bottle to mimic a vaccine
    • Temperature measurement range -40 to +60°C (-40 to +140°F)
    • Wirelessly stream and view temperature data on the EasyLog Cloud, App or on a PC
    • Easy sensor set-up using free PC software application
    • Configurable high and low alarms with indicator
    • Sensor memory stores all data even if WiFi is temporarily disconnected
    • Calibration certificate supplied at 2 and 8°C
  • Features
    • Dual channel WiFi datalogger with two external thermistor probes in glycol bottles to mimic vaccines
    • Temperature measurement range -40 to +60°C (-40 to +140°F)
    • Wirelessly stream and view temperature data on the EasyLog Cloud, App or on a PC
    • Easy sensor set-up using free PC software application
    • Configurable high and low alarms with indicator
    • Sensor memory stores all data even if WiFi is temporarily disconnected
    • Calibration certificate supplied at 2 and 8°C
  • Features
    • Temperature measurement range -40 to +60 °C (-40 to +140 °F)]
    • Configurable alarm levels with on-board warning light and sounder
    • Digital calibratable probe with 3m cable
    • No need to remove from service for recalibration, just replace the probe
    • Wirelessly stream and view data on the EasyLog Cloud, and configure alarm email notifications
    • View and analyze multiple devices, including graphing of historic data
    • Easy device setup using free PC software or mobile app
    • Device memory stores all data even if Wi-Fi is temporarily disconnected
    • Traceable calibration certificate supplied at 2°C and 8°C
  • Features
    • Portable system for dosimetry control with standalone power supply
    • Monitoring and evaluation of radiation exposure of the staff
    • Protected performance for use in the field environment
  • Features
    • Scintillator-based detectors with a silicon photomultiplier
    • Ability to store data in non-volatile memory
    • Sound, light, and vibration alarms of threshold levels exceeding
    • Infrared port for transferring the dose accumulation history and event history from the dosimeter to the personal computer, as well as for setting up the dosimeter
    • Glass-filled plastic shock-resistant housing of high ingress protection rating IP67
    • Backlight of the digital display
    • Resistant to 60 repetitive shocks, each corresponding to a drop of 10 cm on a hard steel surface, and resistant to 6 drops (one drop on each side) from a height of 1 m on a hard surface
  • Features
    • Precise Measurement : Utilizes a unique Venturi tube structure
    • 2″ LCD Screen : Easily configurable with buttons
    • Display Features : Shows instant and cumulative measurements; screen rotates 90 degrees for easy viewing
    • Multiple Pipe Diameters Available : (DN15 / DN25 / DN40 / DN50) for easy installation
    • Accuracy : ±2.0% F.S., pipeline withstand pressure of 16 bar
    • Multiple Outputs: Analog output / Relay / RS-485
  • Features
    • VCHEK LoZ low impedance measurement function to test for either AC or DC voltage, or show continuity if voltage is not detected.
    • Large backlit display
    • CAT IV 600 V safety rated
  • Features
    • Ideal Digital Multimeter for “go/no-go” testing
    • Features AutoVolt automatic AC/DC voltage selection
    • Includes low input impedance to help prevent false readings due to ghost voltage
    • Presents a large white LED backlight for working in poorly lit areas
    • Measures resistance and continuity
    • Provides Min/Max/Average with elapsed time to record signal fluctuations
  • Features 
    • Compact True-RMS digital multimeter for field service
    • Includes: meter, holster, 4 mm silicone test lead set
    • Easy one-handed operation of the meter
    • Min/Max/Average to record signal fluctuations
  • Features
    • Digital multimeter designed specifically for HVAC professionals
    • Includes built-in thermometer to measure temperature from -40°C to 400°C (-40°F to 752°F)
    • Provides microamps to test flame sensors
    • Features low input impedance to helps prevent false readings due to ghost voltage
    • Presents a large white LED backlight for working in poorly lit areas
