- 60dB Dynamic Space in each Range
- Time weighting Fast / Slow
- AC/DC signal output
- 1ms Peak Hold Function
- Max/Min Function
- ½ inch electret condenser microphone (with metal housing)
- Bargraph indication
- Patented
-
Features:
- User Adjustable Parameter For Special Light Source
- Measure Most Popular Light Sources In Lux or Fc
- Removable Probe For Easy Access To The Source
- Cosine And Color Corrected Measurements
- Built-in Sensor With Protective Cover
- Min/Max Average And Auto Power Off
- Large LCD Display For Easy Reading
- Max/Min Function
-
Features
- 0.0 to 14.0 full pH range
- Auto-calibration & auto-buffer recognition
- Automatic temperature compensation
- IP67 waterproof – tester floats on water for easy retrieval
- Long sensor life – no need to change sensors
- Click-lock battery compartment requires no tools for battery replacements
- Hold function freezes reading temporarily for ease of recording
- Sensor protective cap that doubles up as a container for samples or calibration solution
-
Features
- Measurement range from 0 to 19.99 mS/cm
- Auto-calibration & auto-buffer recognition
- Automatic temperature compensation
- IP67 waterproof – tester floats on water for easy retrieval
- Long sensor life – no need to change sensors
- Click-lock battery compartment requires no tools for battery replacements
- Hold function freezes reading temporarily for ease of recording
- Sensor protective cap that doubles up as a container for samples or calibration solution
-
Features
- Measurement range from 0 to 10.00 ppt
- Auto-calibration & auto-buffer recognition
- Automatic temperature compensation
- IP67 waterproof – tester floats on water for easy retrieval
- Long sensor life – no need to change sensors
- Click-lock battery compartment requires no tools for battery replacements
- Hold function freezes reading temporarily for ease of recording
- Sensor protective cap that doubles up as a container for samples or calibration solution
-
Features
- LED digital display and operation panel
- Automatic swing function. Low/ High air speed
- Purification Function: Active Carbon
- Both bucket and continuous hose drain
- Low temperature auto-defrost
- 1-24 hours timer on timer off
- Automatic water full alarm and stop
- Power memory and restart function function
- Universal castors, eave to move around
-
Features
- LED digital display and operation panel
- Washable coarse air filter, easy to maintain
- PGMCC (R410a) brand compressor
- Both bucket and continuous hose drain
- Low temperature auto-defrost
- 1-24 hours timer on and timer off
- Automatic water full alarm and stop
- Universal castors, eave to move around
-
Features
- LED digital display and operation panel
- Washable coarse air filter, easy to maintain
- PGMCC (R410a) brand compressor
- Both bucket and continuous hose drain
- Low temperature auto-defrost
- 1-24 hours timer on and timer off
- Automatic water full alarm and stop
- Universal castors, eave to move around
-
Features
- LED digital display and operation panel
- Washable coarse air filter, easy to maintain
- PGMCC (R410a) brand compressor
- Both bucket and continuous hose drain
- Low temperature auto-defrost
- 1-24 hours timer on and timer off
- Automatic water full alarm and stop
- Universal castors, eave to move around
-
Product Features
- LED Digital display, timer on and off, auto-restart function
- 304 stainless steel mist maker, durable and efficient
- Low noise water proof fan, shield protected
- Superior transformer, ensure long time
- Water lack protection, manual/ auto water supply
- Compact design. easy to install and maintain
- Bottom castors, easy to move about
-
Features
- Low running and maintenance costs
- High evaporation efficiency, low pressure drop
- Now water treatment required, no water carry-over
- Compact design, no risk or over-saturation
- Self-clean function, low scaling safe and hygiene
- LGE digital display timer on and off, auto-restart function
- Water-lack protection, manual/ auto water supply
-
Characteristic
- Low pressure humidifiers work by spraying water through centrifugal force. Unlike high-pressure systems, the water is sprayed into the room in the form of a very fine mist (water droplets below 20 μ) which evaporates immediately - resulting in minimal limescale build-up.
- The humidification capacity is constant and independent of temperature and humidity level.
