Loading...
  • Characteristics
    • Process Connections with Flush Welded Stainless Steel Diaphragm
    • Hygienical Application
    • Nominal pressure  range from 0...100 mbar Up To 40 bar nominal pressure
    • Accuracy according to IEC 60770: 0.1 % FSO
  • Characteristics
    • Stainless Steel Sensor
    • Universal Application
    • Nominal pressure from 0 ... 100 bar up to 0 ... 600 bar
    • Accuracy according to IEC 60770: standard: 0.35 % FSO option: 0.25 / 0.1 % FSO
  • Characteristics
    • Thinfilm Sensor
    • Nominal pressure range from 0 ... 600 bar up to 0 ... 2200 bar
    • Accuracy according to IEC 60770: 0.35 % FSO
    • Preferred areas of use for Plant & Mechanical Engineering
  • Characteristics
    • Thinfilm Sensor
    • Nominal pressure ranges from 0 ... 600 bar up to 0 ... 2200 bar
    • Accuracy according to IEC 60770: 0.1 % FSO
    • Preferred areas of use for Welded, Plant And Machine Engineering
       
  • Characteristics
    • Welded, Dry Stainless Steel Sensor
    • Nominal pressure range from 0 ... 6 bar up to 0 ... 600 bar
    • Accuracy according to IEC 60770: 0.5 % FSO
    • Preferred areas of use for Medical Technology
  • Characteristics
    • Stainless Steel Sensor Flush Version G 1/4
    • Nominal pressure ranges from 0 ... 60 bar to 0 ... 600 bar
    • Accuracy according to IEC 60770: 0.35 % FSO
  • Characteristics
    • Stainless Steel Sensor, Without Media Isolation, HVAC
    • Nominal pressure ranges from 0 ... 10 mbar up to 0 ... 1000 mbar
    • Accuracy according to IEC 60770: 0.35 % FSO
  • Characteristics
    • Stainless Steel Sensor
    • Nominal pressure ranges from
    • Accuracy according to IEC 60770: standard: 0.35 % FSO option: 0.25 % FSO
  • Characteristics
    • Stainless Steel Sensor
    • Nominal pressure from 0 ... 400 mbar up to 0 ... 600 bar
    • accuracy according to IEC 60770: 0.1 % FSO
    • Preferred areas of use for Process, Oil And Gas Industry
    • Communication interface for adjusting of offset, span and damping
  • Features
    • Measures humidity at temperatures up to +180 °C (+356 °F)
    • Dew point measurement range−40 … +100 °C (−40 … +212 °F) Td/f
    • Dew point measurement accuracy up to ±2 °C (±3.6 °F) Td/f
    • Sensor purge provides superior chemical resistance
    • Condensation-tolerant
    • Modbus RTU over RS-485
    • Compatible with Indigo transmitters and Insight PC software
    • Traceable calibration certificate
     
  • Features
    • Measures humidity at high temperatures up to +350 °C (+662 °F)
    • Dew point measurement range −25 … +100 °C (−13 … +212 °F) Td/f
    • Dew point measurement accuracy up to ±2 °C (±3.6 °F) Td/f
    • Sensor purge provides superior chemical resistance
    • Condensation-tolerant Modbus RTU over RS-485
    • Compatible with Indigo transmitters and Insight PC software
    • Traceable calibration certificate
     
