Loading...
  • Characteristics
    • Process Connections with Flush Welded Stainless Steel Diaphragm
    • Hygienical Application
    • Nominal pressure  range from 0...100 mbar Up To 40 bar nominal pressure
    • Accuracy according to IEC 60770: 0.1 % FSO
  • Characteristics
    • Stainless Steel Sensor
    • Universal Application
    • Nominal pressure from 0 ... 100 bar up to 0 ... 600 bar
    • Accuracy according to IEC 60770: standard: 0.35 % FSO option: 0.25 / 0.1 % FSO
  • Characteristics
    • Thinfilm Sensor
    • Nominal pressure range from 0 ... 600 bar up to 0 ... 2200 bar
    • Accuracy according to IEC 60770: 0.35 % FSO
    • Preferred areas of use for Plant & Mechanical Engineering
  • Characteristics
    • Thinfilm Sensor
    • Nominal pressure ranges from 0 ... 600 bar up to 0 ... 2200 bar
    • Accuracy according to IEC 60770: 0.1 % FSO
    • Preferred areas of use for Welded, Plant And Machine Engineering
       
  • Characteristics
    • Welded, Dry Stainless Steel Sensor
    • Nominal pressure range from 0 ... 6 bar up to 0 ... 600 bar
    • Accuracy according to IEC 60770: 0.5 % FSO
    • Preferred areas of use for Medical Technology
  • Characteristics
    • Stainless Steel Sensor Flush Version G 1/4
    • Nominal pressure ranges from 0 ... 60 bar to 0 ... 600 bar
    • Accuracy according to IEC 60770: 0.35 % FSO
  • Characteristics
    • Stainless Steel Sensor, Without Media Isolation, HVAC
    • Nominal pressure ranges from 0 ... 10 mbar up to 0 ... 1000 mbar
    • Accuracy according to IEC 60770: 0.35 % FSO
  • Characteristics
    • Stainless Steel Sensor
    • Nominal pressure ranges from
    • Accuracy according to IEC 60770: standard: 0.35 % FSO option: 0.25 % FSO
  • Characteristics
    • Stainless Steel Sensor
    • Nominal pressure from 0 ... 400 mbar up to 0 ... 600 bar
    • accuracy according to IEC 60770: 0.1 % FSO
    • Preferred areas of use for Process, Oil And Gas Industry
    • Communication interface for adjusting of offset, span and damping
  • Features
    • Measures humidity at temperatures up to +180 °C (+356 °F)
    • Dew point measurement range−40 … +100 °C (−40 … +212 °F) Td/f
    • Dew point measurement accuracy up to ±2 °C (±3.6 °F) Td/f
    • Sensor purge provides superior chemical resistance
    • Condensation-tolerant
    • Modbus RTU over RS-485
    • Compatible with Indigo transmitters and Insight PC software
    • Traceable calibration certificate
     
  • Features
    • Measures humidity at high temperatures up to +350 °C (+662 °F)
    • Dew point measurement range −25 … +100 °C (−13 … +212 °F) Td/f
    • Dew point measurement accuracy up to ±2 °C (±3.6 °F) Td/f
    • Sensor purge provides superior chemical resistance
    • Condensation-tolerant Modbus RTU over RS-485
    • Compatible with Indigo transmitters and Insight PC software
    • Traceable calibration certificate
     
  • Features
    • Dew point measurement range −70 … +80 °C (−94 … +176 °F) Td/f
    • Dew point measurement accuracy up to ±2 °C (±3.6 °F) Td/f
    • Sensor purge provides superior chemical resistance
    • Tolerates condensation, oils, dust, and most chemicals
    • Modbus RTU over RS-485
    • Compatible with Indigo transmitters and Insight PC software
    • Traceable calibration certificate
  • Features
    • Dew point measurement range −70 … +80 °C (−94 … +176 °F) Td/f
    • Dew point measurement accuracy up to ±2 °C (±3.6 °F) Td/f
    • Operating pressure of probe head 0 … 4 MPa (0 … 40 bar)
    • Adjustable installation depth
    • Tolerates condensation, oils, dust, and most chemicals
    • Sensor purge provides superior chemical resistance
    • Modbus RTU over RS-485
    • Compatible with Indigo transmitters and Insight PC software
    • Traceable calibration certificate
  • Features
    • High accuracy ±1°C (±1.8°F) in the measurement range of refrigerant dryers
    • Low power requirements, 10 .... 28 VDC
    • Optional LED warning light
    • Optional loop powered display, Nokeval 301
  • Features
    • Vaisala DRYCAP technology with a polymer sensor
