- Process Connections with Flush Welded Stainless Steel Diaphragm
- Hygienical Application
- Nominal pressure range from 0...100 mbar Up To 40 bar nominal pressure
- Accuracy according to IEC 60770: 0.1 % FSO
-
Features
- Measures humidity at temperatures up to +180 °C (+356 °F)
- Dew point measurement range−40 … +100 °C (−40 … +212 °F) Td/f
- Dew point measurement accuracy up to ±2 °C (±3.6 °F) Td/f
- Sensor purge provides superior chemical resistance
- Condensation-tolerant
- Modbus RTU over RS-485
- Compatible with Indigo transmitters and Insight PC software
- Traceable calibration certificate
-
Features
- Measures humidity at high temperatures up to +350 °C (+662 °F)
- Dew point measurement range −25 … +100 °C (−13 … +212 °F) Td/f
- Dew point measurement accuracy up to ±2 °C (±3.6 °F) Td/f
- Sensor purge provides superior chemical resistance
- Condensation-tolerant Modbus RTU over RS-485
- Compatible with Indigo transmitters and Insight PC software
- Traceable calibration certificate
-
Features
- Dew point measurement range −70 … +80 °C (−94 … +176 °F) Td/f
- Dew point measurement accuracy up to ±2 °C (±3.6 °F) Td/f
- Sensor purge provides superior chemical resistance
- Tolerates condensation, oils, dust, and most chemicals
- Modbus RTU over RS-485
- Compatible with Indigo transmitters and Insight PC software
- Traceable calibration certificate
-
Features
- Dew point measurement range −70 … +80 °C (−94 … +176 °F) Td/f
- Dew point measurement accuracy up to ±2 °C (±3.6 °F) Td/f
- Operating pressure of probe head 0 … 4 MPa (0 … 40 bar)
- Adjustable installation depth
- Tolerates condensation, oils, dust, and most chemicals
- Sensor purge provides superior chemical resistance
- Modbus RTU over RS-485
- Compatible with Indigo transmitters and Insight PC software
- Traceable calibration certificate
-
Features
- Measures dew point from -70 ... +80 °C (-94 ... +176 °F) with an accuracy of ±2 °C (±3.6 °F)
- Condensation-resistant
- Unique auto-calibration feature maintains accuracy over long term
- Compatible with Vaisala DRYCAP Handheld Dew Point Meter DM70
- Traceable calibration to measurements and analog outputs (certificates included)
- Graphical display and keypad for convenient operation
- Optional alarm relays and mains power supply module
- Up to three analog outputs, RS-232/485, LAN
- Modbus protocol support (RTU/ TCP)
-
Features
- Geiger-Muller counters without return run of counting response.
- Analog indicator of radiation intensity.
- Up to 4096 measurement results recording in the nonvolatile memory with further transfer to the computer through infrared port.
- Review of the recorded measurement results on the display.
- “Precisely” channel with the average result indicated on the display for the fixed measurement time from 1 to 99 minutes.
- Detection of soft beta radiation.
- Programmable threshold levels of gamma and X-ray radiation dose equivalent rate and beta-particles flux density.
- Audio signaling of detected gamma-quanta, beta-particles, and exceeded programmed threshold levels of dose equivalent rate of gamma and X-ray radiation or beta-particles flux density.
- Display backlight.
- Multilevel indication for battery discharge.
-
Features
- Measuring input type : DC current / DC voltage
- More output type:Analog output / Relay / RS-485
- Extraction of square root(Input : voltage, current)
- Option RS-485 communication function can do 10-point linear calibration function
- Signal isolation, preventing noise, filtering function : Provide safe and stable measuring
- Power supply : AC 85 .. 253 V, 50 ... 60 Hz;Auxiliary supply output(DC 18 ... 26 V / 50 mA ) : Use for 2-wire & 3-wire transmitter
- User-friendly, interactive operation interface
- Panel installation, high light red LED display panel, 14.1 mm height of character, 5 digits, -9.9.9.9 ... +9.9.9.9.9, 7-segment display
- Programmable, high safety & stability, fire-proof case, moisture-proof cover
- Plug-in installation design for easy maintenance
-
Features
- High accuracy ±0.1% F.S. ±1 digit
- 2" LCD display, 5-digit display, decimal point configurable.