  • Features
    • Compact, true-rms digital multimeter for electricians
    • Includes multimeter, 4mm silicone test leads, holster and manual
    • Integrated non-contact voltage detection keeps you safe
    • Prevent false readings from ghost voltage with selectable low-impedance mode
  • Features
    • Rugged, compact advanced insulation resistance tester for electrical contractors and industrial and commercial electricians
    • Automatically calculates Polarization Index and Dielectric Absorption Ratio
    • Makes repetitive tests simple and easy with a Compare (Pass/Fail) function
    • Offers multiple insulation test voltages: 50 V, 100 V, 250 V, 500 V, and 1000 V
  • Features
    • Auto discharge of capacitive voltage
    • AC/DC voltage
    • DC millivolts
    • AC/DC milliamps
    • Continuity
    • Auto power off to save battery power
    • True RMS
    • Large display with backlight
    • Live circuit detection prevents insulation test if voltage <30 V is detected for added user protection
    • CAT III 1000V, CAT IV 600V measurement category
  • Features
    • PI/DAR timed ratio tests
    • Live circuit detection prevents insulation test if voltage >30 V is detected for added user protection
    • VFD low-pass filter for accurate motor drive measurements
    • Auto-discharge of capacities voltage for added user protection
    • Insulation test of 0.01 MΩ to 2 GΩ
    • Insulation test voltages of 50, 100, 250, 500 V for many applications
    • AC/DC voltage, DC millivolts, AC/DC milliamps, resistance (Ω), continuity
    • Capacitance, diode test, temperature, Min/Max, frequency (Hz)
    • Auto power off to save battery power
    • CAT III 1000 V, CAT IV 600 V measurement category
    • Large display with backlight
    • Safety first. Keep yourself out of harm's way by monitoring your test measurements remotely
    • Prove your job is done right by quickly seeing and sharing measurement results wirelessly with your smartphone
    • Quickly find problems by saving and comparing measurements over time on a wireless device
  • Features
    • 3- and 4-pole Fall-of-Potential, earth resistance loop testing
    • 4-pole Soil Resistivity testing
    • Selective earth ground rod testing using 1 clamp
    • Stakeless earth ground rod testing using 2 clamps
    • IP56 rated for outdoor use
    • Rugged carrying case
    • USB data storage and transfer
  • Features
    • Includes "Insulation Pre-test" that detects when appliances are connected to the system and stops the test
    • Runs seven installation tests automatically in one sequence with a single connection through Auto Test
    • Allows you to share test results in real time over your smartphone via Fluke Connect Measurements
    • 6 mA RDC-DD testing for EV charging stations
  • Features
    • True-RMS digital multimeter with the features professional technicians prefer
    • Increases productivity with manual and automatic ranging, Display Hold, Auto Hold, and Min/Max-average recording
    • Measures AC and DC voltage to 1000 V
    • Delivers accurate True-RMS AC current and voltage plus frequency, capacitance, resistance, continuity and diode measurements
    • Safety rated CAT III 1000 V, CAT IV 600 V
  • Features
    • Automatically Measure Power And Power Quality Parameters
    • Intuitive User Interface
    • High-Speed Voltage Transient Capture
    • Analysis And Reporting
    • Energy Loss Calculator
  • Features
    • 1000V AC/DC; 10A AC/DC (with test leads and current jacks); resistance to 50 MΩ; capacitance to 10,000 μF, frequency to 100 kHz; temperature from -40 ℃ to 400 ℃
    • Robust, fast and accurate with manual and automatic ranging, Display Hold, Auto Hold, and Min/Max-Average recording
    • Backlit digital display, analog bar graph, and built-in temperature measurements with included thermocouple.
  • Features
    • IP 67 waterproof & dustproof protection, completely sealed for use in harsh environments
    • Designed to withstand 3 meter drop (with holster)
    • Unique function for accurate
  • Features
    • Rugged, reliable basic True-RMS clamp meter for measuring current up to 400 A