    • Measures dew point down to -80 °C (-112 °F)
    • Withstands condensation
    • Traceable calibration (certificate included)
    • Applications: dry chambers, dry gases, semiconductor manufacturing, research and testing, and compressed air
  • Features
    • Measures dew point from -70 ... +80 °C (-94 ... +176 °F) with an accuracy of ±2 °C (±3.6 °F)
    • Condensation-resistant
    • Unique auto-calibration feature maintains accuracy over long term
    • Compatible with Vaisala DRYCAP Handheld Dew Point Meter DM70
    • Traceable calibration to measurements and analog outputs (certificates included)
    • Graphical display and keypad for convenient operation
    • Optional alarm relays and mains power supply module
    • Up to three analog outputs, RS-232/485, LAN
    • Modbus protocol support (RTU/ TCP)
  • Features
    • DMT345 measures humidity at temperatures up to 180 °C (356 °F)
    • DMT346 measures humidity at temperatures up to 350 °C (+662 °F)
    • Dew point accuracy ±2 °C (±3.6 °F)
    • Condensation-resistant
    • Unique auto-calibration feature
    • Analog outputs, RS-232/485, WLAN/LAN
    • Modbus protocol support (RTU/ TCP)
  • Features
    • Geiger-Muller counters without return run of counting response.
    • Analog indicator of radiation intensity.
    • Up to 4096 measurement results recording in the nonvolatile memory with further transfer to the computer through infrared port.
    • Review of the recorded measurement results on the display.
    • “Precisely” channel with the average result indicated on the display for the fixed measurement time from 1 to 99 minutes.
    • Detection of soft beta radiation.
    • Programmable threshold levels of gamma and X-ray radiation dose equivalent rate and beta-particles flux density.
    • Audio signaling of detected gamma-quanta, beta-particles, and exceeded programmed threshold levels of dose equivalent rate of gamma and X-ray radiation or beta-particles flux density.
    • Display backlight.
    • Multilevel indication for battery discharge.
  • Characteristics
    • Piezoresistive silicon sensor
    • Differential pressure range 6 ... 1000 mbar
    • Application for for HVAC-applications
  • Characteristics:
    • Silicon Sensor, HVAC Medical
    • Differential pressure ranges from 0 ... 1.6 mbar up to 0 ... 1000 mbar
    • Accuracy according to IEC 60770: 0.5% FSO BFSL
  • Characteristics:
    • Stainless Steel Sensor, Test Engineering, Machine And Plant Engineering
    • Differential pressure ranges from from 10 mbar up to 20 bar
    • Accuracy according to IEC 60770: 0.35 % FSO
  • Characteristics:
    • Stainless Steel Sensor, Process, Oil And Gas Industry
    • Differential pressure ranges from 1 mbar up to 20 bar
    • Accuracy according to IEC 60770: 0.075 % FSO
  • Features
    • The first transmitter that monitors both dew point and process pressure
    • A simple and convenient transmitter for monitoring of compressed air
    • Highly accurate humidity information thanks to dew point data coupled with live pressure input
    • Compatible with the Vaisala Hand-Held DM70 for easy spot-checking, local display and data logging
    • Pressure: 1 … 12 bar
    • Dew point: -70 … +30 °C (-94 ... +86 °F)
    • Digital output RS-485 with MODBUS
  • Features:
    • Large measuring range
    • High Precision
    • Calibrated with water
    • Display of measurement results in various units
    • Automatic temperature compensation
    • Robust casting
    • Little weight
     
  • Features • Large measuring range • High precision • Calibrated with water • Display of measurement results in various units • Automatic temperature compensation • Robust casing • Little weight
  • Features • Large measuring range • High precision • Calibrated with water • Display of measurement results in various units • Automatic temperature compensation • Robust casing • Little weight
  • Characteristics:
    • Stainless Steel Sensor
    • nominal pressure ranges from 0 ... 100 mbar up to 0 ... 600 bar
    • Accuracy according to IEC 60770: Standard: 0.35 % FSO option: 0.25 % FSO
  • Features