- Input signals: Current / Voltage
- Output signals: Current / Voltage / Relay / RS-485
- Power supply: AC 90 ... 250 V / DC 24 V
- Auxiliary power: DC 18 ... 26 V / 50 mA
- Square root function for analog signals
- Relay output can be configured for corresponding action modes (Hi / Lo), hysteresis, delay time, and reset delay.
- The linear interpolation function enables the adjustment of non-linear analog input.
-
Features
- High accuracy ±0.1% F.S. ±1 digit
- 2" LCD display, Instantaneous flow : 5-digit, Cumulative flow : 8-digit, decimal point configurable.
- Input signals: Current / Voltage / Frequency / Pulse
- Output signals: Current / Voltage / Relay / RS-485
- Power supply: AC 90 ... 250 V / DC 24 V
- Auxiliary power: DC 18 ... 26 V / 50 mA
- Square root function for analog signals
- Relay output can be configured for corresponding action modes (Hi / Lo), hysteresis, delay time, and reset delay.
- The linear interpolation function enables the adjustment of non-linear analog input.
-
Features
- LED display : Instantaneous flow : 5-digit, Cumulative flow : 8-digit, accuracy ±0.2% F.S.
- Temperature and pressure compensation : Utilizes temperature and pressure measurements for precise density compensation and high accuracy flow calculations, with built-in formulas for various applications.
- RS-485 communication support : Adopts the standard Modbus RTU communication protocol.
- Auxiliary power supply : Provides two sets of DC 24V power supplies to simplify field wiring.
- Isolation design : Ensures mutual isolation between input, output, power, and communication interfaces.
-
Features
- Measuring input type : DC current / DC voltage
- Multiple output type : RELAY / RS-485 (Option)
- Filtering function, provide safe and stable measuring
- Power supply : AC 90 ... 250 V / 50 ... 60 Hz, DC 24 V±10% Auxiliary supply output (DC 18 ... 26 V / 50 mA), use for 2-wire transmitter
- Panel installation, high light red LED display panel, 14.1 mm height of character, 4 digits(-1999 ... +9999), 7-segment display
- Programmable, high safety & stability, fire-proof case, moisture-proof cover
- Plug-in installation design for easy maintenance
-
Features
- The first transmitter that monitors both dew point and process pressure
- A simple and convenient transmitter for monitoring of compressed air
- Highly accurate humidity information thanks to dew point data coupled with live pressure input
- Compatible with the Vaisala Hand-Held DM70 for easy spot-checking, local display and data logging
- Pressure: 1 … 12 bar
- Dew point: -70 … +30 °C (-94 ... +86 °F)
- Digital output RS-485 with MODBUS
-
Features
- Nominal pressure: 0 ... 100 mbar up to 0 ... 40 bar
- Accuracy: 0.35 % (opt. 0.25 %) FSO
- Rotatable and configurable display module
- Indication of measured values on a 4-digit LED display
- 1, 2 or 4 independent PNP contacts, freely configurable
- Configurable contacts (switch on / switch off points, hysteresis / window mode, switch on / switch off delay)
- IS-version : Ex ia = intrinsically safe for gases
- Customer specific versions
- Analogue output
- Medical Technology
- Food and Beverage
-
Features
- Nominal pressure: 0 ... 400 mbar up to 0 ... 600 bar
- Accuracy: 0.5 % FSO
- Indication of measured values on a 4-digit LED display
- Rotatable and configurable display module
- 1, 2 or 4 independent PNP contacts, freely configurable
- IS-version: Ex ia = intrinsically safe for gases
- Pressure port PVDF
- Customer specific versions
- Mechanical and Plant Engineering
- Environmental Industry
-
Features
- Nominal pressure: 0 ... 60 bar up to 0 ... 400 bar
- Accuracy: 0.5 % FSO
- 1, 2 or 4 independent PNP contacts, freely configurable
- Rotatable and configurable display module
- Indication of measured values on a 4-digit LED display
- IS-version - Ex ia = intrinsically safe for gases
- Cooling element up to 300°C
- Customer specific versions
- Mechanical and Plant Engineering
- Food and Beverage
-
Features
- Nominal pressure: 0 ... 6 bar up to 0 ... 600 bar
- Accuracy: 0.5 % FSO
- Indication of measured values on a 4-digit LED display
- Rotatable and configurable display module
- 1, 2 or 4 independent PNP contacts, freely configurable
- IS-version: Ex ia = intrinsically safe for gases
- Oxygen application
- Customer specific versions
- Mechanical and Plant engineering
- Energy Industry
- Refrigeration Engineering
- Medical Technology