Loading...
  • Characteristics
    • Stainless Steel Sensor
    • Accuracy according to IEC 60770:
    • Standard: 0.25 % FSO
    • Option: 0.1 % FSO
  • Characteristics
    • Stainless Steel Sensor
    • Accuracy according to IEC 60770:
    • Standard: ≤ ± 0.35 % FSO
    • Option: ≤ ± 0.25 % FSO
  • Characteristics
    • Stainless Steel Sensor
    • Accuracy according to IEC 60770: standard: ≤ ± 0.35 % FSO option: ≤ ± 0.25 % FSO
  • Characteristics
    • Ceramic Sensor
    • Accuracy according to IEC 60770: 0.5 % FSO
  • Characteristics
    • Ceramic Sensor
    • Accuracy according to IEC 60770: 0.5 % FSO
  • Features
    • LED digital display and operation panel
    • Automatic swing function. Low/ High air speed
    • Purification Function: Active Carbon
    • Both bucket and continuous hose drain
    • Low temperature auto-defrost
    • 1-24 hours timer on timer off
    • Automatic water full alarm and stop
    • Power memory and restart function function
    • Universal castors, eave to move around
  • Features
    • LED digital display and operation panel
    • Washable coarse air filter, easy to maintain
    • PGMCC (R410a) brand compressor
    • Both bucket and continuous hose drain
    • Low temperature auto-defrost
    • 1-24 hours timer on and timer off
    • Automatic water full alarm and stop
    • Universal castors, eave to move around
  • Features
    • LED digital display and operation panel
    • Washable coarse air filter, easy to maintain
    • PGMCC (R410a) brand compressor
    • Both bucket and continuous hose drain
    • Low temperature auto-defrost
    • 1-24 hours timer on and timer off
    • Automatic water full alarm and stop
    • Universal castors, eave to move around
  • Features
    • Stand-alone use or use within automated system of personal dosimetry control.
    • Storage of dose accumulation history in the nonvolatile memory with real time reference.
    • Transfer of dose accumulation history through the infrared port to the computer.
    • Blocking the mode of power supply switch off until the data reading procedure finished.
    • DER and DE threshold levels programming of gamma and X-ray radiation with the help of the computer or manually with control keys.
    • Blocking certain indication modes in response to the computer command.
    • Light and audio alarms when programmed threshold levels exceeded on DER and DE of gamma and X-ray radiation.
    • Display automatic switch off if current gamma background is lower than the preset threshold level with instant switching on at: – pressing any control key; – gamma background increase above the preset threshold level; – alarm clock ringing.
    • Periodic self-testing of batteries and detector.
    • Energy-compensated Geiger-Muller counter.
  • Features
    • IP54 ingress protection rating.
    • Stand-alone use or use within automated system of personal dosimetry control.
    • Storage of dose accumulation history in the nonvolatile memory with real time reference.
    • Transfer of dose accumulation history through the infrared port to the computer.
    • Blocking the mode of power supply switch off until the data reading procedure finished.
    • Gamma radiation DER and DE threshold levels programming with the help of the computer or manually with control keys.
    • Blocking certain indication modes in response to the computer command.
    • Light and audio alarms when programmed threshold levels exceeded on DER and DE of gamma radiation.
    • Display automatic switch off if current gamma background is lower than the preset threshold level with instant switching on at: – pressing any control key; – gamma background increase above the preset threshold level; – alarm clock ringing.
    • Periodic self-testing of batteries and detector.
    • Energy-compensated Geiger-Muller counter.