- Control of an external mechanical hygrostat (option)
- Adjustable capacity from 1 to 7 l / h
- It reduces electrostatic charges
- IP 56
-
Features
- Big display with luminescent backlight.
- Simultaneous indication of units of measurement, measurement errors, threshold level and real time on the display.
- Analog ten-segment indicator of registered radiation intensity.
- Ability to perform measurements with a preset error.
- Four-level indication of battery discharge.
- Built-in memory which allows storing up to 1200 measurements.
- Mode of PC connection via Bluetooth.
- Five independent measuring channels with alternate indication of data on the single liquid crystal display.
- Built-in gamma, beta sensitive Geiger-Muller counter.
- Prompt evaluation of gamma background within 10 seconds.
- Automatic subtraction of gamma background at measurement of beta contamination.
- Measurement results averaging, manually and automatically interrupted.
- Automatic setting of measurement intervals and ranges.
- Audio, vibration and vibration-audio alarm of each detected gamma-quantum or beta-particle that can be switched off.
- Two-tone audio, vibration and vibration-audio alarm of exceeded programmed threshold levels.
- Two AAA batteries.
- Shock-resistant body.
- Small weight and dimensions
-
Features
- Alpha-beta-gamma-sensitive Geiger-Mueller counter with mica window.
- Energy-compensating filter, which allows to obtain a reliable energy dependence of the radiometer readings when measuring photon ionizing radiation in the energy range from 12 KeV to 3 MeV.
- Large display with luminescent backlight, which provides simultaneous display of measurement units, measurement errors, threshold level, real time; and an analog indicator of instantaneous radiation intensity.
- Ability to perform measurements with a preset error.
- Prompt evaluation of gamma background within 10 seconds.
- Automatic subtraction of gamma radiation component when measuring beta radiation parameters.
- Automatic subtraction of gamma and beta radiation components when measuring alpha radiation parameters.
- Programming of threshold levels of the alarm system activation for each parameter of measured radiation.
- Automatic setting of measurement intervals and ranges.
- Audio signaling of each registered gamma quantum, alpha or beta particle with the possibility of its deactivation.
- Two-tone audio alarm of exceeded programmed threshold levels.
- Recording in non-volatile memory up to 1000 measurement results.
- Viewing the measurement results previously recorded in non-volatile memory on the indicator, as well as transfer the information to a personal computer via Bluetooth.
- Two AAA batteries.
- Four-level indication of the battery discharge.
- New RadReader software has been developed to work with the device.
-
Features
- Geiger-Muller counters without return run of counting response.
- Analog indicator of radiation intensity.
- Up to 4096 measurement results recording in the nonvolatile memory with further transfer to the computer through infrared port.
- Review of the recorded measurement results on the display.
- “Precisely” channel with the average result indicated on the display for the fixed measurement time from 1 to 99 minutes.
- Detection of soft beta radiation.
- Programmable threshold levels of gamma and X-ray radiation dose equivalent rate and beta-particles flux density.
- Audio signaling of detected gamma-quanta, beta-particles, and exceeded programmed threshold levels of dose equivalent rate of gamma and X-ray radiation or beta-particles flux density.
- Display backlight.
- Multilevel indication for battery discharge.
-
Features
- New generation high sensitivity CsI scintillation detectors of gamma and LiI of neutron radiation with solid state (silicon) photomultiplier.
- Color display with high resolution.
- Integrated GPS/GLONASS-receiver.
- No “microphone effect”.
- High thermal stability.
- Audio and vibration alarm of threshold levels exceeding.
- Threshold alarm system with four independent threshold levels: – search threshold level (threshold level of count rate from the detector photon and neutron ionizing radiation); – safety threshold level (threshold level of photon ionizing radiation DER); – accumulated dose threshold level.
- Light color alarm (indication) of threshold levels exceeding (gamma radiation – red color, neutron – blue) and visual alarm on the side of the device.
- The dosimeter communicates with a PC via USB-port.
- Powered by built-in lithium polymer storage battery that can be charged via USB-cable.Ingress protection rating IP67.
-
Features
- New generation high sensitivity CsI scintillation detectors of gamma and LiI of neutron radiation with solid state (silicon) photomultiplier.