    • Nominal pressure: 0 ... 100 mbar up to 0 ... 40 bar
    • Accuracy: 0.35 % (opt. 0.25 %) FSO
    • Rotatable and configurable display module
    • Indication of measured values on a 4-digit LED display
    • 1, 2 or 4 independent PNP contacts, freely configurable
    • Configurable contacts (switch on / switch off points, hysteresis / window mode, switch on / switch off delay)
    Optional Features
    • IS-version : Ex ia = intrinsically safe for gases
    • Customer specific versions
    • Analogue output
    Areas of Application
    • Medical Technology
    • Food and Beverage
  • Features
    • Nominal pressure: 0 ... 400 mbar up to 0 ... 600 bar
    • Accuracy: 0.5 % FSO
    • Indication of measured values on a 4-digit LED display
    • Rotatable and configurable display module
    • 1, 2 or 4 independent PNP contacts, freely configurable
    Optional Features
    • IS-version: Ex ia = intrinsically safe for gases
    • Pressure port PVDF
    • Customer specific versions
    Areas of Application
    • Mechanical and Plant Engineering
    • Environmental Industry
  • Features
    • Nominal pressure: 0 ... 60 bar up to 0 ... 400 bar
    • Accuracy: 0.5 % FSO
    • 1, 2 or 4 independent PNP contacts, freely configurable
    • Rotatable and configurable display module
    • Indication of measured values on a 4-digit LED display
    Optional Features
    • IS-version - Ex ia = intrinsically safe for gases
    • Cooling element up to 300°C
    • Customer specific versions
    Areas of Application
    • Mechanical and Plant Engineering
    • Food and Beverage
  • Features
    • Nominal pressure: 0 ... 6 bar up to 0 ... 600 bar
    • Accuracy: 0.5 % FSO
    • Indication of measured values on a 4-digit LED display
    • Rotatable and configurable display module
    • 1, 2 or 4 independent PNP contacts, freely configurable
    Optional Features
    • IS-version: Ex ia = intrinsically safe for gases
    • Oxygen application
    • Customer specific versions
    Areas of Application
    • Mechanical and Plant engineering
    • Energy Industry
    • Refrigeration Engineering
    • Medical Technology
    • Utility Vehicles / Mobile Hydraulics
  • Features
    • Nominal pressure: 0 ... 10 mbar up to 0 ... 1000 mbar
    • Accuracy: 0.35 % FSO
    • Indication of measured values on a 4-digit LED display
    • Rotatable and configurable display module
    • 1, 2 or 4 independent PNP contacts, freely configurable
    Optional Features
    • IS-version: Ex ia = intrinsically safe for gases
    • Customer specific versions
    Areas of Application
    • Mechanical and Plant Engineering
    • HVAC
    • Laboratory
  • Features
    • Nominal pressure: 0 ... 600 bar up to 0 ... 2200 bar
    • Accuracy: 0,35 % FSO
    • Indication of measured values on a 4-digit LED display
    • Rotatable and configurable display module
    • 1, 2 or 4 independent PNP contacts, freely configurable
    • Pressure sensor welded
    • Extremely robust and excellent longterm stability
    Optional Features
    • Adjustability of span and offset (4 ... 20 mA / 3-wire)
    • Customer specific versions
    Areas of Application
    • Mechanical and Plant Engineering
    • Utility Vehicles / Mobile Hydraulics
  • Features
    • Nominal pressure: 0 ... 6 bar up to 0 ... 600 bar
    • Accuracy: 0.5 % FSO
    • 1 analog output and up to 2 contacts
    • Display and housing rotatable
    • Perfect for oxygen applications
    Areas of Application
    • Mechanical and Plant Engineering
    • Energy Industry
    • Refrigeration Engineering
    • Medical Technology
    • Utility Vehicles / Mobile Hydraulics
  • Features
    • Nominal pressure: 0 ... 2 bar up to 0 ... 400 bar
    • Accuracy: 1.5 % FSO
    • Display and housing rotatable
    • Up to 2 contacts
    • Configurable via display
    Optional Features
    • Analog output
    Areas of Application
    • Mechanical and Plant Engineering
    • Energy Industry
  • Features
    • Nominal pressure: 0 ... 6 mbar up to 0 ... 1000 mbar
    • Accuracy: 0,35 % FSO
    • Aluminum housing
    • Rotatable and configurable display module