  • Features
    • Dew point measurement range −70 … +80 °C (−94 … +176 °F) Td/f
    • Dew point measurement accuracy up to ±2 °C (±3.6 °F) Td/f
    • Sensor purge provides superior chemical resistance
    • Tolerates condensation, oils, dust, and most chemicals
    • Modbus RTU over RS-485
    • Compatible with Indigo transmitters and Insight PC software
    • Traceable calibration certificate
  • Features
    • Dew point measurement range −70 … +80 °C (−94 … +176 °F) Td/f
    • Dew point measurement accuracy up to ±2 °C (±3.6 °F) Td/f
    • Operating pressure of probe head 0 … 4 MPa (0 … 40 bar)
    • Adjustable installation depth
    • Tolerates condensation, oils, dust, and most chemicals
    • Sensor purge provides superior chemical resistance
    • Modbus RTU over RS-485
    • Compatible with Indigo transmitters and Insight PC software
    • Traceable calibration certificate
  • Features
    • High accuracy ±1°C (±1.8°F) in the measurement range of refrigerant dryers
    • Low power requirements, 10 .... 28 VDC
    • Optional LED warning light
    • Optional loop powered display, Nokeval 301
  • Features
    • Vaisala DRYCAP technology with a polymer sensor
    • Measures dew point down to -80 °C (-112 °F)
    • Withstands condensation
    • Traceable calibration (certificate included)
    • Applications: dry chambers, dry gases, semiconductor manufacturing, research and testing, and compressed air
  • Features
    • Measures dew point from -70 ... +80 °C (-94 ... +176 °F) with an accuracy of ±2 °C (±3.6 °F)
    • Condensation-resistant
    • Unique auto-calibration feature maintains accuracy over long term
    • Compatible with Vaisala DRYCAP Handheld Dew Point Meter DM70
    • Traceable calibration to measurements and analog outputs (certificates included)
    • Graphical display and keypad for convenient operation
    • Optional alarm relays and mains power supply module
    • Up to three analog outputs, RS-232/485, LAN
    • Modbus protocol support (RTU/ TCP)
  • Features
    • DMT345 measures humidity at temperatures up to 180 °C (356 °F)
    • DMT346 measures humidity at temperatures up to 350 °C (+662 °F)
    • Dew point accuracy ±2 °C (±3.6 °F)
    • Condensation-resistant
    • Unique auto-calibration feature
    • Analog outputs, RS-232/485, WLAN/LAN
    • Modbus protocol support (RTU/ TCP)
  • Features
    • Geiger-Muller counters without return run of counting response.
    • Analog indicator of radiation intensity.
    • Up to 4096 measurement results recording in the nonvolatile memory with further transfer to the computer through infrared port.
    • Review of the recorded measurement results on the display.
    • “Precisely” channel with the average result indicated on the display for the fixed measurement time from 1 to 99 minutes.
    • Detection of soft beta radiation.
    • Programmable threshold levels of gamma and X-ray radiation dose equivalent rate and beta-particles flux density.
    • Audio signaling of detected gamma-quanta, beta-particles, and exceeded programmed threshold levels of dose equivalent rate of gamma and X-ray radiation or beta-particles flux density.
    • Display backlight.
    • Multilevel indication for battery discharge.
  • Characteristics
    • Piezoresistive silicon sensor
    • Differential pressure range 6 ... 1000 mbar
    • Application for for HVAC-applications
  • Characteristics:
    • Silicon Sensor, HVAC Medical
    • Differential pressure ranges from 0 ... 1.6 mbar up to 0 ... 1000 mbar
    • Accuracy according to IEC 60770: 0.5% FSO BFSL
  • Characteristics:
    • Stainless Steel Sensor, Test Engineering, Machine And Plant Engineering
    • Differential pressure ranges from from 10 mbar up to 20 bar
    • Accuracy according to IEC 60770: 0.35 % FSO
  • Characteristics:
    • Stainless Steel Sensor, Process, Oil And Gas Industry
    • Differential pressure ranges from 1 mbar up to 20 bar
    • Accuracy according to IEC 60770: 0.075 % FSO
  • Features
    • The first transmitter that monitors both dew point and process pressure
    • A simple and convenient transmitter for monitoring of compressed air
    • Highly accurate humidity information thanks to dew point data coupled with live pressure input
    • Compatible with the Vaisala Hand-Held DM70 for easy spot-checking, local display and data logging
    • Pressure: 1 … 12 bar
    • Dew point: -70 … +30 °C (-94 ... +86 °F)
    • Digital output RS-485 with MODBUS
  • Features:
    • Large measuring range
    • High Precision
    • Calibrated with water
    • Display of measurement results in various units
    • Automatic temperature compensation
    • Robust casting
    • Little weight
     
