Loading...
  • Features
    • DMT345 measures humidity at temperatures up to 180 °C (356 °F)
    • DMT346 measures humidity at temperatures up to 350 °C (+662 °F)
    • Dew point accuracy ±2 °C (±3.6 °F)
    • Condensation-resistant
    • Unique auto-calibration feature
    • Analog outputs, RS-232/485, WLAN/LAN
    • Modbus protocol support (RTU/ TCP)
  • Features
    • Measures dew point from -70 ... +80 °C (-94 ... +176 °F) with an accuracy of ±2 °C (±3.6 °F)
    • Condensation-resistant
    • Unique auto-calibration feature maintains accuracy over long term
    • Compatible with Vaisala DRYCAP Handheld Dew Point Meter DM70
    • Traceable calibration to measurements and analog outputs (certificates included)
    • Graphical display and keypad for convenient operation
    • Optional alarm relays and mains power supply module
    • Up to three analog outputs, RS-232/485, LAN
    • Modbus protocol support (RTU/ TCP)
  • Features
    • Vaisala DRYCAP technology with a polymer sensor
    • Measures dew point down to -80 °C (-112 °F)
    • Withstands condensation
    • Traceable calibration (certificate included)
    • Applications: dry chambers, dry gases, semiconductor manufacturing, research and testing, and compressed air
  • Features
    • High accuracy ±1°C (±1.8°F) in the measurement range of refrigerant dryers
    • Low power requirements, 10 .... 28 VDC
    • Optional LED warning light
    • Optional loop powered display, Nokeval 301
  • Features
    • Dew point measurement range −70 … +80 °C (−94 … +176 °F) Td/f
    • Dew point measurement accuracy up to ±2 °C (±3.6 °F) Td/f
    • Operating pressure of probe head 0 … 4 MPa (0 … 40 bar)
    • Adjustable installation depth
    • Tolerates condensation, oils, dust, and most chemicals
    • Sensor purge provides superior chemical resistance
    • Modbus RTU over RS-485
    • Compatible with Indigo transmitters and Insight PC software
    • Traceable calibration certificate
  • Features
    • Dew point measurement range −70 … +80 °C (−94 … +176 °F) Td/f
    • Dew point measurement accuracy up to ±2 °C (±3.6 °F) Td/f
    • Sensor purge provides superior chemical resistance
    • Tolerates condensation, oils, dust, and most chemicals
    • Modbus RTU over RS-485
    • Compatible with Indigo transmitters and Insight PC software
    • Traceable calibration certificate
  • Features
    • Measures humidity at high temperatures up to +350 °C (+662 °F)
    • Dew point measurement range −25 … +100 °C (−13 … +212 °F) Td/f
    • Dew point measurement accuracy up to ±2 °C (±3.6 °F) Td/f
    • Sensor purge provides superior chemical resistance
    • Condensation-tolerant Modbus RTU over RS-485
    • Compatible with Indigo transmitters and Insight PC software
    • Traceable calibration certificate
     
  • Features
    • Measures humidity at temperatures up to +180 °C (+356 °F)
    • Dew point measurement range−40 … +100 °C (−40 … +212 °F) Td/f
    • Dew point measurement accuracy up to ±2 °C (±3.6 °F) Td/f
    • Sensor purge provides superior chemical resistance
    • Condensation-tolerant
    • Modbus RTU over RS-485
    • Compatible with Indigo transmitters and Insight PC software
    • Traceable calibration certificate
     
  • Characteristics
    • Stainless Steel Sensor
    • Nominal pressure from 0 ... 400 mbar up to 0 ... 600 bar
    • accuracy according to IEC 60770: 0.1 % FSO
    • Preferred areas of use for Process, Oil And Gas Industry
    • Communication interface for adjusting of offset, span and damping
  • Characteristics
    • Stainless Steel Sensor
    • Nominal pressure ranges from
    • Accuracy according to IEC 60770: standard: 0.35 % FSO option: 0.25 % FSO
  • Characteristics
    • Stainless Steel Sensor, Without Media Isolation, HVAC
    • Nominal pressure ranges from 0 ... 10 mbar up to 0 ... 1000 mbar
    • Accuracy according to IEC 60770: 0.35 % FSO
  • Characteristics
    • Stainless Steel Sensor Flush Version G 1/4
    • Nominal pressure ranges from 0 ... 60 bar to 0 ... 600 bar
    • Accuracy according to IEC 60770: 0.35 % FSO
  • Characteristics
    • Welded, Dry Stainless Steel Sensor
    • Nominal pressure range from 0 ... 6 bar up to 0 ... 600 bar
    • Accuracy according to IEC 60770: 0.5 % FSO
    • Preferred areas of use for Medical Technology
  • Characteristics
    • Thinfilm Sensor
    • Nominal pressure ranges from 0 ... 600 bar up to 0 ... 2200 bar
    • Accuracy according to IEC 60770: 0.1 % FSO
    • Preferred areas of use for Welded, Plant And Machine Engineering
       