    • 4-digit LED display
    • Suited for non-aggressive gases and compressed air
    Optional Features
    • 1 / 2 PNP contacts
    • customer specific versions
    Areas of Application
    • Mechanical and plant engineering
    • HVAC
  • Features
    • Nominal pressure: 0 ... 100 mbar up to 0 ... 600 bar
    • Accuracy: 0,35 % FSO
    • Analog output (optional): 4 ... 20 mA or 0 ... 10 V
    • Indication of measured values on a 4-digit LED display
    • Parametrization by IO-Link or set menu system (VDMA-conform)
    • Rotatable and configurable display
    • 2 contacts
    Optional Features
    • different mechanical connections
    • customer specific versions
    Areas of Application
    • Mechanical and Plant Engineering
    • Hydraulics
    • Packaging and Paper Industry
     
  • Characteristics
    • nominal pressure ranges from 0 ... 1 bar up to 0 ... 10 bar also -1 ... 0 bar
    •  1 or 2 contacts
    • Compact design
    • Configurable via PC or programming device P6
    Applications
    • Pneumatic
    • Vacuum technology
  • Features
    • Nominal pressure: 0 ... 100 mbar up to 0 ... 600 bar
    • Accuracy: 0.35 % (opt. 0.25 %) FSO
    • Indication of measured values on a 4-digit LED display
    • Rotatable and configurable display module
    • 1 or 2 independent PNP contacts, freely configurable
    Optional Features
    • IS-version - Ex ia = intrinsically safe for gases and dust
    • Pressure sensor welded
    • Customer Specific Versions
    Areas of Application
    •  Mechanical and plant engineering
    •  HVAC
    • Environmental industry
  • Features
    • Nominal pressure: 0 ... 100 mbar up to 0 ... 40 bar
    • Accuracy: 0.35 % (opt. 0.25 %) FSO
    • 1 or 2 independent PNP contacts, freely configurable
    • Indication of measured values on a 4-digit LED display
    • Rotatable and configurable display module
    • Hygienic process connections with flush stainless steel diaphragm
    • Configurable contacts (switch on / switch off points, hysteresis / window mode, switch on / switch off delay)
    Optional Features
    • IS-version - Ex ia = intrinsically safe for gases
    • Analog Output - 2-wire: 4 ... 20 mA, 3-wire: 4 ... 20 mA with Turn Down 1:5, 0 ... 10
    • Customer Specific Versions
    Areas of Application
    • Medical Technology
    • Food and Beverage
  • Features
    • nominal pressure: 0 ... 400 mbar up to 0 ... 600 bar
    • accuracy: 0.5 % FSO
    • rotatable and configurable display module
    • indication of measured values on a 4-digit LED display
    • 1 or 2 independent PNP contacts, freely configurable
     Optional Features
    • IS-version Ex ia = itrinsically safe for gases
    • pressure port PVDF
    • customer specific versions
    Areas of Application
    • Mechanical and plant engineering mechanical and plant engineering
    • Environmental industry environmental industry
     
  • Features
    • Nominal pressure: 0 ... 2 bar up to 0 ... 400 bar
    • Accuracy: 1 % FSO
    • 1 or 2 contacts
    • Configurable via PC or programming device P6
    • Diaphragm ceramic (96 %)
    Optional Features
    • Oil- and grease free application
    Areas of Application
    • Mechanical and plant engineering
    • Energy Industry
  • Features
    • Digtize designing suitable for measuring rotational speed and observing stationary images
    • Button operation, widely measurement range and high accuracy
    • Automatic record the last speed value when the power is turned off
    • Three complete setup memory storage
     
  • Features:
    • Digtize designing suitable for measuring rotational speed and observing stationary images
    • Button operation, widely measurement range and high accuracy
    • Automatic record the last speed value when the power is turned off
    • Three complete setup memory storage
     
  • Features:
    • Digtize designing suitable for measuring rotational speed and observing stationary images
    • Button operation, widely measurement range and high accuracy
    • Automatic record the last speed value when the power is turned off