  • Features • Large measuring range • High precision • Calibrated with water • Display of measurement results in various units • Automatic temperature compensation • Robust casing • Little weight
  • Features • Large measuring range • High precision • Calibrated with water • Display of measurement results in various units • Automatic temperature compensation • Robust casing • Little weight
  • Characteristics:
    • Stainless Steel Sensor
    • nominal pressure ranges from 0 ... 100 mbar up to 0 ... 600 bar
    • Accuracy according to IEC 60770: Standard: 0.35 % FSO option: 0.25 % FSO
  • Features
    • Nominal pressure: 0 ... 100 mbar up to 0 ... 40 bar
    • Accuracy: 0.35 % (opt. 0.25 %) FSO
    • Rotatable and configurable display module
    • Indication of measured values on a 4-digit LED display
    • 1, 2 or 4 independent PNP contacts, freely configurable
    • Configurable contacts (switch on / switch off points, hysteresis / window mode, switch on / switch off delay)
    Optional Features
    • IS-version : Ex ia = intrinsically safe for gases
    • Customer specific versions
    • Analogue output
    Areas of Application
    • Medical Technology
    • Food and Beverage
  • Features
    • Nominal pressure: 0 ... 400 mbar up to 0 ... 600 bar
    • Accuracy: 0.5 % FSO
    • Indication of measured values on a 4-digit LED display
    • Rotatable and configurable display module
    • 1, 2 or 4 independent PNP contacts, freely configurable
    Optional Features
    • IS-version: Ex ia = intrinsically safe for gases
    • Pressure port PVDF
    • Customer specific versions
    Areas of Application
    • Mechanical and Plant Engineering
    • Environmental Industry
  • Features
    • Nominal pressure: 0 ... 60 bar up to 0 ... 400 bar
    • Accuracy: 0.5 % FSO
    • 1, 2 or 4 independent PNP contacts, freely configurable
    • Rotatable and configurable display module
    • Indication of measured values on a 4-digit LED display
    Optional Features
    • IS-version - Ex ia = intrinsically safe for gases
    • Cooling element up to 300°C
    • Customer specific versions
    Areas of Application
    • Mechanical and Plant Engineering
    • Food and Beverage
  • Features
    • Nominal pressure: 0 ... 6 bar up to 0 ... 600 bar
    • Accuracy: 0.5 % FSO
    • Indication of measured values on a 4-digit LED display
    • Rotatable and configurable display module
    • 1, 2 or 4 independent PNP contacts, freely configurable
    Optional Features
    • IS-version: Ex ia = intrinsically safe for gases
    • Oxygen application
    • Customer specific versions
    Areas of Application
    • Mechanical and Plant engineering
    • Energy Industry
    • Refrigeration Engineering
    • Medical Technology
    • Utility Vehicles / Mobile Hydraulics
  • Features
    • Nominal pressure: 0 ... 10 mbar up to 0 ... 1000 mbar
    • Accuracy: 0.35 % FSO
    • Indication of measured values on a 4-digit LED display
    • Rotatable and configurable display module
    • 1, 2 or 4 independent PNP contacts, freely configurable
    Optional Features
    • IS-version: Ex ia = intrinsically safe for gases
    • Customer specific versions
    Areas of Application
    • Mechanical and Plant Engineering
    • HVAC
    • Laboratory
  • Features
    • Nominal pressure: 0 ... 600 bar up to 0 ... 2200 bar
    • Accuracy: 0,35 % FSO
    • Indication of measured values on a 4-digit LED display
    • Rotatable and configurable display module
    • 1, 2 or 4 independent PNP contacts, freely configurable
    • Pressure sensor welded
    • Extremely robust and excellent longterm stability
    Optional Features
    • Adjustability of span and offset (4 ... 20 mA / 3-wire)
    • Customer specific versions
    Areas of Application
    • Mechanical and Plant Engineering
    • Utility Vehicles / Mobile Hydraulics
  • Features
    • Nominal pressure: 0 ... 6 bar up to 0 ... 600 bar
    • Accuracy: 0.5 % FSO
    • 1 analog output and up to 2 contacts
    • Display and housing rotatable
    • Perfect for oxygen applications
    Areas of Application
    • Mechanical and Plant Engineering
    • Energy Industry
    • Refrigeration Engineering
    • Medical Technology
    • Utility Vehicles / Mobile Hydraulics
  • Features
    • Nominal pressure: 0 ... 2 bar up to 0 ... 400 bar
    • Accuracy: 1.5 % FSO
    • Display and housing rotatable
    • Up to 2 contacts
    • Configurable via display
    Optional Features
    • Analog output
    Areas of Application
    • Mechanical and Plant Engineering
    • Energy Industry
  • Features
    • Nominal pressure: 0 ... 6 mbar up to 0 ... 1000 mbar
    • Accuracy: 0,35 % FSO
    • Aluminum housing
    • Rotatable and configurable display module
    • 4-digit LED display
    • Suited for non-aggressive gases and compressed air
    Optional Features
    • 1 / 2 PNP contacts
    • customer specific versions
    Areas of Application
    • Mechanical and plant engineering
    • HVAC

Title

Go to Top