    • Measures AC current to 400 A
    • Measures AC voltage and DC voltage to 600 V
    • Provides True RMS AC voltage and current for accurate measurements on non-linear signals
    • Measures resistance to 4 kΩ with continuity detection
  • Features
    • Rugged, reliable basic True-RMS clamp meter for measuring current up to 400 A
    • Measures AC current to 400 A
    • Measures AC voltage and DC voltage to 600 V
    • Provides True RMS AC voltage and current for accurate measurements on non-linear signals
    • Measures resistance to 4 kΩ with continuity detection
  • Features
    •  True-rms AC/DC current, voltage, temperature, frequency
    • Clamp meter, test leads, K-type thermocouple and soft case
    • Versatile tool performs most front-line measurement tasks
  • Features
    • Electric pump for one handed pressure calibration
    • Best in class pressure measurement uncertainty of 0.025 %
    • Measure and source mA with best in class 0.015 % accuracy
    • Precision pressure adjust vernier
    • Variable release rate bleed valve for easy pressure adjustment
    • Ideal performance for high accuracy transmitter calibration
    • 30 PSI and 100 PSI pressure ranges
    • Programmable pump limit: - Eliminates over-pressurization - Allows the user to program target pressures for pumping
    • Extended measurement range with any of twenty-nine (29) 700Pxx Pressure Modules
    • Source mA with simultaneous pressure measurement to
    • test valves and I/Ps
    • Simulate mA signals to troubleshoot 4-20 mA loops
    • Test pressure switches with built in switch test function
    • Power transmitters during test using 24 V loop supply
    • Proven cleanout ports reduce pump failures
  • Features
    • Calibration of both temperature and pressure transmitters
    • Measure/source/simulate mA loop parameters
    • Measure and source mA, Volts DC, frequency, and resistance
    • Built-in 24 V loop power supply
    • Store and recall frequently used calibration set ups
  • Features
    • Large display
    • Backlight for work in dim areas
    • Min / Max to record signal fluctuations
    • Ergonomic overmolded housing with integrated probe holders
    • Free your hands with the optional TPAK magnetic hanger
    • Auto and Manual ranging
    • Meets Measurement Category 1000 V CAT III and Category IV 600 V safety standards
  • Features
    • Identify complex signal problems fast
    • Supports accurate measurements on VFDs using a low-pass filter
    • Captures intermittents as fast as 250 µS with Peak Capture
  • Features
    • Test the safety and functionality of AC electrical vehicle charging stations with the all-in-one solution
    • Pass/fail test results
    • Auto control pilot (CP) with waveform analysis
    • Compatible with TruTest™ Data Management Software
  • Features
    •  One pair (red, black) comfort grip probes with silicone insulated, right-angle test leads
    • Recommended for µV measurements
    • CAT II 1000 V, 10 A rating
    • CAT III 1000 V, CAT IV 600V only with protective cap
  • Features
    • Quickly configure, start and stop tests on the 1555 remotely, a safe distance away from any operating, energized equipment, using Fluke Connect® and a smart phone
    • Real time trending gives you easy-to-see visual cues, rather than hard to read, rapidly changing values
    • Report creation using Fluke Connect desktop saves time and makes test results easier to understand
    • Fluke Connect saves test results to the cloud for analysis and preventive maintenance
  • Features
    •  Measurement accuracy 1%
    • Converter IP rating IP 67, transducer IP rating IP 68
    • Wide measurement range, pipe size from DN15 mm to DN6000 mm
    • Connect the temperature transducer can finish the heat / energy measurement
  • Main Function
    • Embedded run/stop switch, motor on/off, load run, auto-stop, manual stop, operation delay, load delay, embedded timer
    • Pressure / temperature high level
    • Temperature low level (standby for starting)
    • Interlock input signal (emergency switch, OCR reverse phase)
    • Usable thermometer and manometer
    • RS485 communication (MODBUS)
     