- Color display with high resolution.
- Storage and transfer of 250 complete gamma radiation spectra.
- Powerful CPU and improved algorithms for spectra processing.
- New software for detailed laboratory research and spectra processing.
- Integrated GPS/GLONASS-receiver.
- No “microphone effect”.
- High thermal stability.
- Powered by built-in lithium polymer storage batteries that can be charged via USB-cable.
- The dosimeter communicates with a PC via USB-port.
- Real-time identification of spectra.
- Identification of radionuclides with specification of the categories they belong to (in compliance with IAEA requirements): – medical radionuclides: 18F, 67Ga, 51Cr, 75Se, 89Sr, 99Mo, 99mTc, 103Pd, 111In, 123I, 125I, 131I, 153Sm, 201Tl, 133Хе; – industrial radionuclides: 57Co, 60Co, 133Ba, 137Cs, 192Ir,152Eu, 22Na, 241Am; – special nuclear materials: 233U, 235U, 237Np, Pu [Reactor grade plutonium (more than 6% 240Pu)]; – naturally occurring radioactive materials: 40K, 138La, 226Ra, 232Th-decay series, 238U-decay series. Note. The list of nuclides the device is able to identify may be extended if needed.
- Threshold alarm system with four independent threshold levels: – search threshold level (threshold level of count rate from the detector photon and neutron ionizing radiation); – safety threshold level (threshold level of photon ionizing radiation DER); – accumulated dose threshold level.
- Light color alarm (indication) of threshold levels exceeding (gamma radiation – red color, neutron – blue) and visual alarm on the side of the device.
- Ingress protection rating IP67.Sample of Th232 (Thorium) is included into the Delivery kit for detector age compensation.
-
Features
- Possibility to measure ambient dose equivalent rate (DER) of gamma radiation with the detector which is built in the control panel.
- Automatic selection between measurement intervals and ranges.
- Audio signalling of each registered gamma-quantum or beta particle.
- Backlit indicator and control keys for operation in the dark.
- Rechargeable lithium-ion battery charging by the built-in charger from: – internal solar battery; – 12 V automobile battery; – 220 V/50 Hz mains power using a voltage converter.
- Multilevel indication of battery discharge.
- Operates under conditions involving atmospheric precipitation, dusty atmosphere (IP67).
- Analog indicator of radiation intensity.
- Logging of up to 1500 measurement results tagged to location coordinates in the nonvolatile memory via infrared port to the PC (built-in GPS/GLONASS receiver).
- Viewing of logged measurement results on the display.
- Easy to operate even if wearing personal protection – rubber gloves.
- Wide operating temperature range – from -30…+55°C.
- Display temperature resistance – +95°C.
- Gas-discharge Geiger-Muller counters without return run of counting response
- Silicon beta radiation detector
-
Features
- Remote continuous computer-aided radiation monitoring of the environment.
- Receipt of measurement results of ambient dose equivalent rate (DER) from the BDBG-09 detection units, ambient temperature values, and service information (serial number, results of self-testing) and data transfer to the server by GPRS channel.
- Display of measurement results in real-time mode, in numerical and/or graphical form, obtained from monitoring points located at a considerable distance.
- Possibility to set a different threshold level of alarm for each of the monitoring points.
- Generation of emergency and warning notifications when DER measurement results of the specified threshold levels are exceeded.
- Storage of measurement results received from monitoring points, emergency and warning notifications to the database.
- Display of saved measurement results from monitoring points, emergency and warning notifications recorded in the database.
- Storage of information received from the detection units BDBG-09 when disconnected from a remote fixed server, and its subsequent transfer when reconnected.
- Possibility to expand functionality through the integration of devices, equipped with RS-485 interface (e.g., weather stations or other types of detectors with the appropriate adaptation of application software).
- Possibility to connect the IT-09 (T) panel directly in the monitoring point installation for the radiation situation assessment.
- Autonomous operation of monitoring points without an external supply voltage of 220 V. The system is equipped with an uninterruptible power supply.
- Use of SCADA software capabilities and benefits when using a server component, including report generation and printing.