    • Three complete setup memory storage
     
  • Features:
    • Digitize designing suitable for measuring rotational speed and observing stationary images
    • Button operation, widely measurement range and high accuracy
    • Automatic record the last speed value when the power is turned off
    • Three complete setup memory storage
    • Timer function 1, 5, 10 minutes or sustained (DS-9000 only)
     
  • Features
    • °F/°C selectable
    • Min/Max memory stores lowest/highest readings
    • Automatic calibration feature
    • IP65 Waterproof
    • Reduced Tip Probe
    • Complies with FDA Food Code 4-203.11
  • Features
    • NSF certified
    • °F/°C selectable
    • Min/Max memory stores lowest/highest readings
    • Automatic calibration feature
    • IP65 Waterproof housing
    • Small-diameter probe ideal for measuring temperature of "thin mass" food such as meat patties and chicken/fish fillets (FDA Food Code 4-302.12 (B).
  • Features
    • NSF Certified
    • Sealed anti-microbial unibody construction
    • Automatic calibration feature
    • Needle tip ideal for measuring temperature of thin mass foods such as meat patties, chicken and fish fillets, per FDA Food Code 4-302.12 (B)
    • Fast response time
    • Highly visible dual scale jumbo LCD display
    • IP56 waterproof, sanitizable, dirt and grease resistant
    • Automatic shut off saves battery
    • °F/°C selectable
  • Feature
    • Auto-calibration
    • NSF Certified
    • °C/°F selectable
    • Min/Max memory
    • IP65 waterproof/plastic protective heat shield with velcro strap
    • Use to comply with FDA Food Code 4-703.11 (B)
  • Features
    • Measuring range from -58°F to 158°F (-50°C to 70°C)
    • Highly accurate up to ± 1°F (±0.5°C)
    • High/low alarm settings
    • Minimum/Maximum memory stores lowest/highest readings
    • Stereo jack gold plated connector reduces faulty readings
    • Jumbo LCD
    • Switchable °F/°C scale
    • Blunt probe sensor with 10 foot (3 meter) strain resistant cable
    • Strong magnetic attachment and fold-away stand
    • Retains settings during battery swap
    • Configurable delay alarms with audible buzzer and/or flashing light
    • More than 1 year of continuous monitoring
  • Features
    • High/low alarm setting
    • Glycol buffered probe emulates products and prevents false alarms during normal use
    • Gold plated stereo jack connector reduces faulty readings
    • Minimum/Maximum memory stores lowest/highest readings
    • Jumbo LCD
    • Switchable °F/°C scale
    • Strong Magnetic attachment and fold-away stand
    • Retains settings during battery replacement
    • Configurable delay alarms with audible buzzer
    • More than 1 year of continuous monitoring
    • Ideal for monitoring vaccines and common fluids stored in refrigerators, freezers, and cold holding display cases
    • High/low alarm setting
    • Glycol buffered probe emulates products and prevents false alarms during normal use
    • Gold plated stereo jack connector reduces faulty readings
    • Minimum/Maximum memory stores lowest/highest readings
    • Jumbo LCD
    • Switchable °F/°C scale
    • Strong Magnetic attachment and fold-away stand
    • Retains settings during battery replacement
    • Configurable delay alarms with audible buzzer
    • More than 1 year of continuous monitoring
    • Ideal for monitoring vaccines and common fluids stored in refrigerators, freezers, and cold holding display cases
  • Features
    • Monitor vaccines in ultra-low temperatures
    • Ideal for storage and transport with dry ice
    • Minimum/Maximum memory for lowest and highest readings
    • High and Low Alarms with audible buzzer and flashing red light
    • Detachable external sensor with gold plated stereo jack connector
    • Jumbo LCD
    • Selectable ºC/ºF temperature scales
    • Non-volatile memory retains settings during battery replacement
    • Remaining battery indicator
    • Mounts to vertical surfaces with strong built-in magnets
    • Foldable stand for placement on flat surfaces
    • Lightweight, compact, 2-in-1 design