  • Main Function
    • Embedded run/stop switch, motor on/off, load run, auto-stop, manual stop, operation delay, load delay, embedded timer
    • Pressure / temperature high level
    • Temperature low level (standby for starting)
    • Interlock input signal (emergency switch, OCR reverse phase)
    • Usable thermometer and manometer
    • RS485 communication (MODBUS)
     
  • Main Function
    • Total control and detection (protection) for freezers
    • Function of start, restart, pump down, alarm delay timer
    • Discharge gas detection (high & low temperature)
    • Individual alarm message (OC, HP, LP, OP, INT)
    • RS485 communication (MODBUS)
     
  • Main Function
    • PID degree of superheat control through defense and safety compensation
    • Degree of superheat control for various refrigerant
    • PMW (opening ratios control)
    • Remote operation
    • Transmission output
    • RS485 communication (MODBUS)
     
  • Main Function
    • 3 stage fan speed controllable
    • 4 kind (stop / high / middle / low) airflow choosable
    • Unification of temperature control function
    • Data backup
    • Self diagnostic
    • RS485 communication (MODBUS)
     
  • Main Function
    • Defrosting (auto / manual)
    • Fan control
    • Efficient delay
    • Room temperature sensor: 1EA
    • Defrost sensor: 1EA
    • High (low) temperature alarm output
    • Room temperature transmission output (4~20 mA)
    • RS485 communication (MODBUS)
     
  • Main Function
    • Efficient defrosting in geothermy heat pump system
    • Defrosting execution by measuring of ambient humidity and temperature
     
  • Main Function
    • Output controllable based on measured pressure value (increase and decrease)
    • Alternative operation available between freezing exclusive model and booster
    • Pump unit control model
    • RS485 MODBUS
     
  • Main Function
    • Uniform step control
    • Operation with intelligent shift high / low alarm output
    • Sensor correction / Sensor error detection
    • Transmission output
    • RS485 communication (MODBUS)
     
  • Main Function
    • Defrosting (auto / manual)
    • Defrosting stop delay
    • Evaporation fan control
    • Air inlet/outlet sensor: 2EA
    • Defrost recovery sensor: 1EA
    • Virtual temperature sensor computing
    • Door open alarm
    • Emergency call
    • Night operation
    • High (low) temperature alarm output
    • RS485 communication (MODBUS)
     
  • Main Function
    • Defrosting (auto / manual)
    • Defrosting stop delay
    • 2 air inlet/outlet sensors
    • One sensor for defrost recovery
    • High / Low alarm output
    • Indicator (FixView) connection
    • RS485 communication (MODBUS)
     
  • Main Function
    • Heating / cooling output
    • Independent timer output
    • High / Low alarm output
    • Defrost output
    • Precise temperature control
    • Sensor correction
    • Sensor error detection
    • Data back up
    • Minimum on/off maintaining time setup
    • RS485 communication (MODBUS)
    • Transmission output
    • Auto-output operation cycle settable in case of sensor error
     
  • Features
    • Humidification (heating)
    • Dehumidification (cooling) output
    • High/Low alarm output
    • Min. on/off maintaining time setup
    • Selection on/off output when sensor error occurs
    • Sensor correction
    • Sensor error detection
    • Relay output manual control
    • Transmission output
    • RS485 communication (MODBUS)
  • Main Function
    • Heating / cooling output
    • Independent timer output
    • High / Low alarm output
    • Defrost output
    • Precise temperature control
    • Sensor correction
    • Sensor error detection
    • Data back up
    • Minimum on/off maintaining time setup
    • RS485 communication (MODBUS)
    • Transmission output
    • Auto-output operation cycle settable in case of sensor error
  • Main Function
    • Humidification/dehumidification output
    • High/Low alarm output
    • Min. on/off maintaining time setup
    • Selection on/off output when sensor error occurs
    • Sensor correction
    • Sensor error detection
    • Selection of displaying decimal point
     
  • Main Function
    • Heating / cooling output
    • High / Low alarm output
    • Precise temperature control
    • Sensor correction
    • Sensor error detection
    • Data back up
    • Minimum on/off maintaining time setup
    • RS485 communication (MODBUS)
    • Transmission output
     
  • Main Function
    • Heating / cooling output
    • Precise temperature control
    • Sensor correction
    • Sensor error detection
    • Data back up
    • Minimum on/off maintaining time setup
    • Auto-output operation cycle settable in case of sensor error
     
  • Main Function
    • Heating/cooling output
    • High / Low alarm output
    • Precise temperature control.
    • Sensor correction, sensor error detection
    • Sensor error detection
    • Data backup
    • Min. on/off maintaining time setup
    • Transmission output
    • RS485 communication (MODBUS)
  • Main Function
    • Heating / cooling output
    • Independent timer output
    • High / Low alarm output
    • Precise temperature control
    • Sensor correction
    • Sensor error detection
    • Data back up
    • Minimum on/off maintaining time setup
    • RS485 communication (MODBUS)
    • Transmission output
     