  • Features
    • Bump testing, calibration, configuration and data recording on a single station
    • Fast–up to 3 units bumped or calibrated simultaneously
    • Portable, using battery power for up to 3000 bump tests
    • Upgrades Docking Firmware
    • Robust–All-in-one hard case and data analysis
    • With 32G SD card, more than 10,0000 sets data can be recorded
    • Saves the bump ,calibration,configuration data in station and support U-disk connection for data and calibration report export
    • Includes Safegas PC software for easy configuration
  • Features
    • Bump testing, calibration, configuration and data recording on a single station
    • Fast–up to 4 units bumped or calibrated simultaneously
    • Portable, using battery power for up to 3000 bump tests
    • Upgrades Docking Firmware
    • Robust–All-in-one hard case and data analysis
    • With 32G SD card, more than 10,0000 sets data can be recorded
    • Saves the bump ,calibration,configuration data in station and support U-disk connection for data and calibration report export
    • Includes Safegas PC software for easy configuration
  • Features
    • Bump testing, calibration, configuration and data recording on a single station
    • Fast–up to 1 units bumped or calibrated simultaneously
    • Portable, using battery power for up to 3000 bump tests
    • Upgrades Docking Firmware
    • Robust–All-in-one hard case
    • With 32G SD card, more than 10,0000 sets data can be recorded
    • Saves the bump, calibration,configuration data in station and support U-disk connection for data and calibration report export
    • Includes Safegas PC software for easy configuration and data analysis
  • Features
    • Industry-leading precision and accuracy
    • Printed reports for any time period
    • Internal battery with up to 10 years' lifetime
    • Validation and continuous monitoring with the same model
    • Superior alternative to chart recorders and hard-wired systems
    • Timebase calibrated over the operating temperature range
    • Adjustable time-based recording
    • Snap-in logger cradle for easy network connectivity
    • Two probe options give high accuracy – from −90 °C to +70 °C (−130 °F to +158 °F)
    • Traceable to SI units through national metrology institutes
    • 2-year limited warranty
  • Features
    • Industry-leading precision and accuracy
    • Real-time monitoring & alarming with viewLinc software
    • Reliable validation/mapping with vLog software
    • Easy connectivity to your existing network – wired or wireless
    • Validation and continuous monitoring with the same datalogger
    • Superior alternative to chart recorders and hard-wired systems
    • Traceable to SI units through national metrology institutes
  • Features
    • Accepts type J, K, T, E, R and S thermocouples
    • No programming or complicated equations required
    • Highly accurate replacement for data acquisition systems
    • Traceable to SI units through national metrology institutes
  • Features
    • Industry-leading temperature and relative humidity measurement precision
    • High accuracy, adjustable timebased digital recording
    • Printed reports for any time period
    • Ability to perform validation and continuous monitoring with the same model
    • Traceable to SI units through national metrology institutes
    • Superior alternative to chart recorders and hard-wired systems
    • Integrated high-accuracy RH sensor
    • 10-year battery
  • Features
    • Single and multi-channel models with up to four input channels
    • Easily set scaling and measurement units for recording
    • Time-based digital recording in a range of sample intervals
    • Multiple connectivity options - USB, Ethernet, WiFi
    • Optional vNet cradle for Ethernet or Power over Ethernet connectivity
    • Traceable to SI units through national metrology institutes.
    • 10-year battery and large onboard memory
    • Two year limited warranty
  • Features
    • Designed for industrial spot checking and field calibration
    • Three models: accurate measurement ranges from −60 to +60 °C (−76 ... +140 °F)
    • Vaisala DRYCAPâ sensor with unique auto calibration function
    • Sensor withstands condensation
    • Data can be logged and transferred to a PC via MI70 Link software
    • Traceable calibration (certificate included)
    • Fast response, enhanced by sensor purge option
    • Variety of sampling cell options for connection to pressurized processes
       
  • Feature
    • Dual Beam NDIR technology is used to measure CO2 concentration
    • Audible Alarm
    • Data Logging with SD Card
    • RS485 Communication Interface
    • Rechargeable Battery
    Easy Handle CO2 Quality To Upgrade, Work Efficiency in Jaunty breath Real-Time, React Quickly, High Brightness LED
  • Feature
    • 4-in-1 Monitor PM2.5, CO2, temperature & humidity via RS-485 at the same time.