    • Thermocouple probe for internal product temperature
    • Infrared for instant non-contact surface measurement
    • Multi-beam laser for accurate targeting
    • Ideal for extremely hot areas, moving objects, hard to reach places
    • Green backlight indicates HACCP food safety zone
    • Red backlight indicates HACCP danger zone
    • Min/Max memory in IR mode
    • NSF Certified, NIST traceable
    • Fast 3 second thermocouple reading
    • Instant infrared reading
    • Low battery indicator
  • Features
    • New 2 part document for ease of use
    • New improved pull tab designed to make it easier to START
    • Dual scale °F/°C chart
    • Bilingual operation instructions
    • Various models ranging from 5-Day to 90-Day transit periods
    • Available in three temperature ranges
    • Patented design guarantees recording trace stops at end of trip
    • Vented case for superior air circulation and faster temperature response
    • Serial number on each unit for traceability
  • Features
    • Single-use
    • Large, easy to read LCD display
    • Trip history statistics available on LCD
    • USB Connection, no cradle reader or adapter needed
    • Patented Shadow Log feature guarantees data even if the operator fails to start the unit
  • Features
    • Two channel logging capability
    • Includes one sensor with blunt tip probe
    • Optional second sensor: 20963 (blunt tip) or 20964 (glycol bottle)
    • Data transmitted through cellular connections or Wi-Fi
    • Cloud-based application for system administration, data collection and analysis
  • Features
    • Monitor ultra low temperature during storage and transport using dry ice or liquid nitrogen
    • External sensor tracks temperature of products
    • No need to open shipping box or vehicle door to read data
    • Location data plotted on Google Maps
    • Light sensor alert when box or vehicle doors open for added security
    • Trip information automatically uploads to 24/7 cloud service
    • On-board memory records data every 10 minutes
    • Option to download PDF report to PC with USB cable
    • 12-month battery shelf life
  • Features
    • Monitor ultra low temperature during storage and transport using dry ice or liquid nitrogen
    • External sensor tracks temperature of products
    • No need to open shipping box or vehicle door to read data
    • Location data plotted on Google Maps
    • Data is automatically uploaded to 24/7 cloud service
    • On-board memory records data every 10 minutes
    • Option to download PDF report to PC with USB cable
    • Optional Bluetooth printer provides paper chart on demand
  • Features
    • Has compact, convenient single-use design that requires no downloads
    • Includes standard USB connector that needs no special reading device
    • Creates PDF and CSV reports with F/C readings automatically
    • Scales reported data automatically to graphs for easy visualization
    • Features peel-away barcode with trip number for fuss-free traceability
    • Comes in sealed, waterproof plastic envelope
  • Features
    • Compact single-use electronic indicator
    • Monitor vaccines during storage and transport
    • Refrigerated vaccine alarms: low 2°C / high 8°C
    • Frozen vaccine alarms: low -25°C / high -15°C
    • Immediate visual pass/fail indicator
    • Mounted on high-visibility locator card
    • Post-trip evaluation service available
  • Features
    • Compact, single-use temperature logger
    • Shadow Log guarantees trip data
    • No software required for download
    • Built-in USB connector, no special reading device needed
    • On-board software automatically creates PDF and CSV reports in °F and °C
    • View reports on a PC or tablet
    • Recorded data automatically scaled to graph
  • Features
    • Single-use temperature monitor ideal for vaccine transport and storage
    • Monitors and records up to 85 days of data
    • Large, easy to ready LCD display
    • No software required to download data
    • Built-in USB connector, no special reading devices needed