  • Features
    • Uses a multi-fin, centrifugal level vertical heat exchange circulation system; ventilation rate can be adjusted to the desired rate.
    • Internal rotating pan can be convenient removed and installed, the motor rotating speed of hang shelf is 8-10 rpm.
    • A digital watt/hour meter and timer can be used to present the air refresh rate.
  • Features
    • Panel Dimension: 1.5" - 3.4"; 14.1" - 42"
    • CLCD-9700 Color touch panel controller was made in Japan
    • Forced air in and out to control the loading of specimen
    • Wider viewing glass design and have a connecting to safety protection device
    • Easily changed design as your product changes
  • Features
    • Measured parameters: carbon dioxide, temperature, and humidity (optional)
    • Superior long-term stability with the latest-generation Vaisala CARBOCAPâ sensor
    • Accurate temperature and humidity measurements due to the low-power microglow infrared source
    • Quick and easy installation and maintenance
    • Calibrated, user-exchangeable measurement modules
    • 23-point traceable CO2 calibration (certification included)
    • Both analog and field bus communication (Modbusâ RTU)
  • Features 
    • Adopt computerized electronic digital control, precise & reliable.
    • The packing of box insulation is molded by silicone, high-temperature enduring & never aged attached with observation view window, easy to be used
    • Heating is by compulsory circulating ventilation, temperature raising is fast and spread even
    • Provide the P.I.D control system, double sided overheating protection, safe & reliable.
    • Easy to set temperature, easier to operate
    • Attached with two sets of moveable disks to be adjusted high and low at your dispel
  • Features
    • Made entirely of P.P & PVC, resistant to acids, bases and heat. It can be used with salt spray acetic acid, or any other testing material.
    • Patented nozzle and conical dispersion unit ensure even spraying rate
    • It can be controlled manually, or for up 9,991 hours of operation
    • At the end of the experiment, a defogger automatically cleans the inside of the testing chamber for specimen.
    • Three set temperature controlling systems of air-tank temperature, test area temperature, solution temperature. To make sure the correctness amd standard of the testing.
  • Features
    • T-Bar Design
    • 1-Second Measuring Interval
    • Max. - Min. Function
    • Auto Off-Function
    • Water-Tight
    • Protective cover and pocket clips included
  • Features
    • System capacity: It could sign in 150 programs x 1500 partitions, partitions can be optionally divided and program can link up to each other.
    • Loop configuration: 9999 x 999 looping time, can be divided into 5 independent sub-loops
    • Output: Intelligent PID + SSR/ SCR two-way synchronous output, built-in advanced slope control logic
    • Data: Touch panel dialogue box display, easy operation, built-in managemnet system of data content
    • Curves drawing: When temperature, humidity and times are set up, the data can be immediately transferred into curves, actual operating curves can be attained during operations
  • Features 
    • On desk design affords small volume with occupying space
    • All programmed instructions are microprocessor-controlled. with PID and automatic calculation to ensure precise and stable temperature and humidity control.
    • In the case of thermostat breakdown, a warning light switches on and temperature setting is changed to standard
    • Heat is evenly distributed throughout the testing chamber to ensure a uniform testing temperature
  • Features
    • The design mode of these sets is one body affords convenient application and less space occupation.
    • It can separately test high temperature and constant temperature and humidity.
    • All systems are individual and independent. The three sets type of the refrigstion system and three sets of the type heating and humidifying systems are adopted. The three set type systems afford stable control and high accuracy, prolonging the service life machine parts.
    • All programmed instructions are microprocessor-controlled, with PID and automatic calculation to ensure precise and stable temperature and humidity control.
  • Features
    • This equipment features independent systems with vibration control and cross-temperature and cross-humidity controls. It can be set to test and display results for high temperatures, low temperatures, cross temperatures and humidity and vibration, either individually or at the same time.
    • Moveable guide rails for easy testing separately or simultaneously.
    • Large LCD display in Chinese or English plus 100-program memory and standard RS-232C computer interface.
Go to Top