  • Characteristics
    • Thinfilm Sensor
    • Nominal pressure range from 0 ... 600 bar up to 0 ... 2200 bar
    • Accuracy according to IEC 60770: 0.35 % FSO
    • Preferred areas of use for Plant & Mechanical Engineering
  • Characteristics
    • Stainless Steel Sensor
    • Universal Application
    • Nominal pressure from 0 ... 100 bar up to 0 ... 600 bar
    • Accuracy according to IEC 60770: standard: 0.35 % FSO option: 0.25 / 0.1 % FSO
  • Characteristics
    • Process Connections with Flush Welded Stainless Steel Diaphragm
    • Hygienical Application
    • Nominal pressure  range from 0...100 mbar Up To 40 bar nominal pressure
    • Accuracy according to IEC 60770: 0.1 % FSO
  • Characteristics
    • Pressure Ports and Process Connections with Flush Welded Stainless Steel Diaphragm
    • Nominal pressure ranges from 0 ... 400 mbar up to 0 ... 40 bar
    • Accuracy according to IEC 60770: 0.1 % FSO
  • Characteristics
    • Stainless Steel Sensor
    • Universal Application
    • Nominal pressure ranges from 0...100mBar Up To 60 bar
    • Accuracy according to IEC 60770: standard: 0.35 % FSO option: 0.25 / 0.1 % FSO
  • Characteristics
    • Stainless Steel Sensor
    • Universal Application
    • Nominal pressure from 0 ... 100 mbar up to 0 ... 600 bar
    • Accuracy according to IEC 60770: standard: 0.25 % FSO option: 0.1 % FSO
  • Characteristics
    • Stainless Steel Sensor, With Fast Response
    • Nominal pressure ranges from 0...100 mbar up to 0...600 bar
    • Accuracy according to IEC 60770: 0.1 % FSO
  • Characteristics
    • Nominal pressure range from 0 ... 2 000 bar up to 0 ... 6 000 bar
    • Stainless Steel Sensor (Strain Gauge), Oil & Gas
    • Accuracy according to IEC 60770: standard: 0.5 % FSO option: 0.25 % FSO
  • Characteristics
    • Ceramic Sensor
    • Accuracy according to IEC 60770: Standard: 0.25 % FSO Option: 0.1 % FSO
  • Characteristics
    • Ceramic Sensor, Marine, Shipbuilding, Offshore,
    • Nominal pressure  range from 0...400 mbar Up To 600 Bar
    • Accuracy according to IEC 60770: 0.5 % FSO
     
  • Characteristics
    • Nominal pressure  from 0...40 mbar Up To 20 Bar
    • Ceramic Sensor, Flush, Hygienical Application
    • Accuracy according to IEC 60770: Standard: 0.35 % FSO Option: 0.25 % FSO
  • Characteristics
    • Pressure Ports with Flush Welded Stainless Steel Diaphragm
    • Accuracy according to IEC 60770: 0.5 % FSO
  • Characteristics
    • Ceramic Sensor
    • Accuracy according to IEC 60770: 0.5 % FSO
  • Characteristics:
    •  2 piezoresistive stainless steel sensors
    • Differential pressure from 0 ... 1 bar up to 0 ... 70 bar
    • Display and pressure port rotatable
  • Characteristics:
    • Silicon Sensor, Plant And Mechanical Engineering
    • Differential l pressure ranges from 0 ... 6 mbar up to 0 ... 1000 mbar
    • accuracy according to IEC 60770: 0.35 % / 1% / 2%
     
  • Characteristics:
    • Stainless Steel Sensor, Plant And Mechanical Engineerin
    • Differential pressure ranges from 0 ... 20 mbar up to 0 ... 16 bar
    • Accuracy according to IEC 60770: 0.5 % FSO
  • Feature
    • 4-in-1 Monitor PM2.5, CO2, temperature & humidity via RS-485 at the same time.
    • High Brightness LED Easily recognize measuring types and values.
    • 6-segment CO2 Emoticon As the local situation and refer to CO2 indication standards to transfer the suitable emoticon
    • 6-segment PMV Indication Refer to PMV indication to display the real-time body sensing.
    • Bargain Set eYc Multifunction PM2.5 Indoor Air Quality Monitor ( type : eYc TGP03 )
     
  • Feature
    • Dual Beam NDIR technology is used to measure CO2 concentration
    • Audible Alarm
    • Data Logging with SD Card
    • RS485 Communication Interface
    • Rechargeable Battery
    Easy Handle CO2 Quality To Upgrade, Work Efficiency in Jaunty breath Real-Time, React Quickly, High Brightness LED
  • Features
    • Designed for industrial spot checking and field calibration
    • Three models: accurate measurement ranges from −60 to +60 °C (−76 ... +140 °F)
    • Vaisala DRYCAPâ sensor with unique auto calibration function
    • Sensor withstands condensation
    • Data can be logged and transferred to a PC via MI70 Link software
    • Traceable calibration (certificate included)
    • Fast response, enhanced by sensor purge option
    • Variety of sampling cell options for connection to pressurized processes
       
  • Features
    • Single and multi-channel models with up to four input channels
    • Easily set scaling and measurement units for recording
    • Time-based digital recording in a range of sample intervals
    • Multiple connectivity options - USB, Ethernet, WiFi
    • Optional vNet cradle for Ethernet or Power over Ethernet connectivity
    • Traceable to SI units through national metrology institutes.
    • 10-year battery and large onboard memory
    • Two year limited warranty
  • Features
    • Industry-leading temperature and relative humidity measurement precision
    • High accuracy, adjustable timebased digital recording
    • Printed reports for any time period
    • Ability to perform validation and continuous monitoring with the same model
    • Traceable to SI units through national metrology institutes
    • Superior alternative to chart recorders and hard-wired systems
    • Integrated high-accuracy RH sensor
    • 10-year battery
  • Features
    • Accepts type J, K, T, E, R and S thermocouples
    • No programming or complicated equations required
    • Highly accurate replacement for data acquisition systems
    • Traceable to SI units through national metrology institutes
Go to Top