    • Automatically creates secure PDF report and CSV file
    • Trip history statistics available on LCD
    • Patented Shadow Log feature guarantees data even if the shipper fails to start the logger
    • Recorded data automatically scales to graph
  • Features
    • WHO Prequalified E006 Temperature Monitoring Device
    • Compatible with CDC guidelines
    • Ideal for monitoring vaccines and liquid medicines during storage
    • 21 CFR Part 11 compliant software
    • Single channel, external sensor in glycol bottle
    • Glycol buffered sensor emulates products and prevents false alarms
    • Automatically generates PDF, CSV and Daily Log reports
    • Audible and/or visual alarms
    • Low battery indicator on LCD
    • Quick disconnect cable to download logger
    • Easy reset to start a new logging period without using FlashLink software
    • User programmable: manual or auto start, logging intervals, hi/low alarms
    • Scroll through statistics on LCD
  • Features
    • Single channel, external Cryo probe
    • Automatically generates PDF report and CSV file
    • Large easy-to-read LCD
    • Multi-language FlashLink Program Manager software
    • Summary analysis of data, with alarm information
    • Audible and/or visual alarms
    • Degree Minutes and MKT calculations
    • Low battery indicator on LCD
  • Features
    • Monitor vaccines in ultra-low temperatures
    • Ideal for storage and transport with dry ice
    • Compatible with CDC guidelines
    • 21 CFR Part 11 compliant software
    • Single channel, external sensor
    • Automatically generates PDF, CSV and Daily Log reports
    • Audible and/or visual alarms
    • Low battery indicator on LCD
    • Quick disconnect cable to download logger
    • Scroll through recorded data on LCD
  • Features
    • Single-use temperature monitor ideal for vaccine transport and storage
    • Monitors and records up to 85 days of data
    • Large, easy to ready LCD display
    • No software required to download data
    • Built-in USB connector, no special reading devices needed
    • Automatically creates secure PDF report and CSV file
    • Trip history statistics available on LCD
    • Patented Shadow Log feature guarantees data even if the shipper fails to start the logger
    • Recorded data automatically scales to graph
  • Features
    • Single-use, irreversible temperature indicator
    • Monitor refrigerated environments during shipping, storage, handling
    • Immediate visual confirmation of exposure to temperature excursions
    • Easy interpretation of results by receiver or end user
    • Assists with shelf life, quality, and efficacy decisions
    • Identify cold chain problems
  • Features
    • °C/°F selectable
    • 200 mm sharp tip probe
    • Min/Max memory
    • Probe cover with pocket clip on back
    • IP67 waterproof (completely submersible) and grease resistant
    • Continuous min/max temperature recording until the user shuts it off to reset
  • Features
    • Stainless steel
    • Readings in Fahrenheit or Celsius
    • Easy to read
  • Features
    • L series liquid flow switch is used to monitor the flow change
    • Renovated SPDT micro-switch ensure the reliable switch function
    • Max temperature of medium 120°C
    • Liquid pressure up to 1Mpa
    • 3 stainless steel blades for diameter of 25-75mm pipeline
    • 6 additional blades for 100-150mm pipe
    • Protection type IP54
    • Various connections are available on request
    • Max working pressure 13.5Bar
    • Electrical loading AC250V 10A
    • CE approval
  • Features
    • Measurement range from 0 to 19.99 mS/cm
    • Auto-calibration & auto-buffer recognition
    • Automatic temperature compensation
    • IP67 waterproof – tester floats on water for easy retrieval
    • Long sensor life – no need to change sensors
    • Click-lock battery compartment requires no tools for battery replacements
    • Hold function freezes reading temporarily for ease of recording
    • Sensor protective cap that doubles up as a container for samples or calibration solution
Go to Top