    • High Brightness LED Easily recognize measuring types and values.
    • 6-segment CO2 Emoticon As the local situation and refer to CO2 indication standards to transfer the suitable emoticon
    • 6-segment PMV Indication Refer to PMV indication to display the real-time body sensing.
    • Bargain Set eYc Multifunction PM2.5 Indoor Air Quality Monitor ( type : eYc TGP03 )
     
  • Characteristics:
    • Stainless Steel Sensor, Plant And Mechanical Engineerin
    • Differential pressure ranges from 0 ... 20 mbar up to 0 ... 16 bar
    • Accuracy according to IEC 60770: 0.5 % FSO
  • Characteristics:
    • Silicon Sensor, Plant And Mechanical Engineering
    • Differential l pressure ranges from 0 ... 6 mbar up to 0 ... 1000 mbar
    • accuracy according to IEC 60770: 0.35 % / 1% / 2%
     
  • Characteristics:
    •  2 piezoresistive stainless steel sensors
    • Differential pressure from 0 ... 1 bar up to 0 ... 70 bar
    • Display and pressure port rotatable
  • Characteristics
    • Ceramic Sensor
    • Accuracy according to IEC 60770: 0.5 % FSO
  • Characteristics
    • Pressure Ports with Flush Welded Stainless Steel Diaphragm
    • Accuracy according to IEC 60770: 0.5 % FSO
  • Characteristics
    • Nominal pressure  from 0...40 mbar Up To 20 Bar
    • Ceramic Sensor, Flush, Hygienical Application
    • Accuracy according to IEC 60770: Standard: 0.35 % FSO Option: 0.25 % FSO
  • Characteristics
    • Ceramic Sensor, Marine, Shipbuilding, Offshore,
    • Nominal pressure  range from 0...400 mbar Up To 600 Bar
    • Accuracy according to IEC 60770: 0.5 % FSO
     
  • Characteristics
    • Ceramic Sensor
    • Accuracy according to IEC 60770: Standard: 0.25 % FSO Option: 0.1 % FSO
  • Characteristics
    • Nominal pressure range from 0 ... 2 000 bar up to 0 ... 6 000 bar
    • Stainless Steel Sensor (Strain Gauge), Oil & Gas
    • Accuracy according to IEC 60770: standard: 0.5 % FSO option: 0.25 % FSO
  • Characteristics
    • Stainless Steel Sensor, With Fast Response
    • Nominal pressure ranges from 0...100 mbar up to 0...600 bar
    • Accuracy according to IEC 60770: 0.1 % FSO
  • Characteristics
    • Stainless Steel Sensor
    • Universal Application
    • Nominal pressure from 0 ... 100 mbar up to 0 ... 600 bar
    • Accuracy according to IEC 60770: standard: 0.25 % FSO option: 0.1 % FSO
  • Characteristics
    • Stainless Steel Sensor
    • Universal Application
    • Nominal pressure ranges from 0...100mBar Up To 60 bar
    • Accuracy according to IEC 60770: standard: 0.35 % FSO option: 0.25 / 0.1 % FSO
  • Characteristics
    • Pressure Ports and Process Connections with Flush Welded Stainless Steel Diaphragm
    • Nominal pressure ranges from 0 ... 400 mbar up to 0 ... 40 bar
    • Accuracy according to IEC 60770: 0.1 % FSO
  • Characteristics
    • Process Connections with Flush Welded Stainless Steel Diaphragm
    • Hygienical Application
    • Nominal pressure  range from 0...100 mbar Up To 40 bar nominal pressure
    • Accuracy according to IEC 60770: 0.1 % FSO
  • Characteristics
    • Stainless Steel Sensor
    • Universal Application
    • Nominal pressure from 0 ... 100 bar up to 0 ... 600 bar
    • Accuracy according to IEC 60770: standard: 0.35 % FSO option: 0.25 / 0.1 % FSO
Go to Top